Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
  • Welcome
  • Products
  • Support
  • About
  • More
  • Cancel
AutoPIPE
  • Product Communities
  • More
AutoPIPE
AutoPIPE Wiki AutoPIPE CONNECT Release Notes (10.00.00.10)
    • Sign in
    • -Pipe and Vessel Stress Analysis - Wiki
      • +ADL PIPE
      • -Bentley AutoPIPE
        • ++Table Of Contents - AutoPIPE Wiki page
        • +- General Information about AutoPIPE
        • +-NEW User Guide - TIPs - FAQ - RSS Newsfeed - AutoPIPE
        • +ATS and Batch Processing - AutoPIPE
        • AutoPIPE QA&R program
        • -Download - Install - Release Notes - AutoPIPE
          • -01. Bentley AutoPIPE Release Notes
            • -01a. AutoPIPE CONNECT Release Notes (10.00.xx.xx - higher)
              • -AutoPIPE CONNECT Release Notes (10.00.00.10)
                • AutoPIPE CONNECT Readme File (10.00.00.10)
              • +AutoPIPE CONNECT Release Notes (10.01.00.05)
              • +AutoPIPE CONNECT Release Notes (10.01.00.08)
              • +AutoPIPE CONNECT Release Notes (10.01.00.09)
              • +AutoPIPE CONNECT Release Notes (11.00.00.22)
              • +AutoPIPE CONNECT Release Notes (11.01.00.17)
              • +AutoPIPE CONNECT Release Notes (11.01.00.23)
              • AutoPIPE CONNECT Release Notes (11.01.00.24)
              • +AutoPIPE CONNECT Release Notes (11.02.00.08)
              • +AutoPIPE CONNECT Release Notes (11.02.00.10)
              • +AutoPIPE CONNECT Release Notes (11.03.00.08)
              • +AutoPIPE CONNECT Release Notes (11.04.00.10)
              • +AutoPIPE CONNECT Release Notes (12.00.00.14)
              • +AutoPIPE CONNECT Release Notes (12.00.00.16)
              • +AutoPIPE CONNECT Release Notes (12.01.00.09)
              • +AutoPIPE CONNECT Release Notes (12.01.00.10)
              • +AutoPIPE CONNECT Release Notes (12.02.00.14)
              • +AutoPIPE CONNECT Release Notes (12.03.00.17)
              • +AutoPIPE CONNECT Release Notes (12.04.00.13)
              • +AutoPIPE CONNECT Release Notes (12.04.00.14)
              • +AutoPIPE CONNECT Release Notes (12.05.00.16)
            • +01b. AutoPIPE V8i Release Notes (09.01.xx.xx - 09.06.xx.xx)
            • +01c. AutoPIPE XM Release Notes (08.09.xx.xx - 09.00.xx.xx)
            • +01d. AutoPIPE 2004 Release Notes (08.05.xx.xx - 08.06.xx.xx):
            • +01e. AutoPIPE 6 Release Notes (06.xx.xx)
            • 01f. AutoPIPE 05.00.11 Release Notes
            • +02a. AutoPIPE Automatic Test Set (ATS) Release Notes:
            • 04. Understanding Software Version Number Format for AutoPIPE and AutoPIPE vessel
            • Bentley AutoPIPE software notification options:
          • +02. How do I download, install, and license AutoPIPE?
          • +03. How do I Install, License, and Run AutoPIPE ATS (Automatic Test Set)?
          • 04. Installing AutoPIPE on an untested Operating System
          • +05. Hardware Related Issues - AutoPIPE
          • +06. Performing a silent installation - AutoPIPE
          • 07. Install multiple versions of AutoPIPE on the same computer
          • 09. For AutoPIPE V8i 09.05.xx.xx and lower install Bentley IEG First
          • 10. Re-associate AutoPIPE's *.DAT file extension to execute the program when double selected
          • 11. Installing and running AutoPIPE on a computer with MS Bitlocker
          • 12. Does AutoPIPE V8i rely on any external software like ActiveX, Java, Adobe Flash, dynamic link libraries etc?
          • 13. Installing AutoPIPE with AutoPLANT
          • 14. Performing a clean installation - AutoPIPE
          • 15. Re-installing AutoPIPE on a computer that needs to get rebuilt
          • 17. Updating AutoPIPE software
          • 18. Can AutoPIPE be deployed on a server to be accessed on any client machine through application or desktop virtualization ?
          • 19. How to uninstall AutoPIPE from my computer?
          • 20. AutoPIPE's installation folder is locked out or read-only?
          • 20. How to set file association when installing OPIM ?
          • 21. Can I install AutoPIPE on a VM (Virtual Machine)?
          • +22. How to install a patch sent by Bentley AutoPIPE development team?
          • How to be notified when a new version of AutoPIPE has been released?
        • +File / Model Management using AutoPIPE
        • +General - AutoPIPE
        • +Graphics - AutoPIPE
        • +Grids (Input & Results) - AutoPIPE
        • +Import and Export - AutoPIPE
        • +Known Issues in AutoPIPE (Enhancements, defects, etc..)
        • +Libraries - AutoPIPE
        • +License AutoPIPE -
        • +Loads and Load Sets - AutoPIPE
        • +Localization (Non-English Language) - AutoPIPE
        • +Modeling Approaches in AutoPIPE
        • +Modules (i.e. Flange Analysis, Spring Hanger Selection, Rotating Equip, TTA) in AutoPIPE
        • +Piping codes - AutoPIPE
        • +Post Processing - AutoPIPE
        • +Printing - AutoPIPE
        • +Reports - AutoPIPE
        • +Settings - AutoPIPE
        • +Stress Isometrics - AutoPIPE
        • +Technology Productivity Capabilities
        • +Warnings, Errors, Crashed, Confirm, etc.. messages in AutoPIPE
        • +~ Technical Support - AutoPIPE
      • +Bentley AutoPIPE Nozzle (WinNOZL)
      • +Bentley AutoPIPE Vessel (powered by Microprotol)
      • +Bentley PlantFLOW
      • +Bentley PULS
    • Multi-lingual announcement from BENTLEY TECHNICAL SUPPORT.
    • +Training - Webinar - Help
    • Working at Home with AutoPIPE
    • +~ Attend a live meeting with an AutoPIPE Analyst

     
     Questions about this article, topic, or product? Click here. 

    AutoPIPE CONNECT Release Notes (10.00.00.10)

    Applies To
    Product(s): AutoPIPE
    Version(s): CONNECT
    Area: Install
    Original Author: Bentley Technical Support Group
    Date Logged
    & Current Version
    Oct. 2015
    10.00.00.10

    Date Posted:      10/20/2015 2:21:25 PM 

    Platforms:

    Windows 7
    Windows 7 x64
    Windows 8
    Windows 8 x64
    Windows 10
    Windows 10 x64                             

    Languages:       English

    Note:                  Bentley IEG License Service is NOT required to run this AutoPIPE version.

    Description:

    Bentley AutoPIPE CONNECT Edition (v10.00.00.10) - English

    Bentley AutoPIPE CONNECT Edition is a stand-alone, engineering application for the calculation of piping stresses, fatigue stresses, fluid transient, bowing or thermal transient analysis, flange or pipe support design, and equipment nozzle loading analysis under static and dynamic loading conditions. In addition to 30+ piping codes, AutoPIPE incorporates ASME, JSME, British Standard, European, API, NEMA, ANSI, ASCE, AISC, UBC, GOST and WRC guidelines and design limits to provide a comprehensive analysis of the entire system.

    This new release provides new features, critical code updates, and enhanced product interoperability. This is a product generation update for AutoPIPE V8i (v09.06.02.06) which includes several bug fixes plus the following new features:

    Fixes:                  197 Enhancements and Errors were completed

    Piping Code Updates

    • ASME B31.3-2014
    • ASME B31.4 Offshore 2012 Edition
    • ASME B31.8 2014 Edition (Onshore and Offshore)
    • CSA-Z662 2011 Edition (including Offshore)
    • CSA-Z662 2015 Edition (including Offshore)
    • Apply ASME CC N755-1 rules to B31.4 Onshore and B31.8 Onshore
    • Seven new materials added to the ASME 2013 material library 
      • (SA-672 Gr.C60, SA-672 Gr.C70, SA-134 Gr.A283D, SA-234 Gr.WPC, SA-234 Gr.WP11, SA-403 Gr.WP316L and SA-182 Gr.F316L)

    Import / Export

    • AutoPIPE Isometrics Manager can now export angle valves, base elbow supports, and reference items
    • XML export to be imported to plant design software like PDMS

    Modeling

    • Automatic syncing of node and support IDs for increased model organization

    Analysis

    • Local Incidental Pressure Calculation (used for offshore riser piping) available for all piping codes
    • Option to apply pressure correction factor to user-defined SIF and Flexibility factor values
    • ASME NB: Use local tee axis for tee moment summation for ASME III Class 1 piping
    • Report inconsistent non-linear code and non-code combinations to ensure proper pipe stress analysis
    • Write out "Pressure Extension" in Analysis Set Dialog

    Reports

    • Results Database are now compatible with Office 2013
    • Add User SIF note to Flange, Tee, and Valve Data Listing sub-report
    • SQLite Database Export [ Technology Preview ]  (TFS-E263788)
    • SQLite Custom Report Manager [ Technology Preview ] (TFS-E333694)
    • Microsoft Word Input Listing Reports [ Technology Preview ]  (TFS-E241245)

    General

    • Bentley CONNECT Project Selection dialog added for increased workflow visibility for your entire project team
    • Unchecking the "Show rotation report" check-box will be retained for the entire AutoPIPE session
    • Improved workspace and user profile management per Windows guidelines
    • Warning message for pipes using the ADLPipe default fatigue curve that have a 1E6 cycle limit
    • Warning message added to ASME B31.4 (2012) to display when selected material does not have yield strength values

    Documentation

    • Improved help content for DNV 2012 legacy combinations and usage
    • Updated ASME BPV-III-1-NB (1972-2013) flow chart in help
    • Added help content for CSA-Z662 Thermal Expansion with effects of "Include axial force"

     Technology Previews provide users preliminary access to features currently in development but not yet ready for production. These features are provided at no additional charge to promote awareness of a feature or technology to be deployed in a future release. Users are encouraged to provide feedback and suggestions. Please log a Service Request naming which Technology Preview feature you like to enable in AutoPIPE.

    Select the following link: 

    • See the DETAILED Readme file

      Note: the read me file contains limited amount of data about errors / enhancements, only QA&R members have access to detailed Error Reports

    • See procedure for Installing AutoPIPE CONNECT 10.00.00.10 (different version but same process)

    Installed with AutoPIPE:

    AutoPIPE Preview Handler

    01.01.04
    Bentley AutoPIPE CONNECT 10.00.00.10
    Bentley AutoPIPE CONNECT Setup 10.00.00.10
    Bentley AutoPIPE Nozzle V8i 08.11.08.24
    Bentley STRAIT to AutoPIPE Translator 06.00.00.15
    Bentley PCF to AutoPIPE Translator 01.00.00.42
    Bentley ADLPipe to AutoPIPE Translator 01.00.00.21
    Bentley AutoPIPE Batch File Generator 01.00.00.01
    Connection Client 10.00.01.11
    OPIM (Open Plant Isometric Manager)

    08.11.09.564

    08.11.09.574 (Jan 2016)

    See Also

    Release Notes- Connect Edition

    Bentley AutoPIPE

    • CONNECT Edition
    • New and Changed
    • AutoPIPE
    • release notes
    • 10.00.00.10
    • Share
    • History
    • More
    • Cancel
    • Mike Dattilio Created by Bentley Colleague Mike Dattilio
    • When: Tue, Oct 20 2015 12:08 PM
    • Mike Dattilio Last revision by Bentley Colleague Mike Dattilio
    • When: Mon, Jun 22 2020 6:19 PM
    • Revisions: 51
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2021 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies