The following message appears in AutoPIPE:
---------------------------Warning--------------------------- W97-99: No analyzed pressure cases present. Only axial GR stress is added.---------------------------OK ---------------------------
Why and how to avoid it?
As the message indicates that the analysis set(s) does not have an active pressure case.
Select one of the following options:
a. Turn OFF the following setting:
Tools> Model Options> Results> Include Axial, Pcase in Sustained
or
b. If "Include Axial, Pcase in Sustained"is enabled, then for at least one Static Analysis Set enable the following feature: "Pressure Ext." also known as "Calculate pressure extension cases, e.g. P1, P2, etc". This feature is located under Load> Static Analysis Set> .
"Warnings" Messages
Bentley AutoPIPE