<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>10. On selecting a shell component and in the materials tab when clicking on OK, the length becomes 0. How do I resolve this?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/24419/10-on-selecting-a-shell-component-and-in-the-materials-tab-when-clicking-on-ok-the-length-becomes-0-how-do-i-resolve-this</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>10. On selecting a shell component and in the materials tab when clicking on OK, the length becomes 0. How do I resolve this?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/24419/10-on-selecting-a-shell-component-and-in-the-materials-tab-when-clicking-on-ok-the-length-becomes-0-how-do-i-resolve-this</link><pubDate>Tue, 25 Aug 2020 19:48:42 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:53b1944e-687c-4051-804a-aa50c44d280b</guid><dc:creator>JamieP</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/24419/10-on-selecting-a-shell-component-and-in-the-materials-tab-when-clicking-on-ok-the-length-becomes-0-how-do-i-resolve-this#comments</comments><description>Current Revision posted to AutoPIPE Wiki by JamieP on 8/25/2020 7:48:42 PM&lt;br /&gt;
&lt;h3&gt;&lt;span style="background-color:#ffffff;"&gt;&lt;strong&gt;&lt;span style="color:#993300;"&gt;Question&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/h3&gt;
&lt;p style="margin-left:30px;"&gt;On selecting a shell component and in the materials tab when clicking on OK, the length becomes 0. How do I resolve this?&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/18687.1.png"&gt;&lt;img alt=" " src="/resized-image/__size/720x0/__key/communityserver-wikis-components-files/00-00-00-00-41/18687.1.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/1641.2.png"&gt;&lt;img alt=" " src="/resized-image/__size/720x0/__key/communityserver-wikis-components-files/00-00-00-00-41/1641.2.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;How do I resolve this?&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="background-color:#008000;color:#ffffff;font-size:150%;"&gt;&lt;strong&gt;Answer:&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="color:#008000;"&gt;Double click on the&amp;nbsp;shell whose length has become 0, if you are unable to open it because the length is collapsed to 0, you may select it from the left&amp;nbsp;side item list and double click.&amp;nbsp;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:150px;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/5857.5.png"&gt;&lt;span style="color:#008000;"&gt;&lt;img alt=" " src="/resized-image/__size/720x0/__key/communityserver-wikis-components-files/00-00-00-00-41/5857.5.png" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="color:#008000;"&gt;Open the material tab.&amp;nbsp;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="color:#008000;"&gt;Observe that the Chamber&amp;nbsp;No. under the material&amp;nbsp;tab for the shell &amp;nbsp;is &amp;#39;1&amp;#39;.&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:150px;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/3113.3.png"&gt;&lt;span style="color:#008000;"&gt;&lt;img alt=" " src="/resized-image/__size/720x0/__key/communityserver-wikis-components-files/00-00-00-00-41/3113.3.png" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="color:#008000;"&gt;This is incorrect since the Chamber No. should be &amp;#39;2&amp;#39; as this is tubeside component and tubeside component is chamber no. &amp;#39;2&amp;#39;, the shellside is chamber no. &amp;#39;1&amp;#39;.&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="color:#008000;"&gt;Change this to 2 and click OK.&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="color:#008000;"&gt;The problem should get resolved:&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:150px;"&gt;&lt;span style="color:#008000;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/6763.6.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-41/6763.6.png" /&gt;&lt;/a&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AutoPIPE Vessel, shell vanishes, length is zero, Component&lt;/div&gt;
</description></item><item><title>Q. On selecting a shell component and in the materials tab when clicking on OK, the length becomes 0. How do I resolve this?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/24419/10-on-selecting-a-shell-component-and-in-the-materials-tab-when-clicking-on-ok-the-length-becomes-0-how-do-i-resolve-this/revision/2</link><pubDate>Wed, 06 Jan 2016 19:47:10 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:53b1944e-687c-4051-804a-aa50c44d280b</guid><dc:creator>Mike Dattilio</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/24419/10-on-selecting-a-shell-component-and-in-the-materials-tab-when-clicking-on-ok-the-length-becomes-0-how-do-i-resolve-this#comments</comments><description>Revision 2 posted to AutoPIPE Wiki by Mike Dattilio on 1/6/2016 7:47:10 PM&lt;br /&gt;
&lt;h3&gt;&lt;span style="background-color:#ffffff;"&gt;&lt;strong&gt;&lt;span style="color:#993300;"&gt;Question&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/h3&gt;
&lt;p style="margin-left:30px;"&gt;On selecting a shell component and in the materials tab when clicking on OK, the length becomes 0. How do I resolve this?&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/18687.1.png"&gt;&lt;img src="/resized-image/__size/720x0/__key/communityserver-wikis-components-files/00-00-00-00-41/18687.1.png" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/1641.2.png"&gt;&lt;img src="/resized-image/__size/720x0/__key/communityserver-wikis-components-files/00-00-00-00-41/1641.2.png" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;How do I resolve this?&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="font-size:150%;color:#ffffff;background-color:#008000;"&gt;&lt;strong&gt;Answer:&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="color:#008000;"&gt;Double click on the&amp;nbsp;shell whose length has become 0, if you are unable to open it because the length is collapsed to 0, you may select it from the left&amp;nbsp;side item list and double click.&amp;nbsp;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:150px;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/5857.5.png"&gt;&lt;span style="color:#008000;"&gt;&lt;img src="/resized-image/__size/720x0/__key/communityserver-wikis-components-files/00-00-00-00-41/5857.5.png" alt=" " /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="color:#008000;"&gt;Open the material tab.&amp;nbsp;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="color:#008000;"&gt;Observe that the Chamber&amp;nbsp;No. under the material&amp;nbsp;tab for the shell &amp;nbsp;is &amp;#39;1&amp;#39;.&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:150px;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/3113.3.png"&gt;&lt;span style="color:#008000;"&gt;&lt;img src="/resized-image/__size/720x0/__key/communityserver-wikis-components-files/00-00-00-00-41/3113.3.png" alt=" " /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="color:#008000;"&gt;This is incorrect since the Chamber No. should be &amp;#39;2&amp;#39; as this is tubeside component and tubeside component is chamber no. &amp;#39;2&amp;#39;, the shellside is chamber no. &amp;#39;1&amp;#39;.&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="color:#008000;"&gt;Change this to 2 and click OK.&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="color:#008000;"&gt;The problem should get resolved:&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:150px;"&gt;&lt;span style="color:#008000;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/6763.6.png"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-41/6763.6.png" alt=" " /&gt;&lt;/a&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AutoPIPE Vessel, shell vanishes, length is zero, Component&lt;/div&gt;
</description></item><item><title>Shell length disappears</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/24419/10-on-selecting-a-shell-component-and-in-the-materials-tab-when-clicking-on-ok-the-length-becomes-0-how-do-i-resolve-this/revision/1</link><pubDate>Thu, 01 Oct 2015 23:10:16 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:53b1944e-687c-4051-804a-aa50c44d280b</guid><dc:creator>Sudip Ganguly</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/24419/10-on-selecting-a-shell-component-and-in-the-materials-tab-when-clicking-on-ok-the-length-becomes-0-how-do-i-resolve-this#comments</comments><description>Revision 1 posted to AutoPIPE Wiki by Sudip Ganguly on 10/1/2015 11:10:16 PM&lt;br /&gt;
&lt;p&gt;Q. On selecting a shell component and in the materials tab when I click on OK, the length becomes 0.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/18687.1.png"&gt;&lt;img src="/resized-image/__size/720x0/__key/communityserver-wikis-components-files/00-00-00-00-41/18687.1.png" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/1641.2.png"&gt;&lt;img src="/resized-image/__size/720x0/__key/communityserver-wikis-components-files/00-00-00-00-41/1641.2.png" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;How do I resolve this?&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Ans: Double click on the&amp;nbsp;shell whose length has become 0, if you are unable to open it because the length is collapsed to 0, you may select it from the left&amp;nbsp;side item list and double click.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/5857.5.png"&gt;&lt;img src="/resized-image/__size/720x0/__key/communityserver-wikis-components-files/00-00-00-00-41/5857.5.png" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Open the material tab.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Observe that the Chamber&amp;nbsp;No. under the material&amp;nbsp;tab for the shell &amp;nbsp;is &amp;#39;1&amp;#39;.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/3113.3.png"&gt;&lt;img src="/resized-image/__size/720x0/__key/communityserver-wikis-components-files/00-00-00-00-41/3113.3.png" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;This is incorrect since the Chamber No. should be &amp;#39;2&amp;#39; as this is tubeside component and tubeside component is chamber no. &amp;#39;2&amp;#39;, the shellside is chamber no. &amp;#39;1&amp;#39;.&lt;/p&gt;
&lt;p&gt;Change this to 2 and click OK. &lt;/p&gt;
&lt;p&gt;The problem should get resolved:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/6763.6.png"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-41/6763.6.png" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;