For the given model with the specify load harmonic load case shown here:
Why we see no displacement at the node where an AutoPIPE Harmonic load is imposed in the same direction?
I would expect to see displacement of Dx = 0.59 at A02, instead it is shown as 0.00 in, why?
The reason is based on the Harmonic Dynamic Analysis settings change the Combination method from RMS to MAX and include both ZPA and Missing Mass options, as shown here: