<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>12. How does AutoPIPE Vessel handle entry in the "Clad / Overlay Thk" field?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/23701/12-how-does-autopipe-vessel-handle-entry-in-the-clad-overlay-thk-field</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>12. How does AutoPIPE Vessel handle entry in the "Clad / Overlay Thk" field?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/23701/12-how-does-autopipe-vessel-handle-entry-in-the-clad-overlay-thk-field</link><pubDate>Wed, 26 Aug 2020 16:14:04 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:372647bb-e975-4acb-af88-c3911fe2553c</guid><dc:creator>JamieP</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/23701/12-how-does-autopipe-vessel-handle-entry-in-the-clad-overlay-thk-field#comments</comments><description>Current Revision posted to AutoPIPE Wiki by JamieP on 8/26/2020 4:14:04 PM&lt;br /&gt;
&lt;p&gt;&lt;span style="background-color:#008000;color:#ffffff;font-size:150%;"&gt;&lt;strong&gt;Answer:&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;The clad /overlay thickness entered in the Component Properties dialog box is considered as a corrosion allowance.&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;Example, observe that a clad thickness of 5 mm is entered in the&amp;quot;Clad / Overlay Thk&amp;quot; &amp;nbsp;box below.&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/3833.1.png"&gt;&lt;span style="color:#008000;"&gt;&lt;img alt=" " src="/resized-image/__size/720x0/__key/communityserver-wikis-components-files/00-00-00-00-41/3833.1.png" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;The clad thickness is considered as 5 mm corrosion allowance as shown in the report:&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/5482.2.png"&gt;&lt;img alt=" " src="/resized-image/__size/720x0/__key/communityserver-wikis-components-files/00-00-00-00-41/5482.2.png" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: clad thickness, corrosion allowance, AutoPIPE Vessel&lt;/div&gt;
</description></item><item><title>Q. How does AutoPIPE Vessel handle entry in the "Clad / Overlay Thk" field?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/23701/12-how-does-autopipe-vessel-handle-entry-in-the-clad-overlay-thk-field/revision/5</link><pubDate>Fri, 14 Aug 2020 18:34:17 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:372647bb-e975-4acb-af88-c3911fe2553c</guid><dc:creator>JamieP</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/23701/12-how-does-autopipe-vessel-handle-entry-in-the-clad-overlay-thk-field#comments</comments><description>Revision 5 posted to AutoPIPE Wiki by JamieP on 8/14/2020 6:34:17 PM&lt;br /&gt;
&lt;p&gt;&lt;span style="background-color:#008000;color:#ffffff;font-size:150%;"&gt;&lt;strong&gt;Answer:&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;The clad /overlay thickness entered in the Component Properties dialog box is considered as a corrosion allowance.&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;Example, observe that a clad thickness of 5 mm is entered in the&amp;quot;Clad / Overlay Thk&amp;quot; &amp;nbsp;box below.&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/3833.1.png"&gt;&lt;span style="color:#008000;"&gt;&lt;img alt=" " src="/resized-image/__size/720x0/__key/communityserver-wikis-components-files/00-00-00-00-41/3833.1.png" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;The clad thickness is considered as 5 mm corrosion allowance as shown in the report:&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/5482.2.png"&gt;&lt;img alt=" " src="/resized-image/__size/720x0/__key/communityserver-wikis-components-files/00-00-00-00-41/5482.2.png" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: clad thickness, corrosion allowance, AutoPIPE Vessel&lt;/div&gt;
</description></item><item><title>Q. How does AutoPIPE Vessel handle entry in the "Clad / Overlay Thk" field?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/23701/12-how-does-autopipe-vessel-handle-entry-in-the-clad-overlay-thk-field/revision/4</link><pubDate>Wed, 06 Jan 2016 19:54:42 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:372647bb-e975-4acb-af88-c3911fe2553c</guid><dc:creator>Mike Dattilio</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/23701/12-how-does-autopipe-vessel-handle-entry-in-the-clad-overlay-thk-field#comments</comments><description>Revision 4 posted to AutoPIPE Wiki by Mike Dattilio on 1/6/2016 7:54:42 PM&lt;br /&gt;
&lt;p&gt;&lt;span style="font-size:150%;color:#ffffff;background-color:#008000;"&gt;&lt;strong&gt;Answer:&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;The clad /overlay thickness entered in the Component Properties dialog box is considered as a corrosion allowance.&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;Example, observe that a clad thickness of 5 mm is entered in the&amp;quot;Clad / Overlay Thk&amp;quot; &amp;nbsp;box below.&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/3833.1.png"&gt;&lt;span style="color:#008000;"&gt;&lt;img src="/resized-image/__size/720x0/__key/communityserver-wikis-components-files/00-00-00-00-41/3833.1.png" alt=" " /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;The clad thickness is considered as 5 mm corrosion allowance as shown in the report:&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/5482.2.png"&gt;&lt;img src="/resized-image/__size/720x0/__key/communityserver-wikis-components-files/00-00-00-00-41/5482.2.png" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: clad thickness, corrosion allowance, AutoPIPE Vessel&lt;/div&gt;
</description></item><item><title>How does AutoPIPE Vessel handle entry in the "Clad / Overlay Thk" field?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/23701/12-how-does-autopipe-vessel-handle-entry-in-the-clad-overlay-thk-field/revision/3</link><pubDate>Tue, 05 Jan 2016 21:09:32 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:372647bb-e975-4acb-af88-c3911fe2553c</guid><dc:creator>Mike Dattilio</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/23701/12-how-does-autopipe-vessel-handle-entry-in-the-clad-overlay-thk-field#comments</comments><description>Revision 3 posted to AutoPIPE Wiki by Mike Dattilio on 1/5/2016 9:09:32 PM&lt;br /&gt;
&lt;p&gt;&lt;span style="font-size:150%;color:#ffffff;background-color:#008000;"&gt;&lt;strong&gt;Answer:&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;The clad /overlay thickness entered in the Component Properties dialog box is considered as a corrosion allowance.&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;Example, observe that a clad thickness of 5 mm is entered in the&amp;quot;Clad / Overlay Thk&amp;quot; &amp;nbsp;box below.&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/3833.1.png"&gt;&lt;span style="color:#008000;"&gt;&lt;img src="/resized-image/__size/720x0/__key/communityserver-wikis-components-files/00-00-00-00-41/3833.1.png" alt=" " /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;The clad thickness is considered as 5 mm corrosion allowance as shown in the report:&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/5482.2.png"&gt;&lt;img src="/resized-image/__size/720x0/__key/communityserver-wikis-components-files/00-00-00-00-41/5482.2.png" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: clad thickness, corrosion allowance, AutoPIPE Vessel&lt;/div&gt;
</description></item><item><title>How does AutoPIPE Vessel handle entry in the "Clad / Overlay Thk" field?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/23701/12-how-does-autopipe-vessel-handle-entry-in-the-clad-overlay-thk-field/revision/2</link><pubDate>Tue, 17 Nov 2015 00:16:55 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:372647bb-e975-4acb-af88-c3911fe2553c</guid><dc:creator>Sudip Ganguly</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/23701/12-how-does-autopipe-vessel-handle-entry-in-the-clad-overlay-thk-field#comments</comments><description>Revision 2 posted to AutoPIPE Wiki by Sudip Ganguly on 11/17/2015 12:16:55 AM&lt;br /&gt;
&lt;p&gt;Ans: The clad /overlay thickness entered in the Component Properties dialog box is considered as a corrosion allowance.&lt;/p&gt;
&lt;p&gt;Example, observe that a clad thickness of 5 mm is entered in the&amp;quot;Clad / Overlay Thk&amp;quot; &amp;nbsp;box below.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/3833.1.png"&gt;&lt;img src="/resized-image/__size/720x0/__key/communityserver-wikis-components-files/00-00-00-00-41/3833.1.png" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;The clad thickness is considered as 5 mm corrosion allowance as shown in the report:&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/5482.2.png"&gt;&lt;img src="/resized-image/__size/720x0/__key/communityserver-wikis-components-files/00-00-00-00-41/5482.2.png" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: clad thickness, corrosion allowance, AutoPIPE Vessel&lt;/div&gt;
</description></item><item><title>How does AutoPIPE Vessel handle entry in the "Clad / Overlay Thk" field?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/23701/12-how-does-autopipe-vessel-handle-entry-in-the-clad-overlay-thk-field/revision/1</link><pubDate>Mon, 31 Aug 2015 21:54:05 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:372647bb-e975-4acb-af88-c3911fe2553c</guid><dc:creator>Sudip Ganguly</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/23701/12-how-does-autopipe-vessel-handle-entry-in-the-clad-overlay-thk-field#comments</comments><description>Revision 1 posted to AutoPIPE Wiki by Sudip Ganguly on 8/31/2015 9:54:05 PM&lt;br /&gt;
&lt;p&gt;Ans: The clad /overlay thickness entered in the Component Properties dialog box is considered as a corrosion allowance.&lt;/p&gt;
&lt;p&gt;Example, observe that a clad thickness of 5 mm is entered in the&amp;quot;Clad / Overlay Thk&amp;quot; &amp;nbsp;box below.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/3833.1.png"&gt;&lt;img src="/resized-image/__size/720x0/__key/communityserver-wikis-components-files/00-00-00-00-41/3833.1.png" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;The clad thickness is considered as 5 mm corrosion allowance as shown in the report:&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/5482.2.png"&gt;&lt;img src="/resized-image/__size/720x0/__key/communityserver-wikis-components-files/00-00-00-00-41/5482.2.png" alt=" " /&gt;&lt;/a&gt;AurtoPI&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;