<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>28. What is the difference between tubesheet design condition and design case?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/24039/28-what-is-the-difference-between-tubesheet-design-condition-and-design-case</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>28. What is the difference between tubesheet design condition and design case?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/24039/28-what-is-the-difference-between-tubesheet-design-condition-and-design-case</link><pubDate>Mon, 24 Aug 2020 16:52:58 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:8324c696-14ac-4c90-89ed-fea65166f155</guid><dc:creator>JamieP</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/24039/28-what-is-the-difference-between-tubesheet-design-condition-and-design-case#comments</comments><description>Current Revision posted to AutoPIPE Wiki by JamieP on 8/24/2020 4:52:58 PM&lt;br /&gt;
&lt;p&gt;&lt;span style="background-color:#008000;color:#ffffff;font-size:150%;"&gt;Answer: &lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;Design Conditions are generated automatically by the program and also additional design cases can be added by the user in the Tubesheet&amp;gt;Design Conditions tab.&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/41236.1.png"&gt;&lt;span style="color:#008000;"&gt;&lt;img alt=" " src="/resized-image/__size/720x0/__key/communityserver-wikis-components-files/00-00-00-00-41/41236.1.png" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;Design Conditions are possible operating scenarios which the exchanger may experience and hence the design must be performed for that condition eg. there can be an upset condition or shutdown condition when tubeside operating&amp;nbsp;pressure can be 90% of design but shell side pressure would only be 25% of design, this is a special case specific for that exchanger which the designer may expect the exchanger to be operated at in the field.&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;Design Case are a set of cases specified by the code that must be considered for each and every Design Condition eg. for the example above for each of the 5 design conditions 3, 4, 7, 8, 9 there would be 7 cases to be computed as specified by the code, see the tubesheet calculation screenshot from the report below:&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/5516.2.png"&gt;&lt;span style="color:#008000;"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-41/5516.2.png" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;These design cases are automatically calculated by the software for each design condition, if a case is not needed it will not be computed eg. if user check differential pressure then a few relevant cases would not apply and hence not calculated. The above calculation is for fixed tubesheet heat exchanger hence 7 cases are calculated.&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;Observe that the design condition 4 is not there in the above report screenshot menu column in the left, this is because this specific zero tubeside shell side pressure case is automatically taken into account as a specific case for the loading condition 3 (look at case 4 in the report screenshot above).&lt;/span&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: desisng case, AutoPIPE Vessel, tubesheet design, design condition&lt;/div&gt;
</description></item><item><title>28. What is the difference between tubesheet design condition and design case?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/24039/28-what-is-the-difference-between-tubesheet-design-condition-and-design-case/revision/3</link><pubDate>Mon, 24 Aug 2020 16:52:39 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:8324c696-14ac-4c90-89ed-fea65166f155</guid><dc:creator>JamieP</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/24039/28-what-is-the-difference-between-tubesheet-design-condition-and-design-case#comments</comments><description>Revision 3 posted to AutoPIPE Wiki by JamieP on 8/24/2020 4:52:39 PM&lt;br /&gt;
&lt;p&gt;&lt;span style="background-color:#008000;color:#ffffff;font-size:150%;"&gt;Answer: &lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;Design Conditions are generated automatically by the program and also additional design cases can be added by the user in the Tubesheet&amp;gt;Design Conditions tab.&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/41236.1.png"&gt;&lt;span style="color:#008000;"&gt;&lt;img alt=" " src="/resized-image/__size/720x0/__key/communityserver-wikis-components-files/00-00-00-00-41/41236.1.png" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;Design Conditions are possible operating scenarios which the exchanger may experience and hence the design must be performed for that condition eg. there can be an upset condition or shutdown condition when tubeside operating&amp;nbsp;pressure can be 90% of design but shell side pressure would only be 25% of design, this is a special case specific for that exchanger which the designer may expect the exchanger to be operated at in the field.&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;Design Case are a set of cases specified by the code that must be considered for each and every Design Condition eg. for the example above for each of the 5 design conditions 3, 4, 7, 8, 9 there would be 7 cases to be computed as specified by the code, see the tubesheet calculation screenshot from the report below:&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/5516.2.png"&gt;&lt;span style="color:#008000;"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-41/5516.2.png" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;These design cases are automatically calculated by the software for each design condition, if a case is not needed it will not be computed eg. if user check differential pressure then a few relevant cases would not apply and hence not calculated. The above calculation is for fixed tubesheet heat exchanger hence 7 cases are calculated.&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;Observe that the design condition 4 is not there in the above report screenshot menu column in the left, this is because this specific zero tubeside shell side pressure case is automatically taken into account as a specific case for the loading condition 3 (look at case 4 in the report screenshot above).&lt;/span&gt;&lt;/p&gt;
&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: desisng case, AutoPIPE Vessel, tubesheet design, design condition&lt;/div&gt;
</description></item><item><title>Q. What is the difference between tubesheet design condition and design case?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/24039/28-what-is-the-difference-between-tubesheet-design-condition-and-design-case/revision/2</link><pubDate>Wed, 06 Jan 2016 20:44:44 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:8324c696-14ac-4c90-89ed-fea65166f155</guid><dc:creator>Mike Dattilio</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/24039/28-what-is-the-difference-between-tubesheet-design-condition-and-design-case#comments</comments><description>Revision 2 posted to AutoPIPE Wiki by Mike Dattilio on 1/6/2016 8:44:44 PM&lt;br /&gt;
&lt;p&gt;&lt;span style="font-size:150%;color:#ffffff;background-color:#008000;"&gt;Answer: &lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;Design Conditions are generated automatically by the program and also additional design cases can be added by the user in the Tubesheet&amp;gt;Design Conditions tab.&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/41236.1.png"&gt;&lt;span style="color:#008000;"&gt;&lt;img src="/resized-image/__size/720x0/__key/communityserver-wikis-components-files/00-00-00-00-41/41236.1.png" alt=" " /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;Design Conditions are possible operating scenarios which the exchanger may experience and hence the design must be performed for that condition eg. there can be an upset condition or shutdown condition when tubeside operating&amp;nbsp;pressure can be 90% of design but shell side pressure would only be 25% of design, this is a special case specific for that exchanger which the designer may expect the exchanger to be operated at in the field.&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;Design Case are a set of cases specified by the code that must be considered for each and every Design Condition eg. for the example above for each of the 5 design conditions 3, 4, 7, 8, 9 there would be 7 cases to be computed as specified by the code, see the tubesheet calculation screenshot from the report below:&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/5516.2.png"&gt;&lt;span style="color:#008000;"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-41/5516.2.png" alt=" " /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;These design cases are automatically calculated by the software for each design condition, if a case is not needed it will not be computed eg. if user check differential pressure then a few relevant cases would not apply and hence not calculated. The above calculation is for fixed tubesheet heat exchanger hence 7 cases are calculated.&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;Observe that the design condition 4 is not there in the above report screenshot menu column in the left, this is because this specific zero tubeside shell side pressure case is automatically taken into account as a specific case for the loading condition 3 (look at case 4 in the report screenshot above).&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: desisng case, AutoPIPE Vessel, tubesheet design, design condition&lt;/div&gt;
</description></item><item><title>Q. What is the difference between tubesheet design condition and design case?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/24039/28-what-is-the-difference-between-tubesheet-design-condition-and-design-case/revision/1</link><pubDate>Tue, 15 Sep 2015 19:07:35 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:8324c696-14ac-4c90-89ed-fea65166f155</guid><dc:creator>Sudip Ganguly</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/24039/28-what-is-the-difference-between-tubesheet-design-condition-and-design-case#comments</comments><description>Revision 1 posted to AutoPIPE Wiki by Sudip Ganguly on 9/15/2015 7:07:35 PM&lt;br /&gt;
&lt;p&gt;Ans: Design Conditions are generated automatically by the program and also additional design cases can be added by the user in the Tubesheet&amp;gt;Design Conditions tab.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/41236.1.png"&gt;&lt;img src="/resized-image/__size/720x0/__key/communityserver-wikis-components-files/00-00-00-00-41/41236.1.png" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;Design Conditions are possible operating scenarios which the exchanger may experience and hence the design must be performed for that condition eg. there can be an upset condition or shutdown condition when tubeside operating&amp;nbsp;pressure can be 90% of design but shell side pressure would only be 25% of design, this is a special case specific for that exchanger which the designer may expect the exchanger to be operated at in the field.&lt;/p&gt;
&lt;p&gt;Design Case are a set of cases specified by the code that must be considered for each and every Design Condition eg. for the example above for each of the 5 design conditions 3, 4, 7, 8, 9 there would be 7 cases to be computed as specified by the code, see the tubesheet calculation screenshot from the report below:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/5516.2.png"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-41/5516.2.png" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;These design cases are automatically calculated by the software for each design condition, if a case is not needed it will not be computed eg. if user check differential pressure then a few relevant cases would not apply and hence not calculated. The above calculation is for fixed tubesheet heat exchanger hence 7 cases are calculated.&lt;/p&gt;
&lt;p&gt;Observe that the design condition 4 is not there in the above report screenshot menu column in the left, this is because this specific zero tubeside shell side pressure case is automatically taken into account as a specific case for the loading condition 3 (look at case 4 in the report screenshot above).&lt;/p&gt;