<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>23. Can you specify different temperature zones for a vessel in AutoPIPE Vessel?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/24120/23-can-you-specify-different-temperature-zones-for-a-vessel-in-autopipe-vessel</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>23. Can you specify different temperature zones for a vessel in AutoPIPE Vessel?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/24120/23-can-you-specify-different-temperature-zones-for-a-vessel-in-autopipe-vessel</link><pubDate>Wed, 19 Aug 2020 21:23:09 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:f601ed47-0d1b-4c9f-8ad8-4e4db1f68f11</guid><dc:creator>JamieP</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/24120/23-can-you-specify-different-temperature-zones-for-a-vessel-in-autopipe-vessel#comments</comments><description>Current Revision posted to AutoPIPE Wiki by JamieP on 8/19/2020 9:23:09 PM&lt;br /&gt;
&lt;p&gt;&lt;strong&gt;&lt;span style="background-color:#008000;color:#ffffff;font-size:150%;"&gt;Answer:&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;Yes, this can be done by first splitting the vessel into the number of different temperature zones by split shell command:&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/768188.1.png"&gt;&lt;span style="color:#008000;"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-41/768188.1.png" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;Once the shell is split, open the shell where you want to set a specific design temperature, then in the materials tab, under the design sub-tab, input the design temperature eg. 250C, then click on Update Properties:&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/6472.4.png"&gt;&lt;span style="color:#008000;"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-41/6472.4.png" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;Observe that the Properties got updated for 250C.&lt;/span&gt;&lt;/p&gt;
&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AutoPIPE Vessel, different temperature zone, design temperature&lt;/div&gt;
</description></item><item><title>Q. Can you specify different temperature zones for a vessel in AutoPIPE Vessel?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/24120/23-can-you-specify-different-temperature-zones-for-a-vessel-in-autopipe-vessel/revision/3</link><pubDate>Wed, 06 Jan 2016 17:57:54 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:f601ed47-0d1b-4c9f-8ad8-4e4db1f68f11</guid><dc:creator>Mike Dattilio</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/24120/23-can-you-specify-different-temperature-zones-for-a-vessel-in-autopipe-vessel#comments</comments><description>Revision 3 posted to AutoPIPE Wiki by Mike Dattilio on 1/6/2016 5:57:54 PM&lt;br /&gt;
&lt;p&gt;&lt;strong&gt;&lt;span style="font-size:150%;color:#ffffff;background-color:#008000;"&gt;Answer:&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;Yes, this can be done by first splitting the vessel into the number of different temperature zones by split shell command:&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/768188.1.png"&gt;&lt;span style="color:#008000;"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-41/768188.1.png" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;Once the shell is split, open the shell where you want to set a specific design temperature, then in the materials tab, under the design sub-tab, input the design temperature eg. 250C, then click on Update Properties:&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/6472.4.png"&gt;&lt;span style="color:#008000;"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-41/6472.4.png" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;Observe that the Properties got updated for 250C.&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AutoPIPE Vessel, different temperature zone, design temperature&lt;/div&gt;
</description></item><item><title>Design Temperature zones</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/24120/23-can-you-specify-different-temperature-zones-for-a-vessel-in-autopipe-vessel/revision/2</link><pubDate>Mon, 21 Sep 2015 17:51:32 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:f601ed47-0d1b-4c9f-8ad8-4e4db1f68f11</guid><dc:creator>Sudip Ganguly</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/24120/23-can-you-specify-different-temperature-zones-for-a-vessel-in-autopipe-vessel#comments</comments><description>Revision 2 posted to AutoPIPE Wiki by Sudip Ganguly on 9/21/2015 5:51:32 PM&lt;br /&gt;
&lt;p&gt;Q. Can you specify different temperature zones for a vessel in AutoPIPE Vessel?&lt;/p&gt;
&lt;p&gt;Ans; Yes, this can be done by first splitting the vessel into the number of different temperature zones by split shell command:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/768188.1.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-41/768188.1.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;Once the shell is split, open the shell where you want to set a specific design temperature, then in the materials tab, under the design sub-tab, input the design temperature eg. 250C, then click on Update Properties:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/6472.4.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-41/6472.4.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;Observe that the Properties got updated for 250C.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AutoPIPE Vessel, different temperature zone, design temperature&lt;/div&gt;
</description></item><item><title>Design Temperature zones</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/24120/23-can-you-specify-different-temperature-zones-for-a-vessel-in-autopipe-vessel/revision/1</link><pubDate>Mon, 21 Sep 2015 17:47:32 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:f601ed47-0d1b-4c9f-8ad8-4e4db1f68f11</guid><dc:creator>Sudip Ganguly</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/24120/23-can-you-specify-different-temperature-zones-for-a-vessel-in-autopipe-vessel#comments</comments><description>Revision 1 posted to AutoPIPE Wiki by Sudip Ganguly on 9/21/2015 5:47:32 PM&lt;br /&gt;
&lt;p&gt;Q. Can you specify different temperature zones for a vessel in AutoPIPE Vessel?&lt;/p&gt;
&lt;p&gt;Ans; Yes, this can be done by first splitting the vessel into the number of different temperature zones by split shell command:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/768188.1.png"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-41/768188.1.png" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;Once the shell is split, open the shell where you want to set a specific design temperature, then in the materials tab, under the design sub-tab, input the design temperature eg. 250C, then click on Update Properties:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/6472.4.png"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-41/6472.4.png" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;Observe that the Properties got updated for 250C.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AutoPIPE Vessel, different temperature zone, design temperature&lt;/div&gt;
</description></item></channel></rss>