Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
AutoPIPE
  • Product Communities
AutoPIPE
AutoPIPE Wiki Q. Confirm - Code / Non-code combinations with unanalyzed load cases were found. in AutoPIPE reports, why?
    • Sign In
    • -Pipe and Vessel Stress Analysis - Wiki
      • +ADL PIPE
      • -Bentley AutoPIPE
        • +- General Information about AutoPIPE
        • +- NEW User Guide for AutoPIPE
        • +- Technical Support - AutoPIPE
        • +Batch Processing, ITS, and ATS using AutoPIPE
        • AutoPIPE QA&R program
        • +Download - Install - Release Notes - AutoPIPE
        • +File / Model Management using AutoPIPE
        • +General - AutoPIPE
        • +Graphics - AutoPIPE
        • +Grids (Input & Results) - AutoPIPE
        • +Import and Export - AutoPIPE
        • +Known Issues in AutoPIPE (Enhancements, defects, etc..)
        • +Libraries - AutoPIPE
        • +License AutoPIPE -
        • +Loads and Load Sets - AutoPIPE
        • +Localization (Non-English Language) - AutoPIPE
        • +Modeling Approaches in AutoPIPE
        • +Modules (i.e. Flange Analysis, Spring Hanger Selection, Rotating Equip, TTA) in AutoPIPE
        • +Piping codes - AutoPIPE
        • +Post Processing - AutoPIPE
        • +Printing - AutoPIPE
        • +Reports - AutoPIPE
        • Security
        • +Settings - AutoPIPE
        • +Stress Isometrics - AutoPIPE
        • +Technology Productivity Capabilities
        • -Warnings, Errors, Crashed, Confirm, etc.. messages in AutoPIPE
          • "1 Interrupted Action" messages displayed while coping AutoPIPE file, why?
          • +"Alert" Messages displayed in AutoPIPE
          • +"AutoPIPE Licensing" Messages displayed in AutoPIPE
          • +"Autopipe.exe" Messages displayed in AutoPIPE
          • +"Beam Section" Messages displayed in AutoPIPE
          • +"Bentley AutoPIPE" Messages displayed in AutoPIPE
          • +"Bentley Systems, Inc" Messages displayed in AutoPIPE
          • "Bentley.lictransmit for Windows has stopped working" message appears when using AutoPIPE program, why?
          • +"Blank" Messages displayed in AutoPIPE
          • +"Bolts*" Messages displayed in AutoPIPE
          • -"Confirm" Messages displayed in AutoPIPE
            • Q. Confirm - Renumber does not affect external files. Are you sure you want to continue?....message in AutoPIPE
            • Q. Confirm - This model may be affected by a previous program defect.... message in AutoPIPE
            • Q. Confirm - Code / Non-code combinations with unanalyzed load cases were found. in AutoPIPE reports, why?
            • Q. Confirm - Current model revision does not match analysis result(s) below....message in AutoPIPE
            • Q. Confirm - Import Process successful. Review Warning message... message appears when importing a file into AutoPIPE
            • Q. Confirm - No range has been selected. Do you want to export the complete model? message appears in AutoPIPE, why and how to avoid?
            • +Q. Confirm - The load case did not converge. Do you wish to continue iterating? ... message in AutoPIPE
            • Q. Confirm - The model you are about to open was last modified in a newer version of the product ....message in AutoPIPE
            • Q. Confirm - Unable to update model "name" data files on the disk. message appears in AutoPIPE
            • Q. Large coordinates >1.0E+6 are detected in the PCF file... message was displayed when importing a model in AutoPIPE, why?
          • +"Error" messages displayed in AutoPIPE
          • +"Flange*" Messages displayed in AutoPIPE
          • +"Incorrect Data" messages displayed in AutoPIPE
          • +"Intel(r) Visual Fortran run-time error" messages displayed in AutoPIPE
          • +"Invalid Format" messages displayed in AutoPIPE
          • +"License Management Tool" Messages displayed in AutoPIPE
          • "Message from SofTrack" Messages displayed in AutoPIPE
          • +"Microsoft .NET Framework".. messages displayed in AutoPIPE
          • "Microsoft Visual C++ Runtime Library" message appears in AutoPIPE
          • "New Case Failed" Messages displayed in AutoPIPE
          • +"Note" Messages in AutoPIPE
          • +"PCFin" Messages displayed in AutoPIPE
          • +"Report Generator Error" Messages displayed in AutoPIPE
          • +"Reverse Segment" Messages displayed in AutoPIPE
          • +"SACS Export Error" messages displayed in AutoPIPE
          • +"Script Error" messages displayed in AutoPIPE
          • +"Text Node Editor" Messages displayed in when using OPIM from within AutoPIPE
          • "Unable to Import the Excel File..." Messages displayed in AutoPIPE
          • +"Warnings" Messages displayed in AutoPIPE
          • +Application Crashed or Freezes - AutoPIPE
          • AutoPIPE Report Viewer has stopped working
          • +Blank Messages displayed in AutoPIPE
          • +Issues that occur when exporting files from AutoPIPE
          • +Issues that occur when generating Reports from AutoPIPE
          • +Issues that occur when importing PXF files into AutoPIPE
          • +Known errors that occur when Installing / Uninstalling AutoPIPE
      • +Bentley AutoPIPE Nozzle (WinNOZL)
      • +Bentley AutoPIPE Vessel (powered by Microprotol)
      • +Bentley PlantFLOW
      • +Bentley PULS
    • Multi-lingual announcement from BENTLEY TECHNICAL SUPPORT.
    • Working at Home with AutoPIPE
    • +AutoPIPE Brand Learning Resources
    • +Attend a live meeting with an AutoPIPE Analyst

     
     Questions about this article, topic, or product? Click here. 

    Q. Confirm - Code / Non-code combinations with unanalyzed load cases were found. in AutoPIPE reports, why?

    Applies To
    Product(s): AutoPIPE
    Version(s): 2004, XM, V8i, CONNECT;
    Area: Message
    Original Author: Bentley Technical Support Group
    Date Logged
    & Current Version
    Oct. 2015
    10.00.00.10

    Problem:

    The following confirm message was displayed in AutoPIPE:

     


    ---------------------------
    Confirm
    ---------------------------
    Code combinations with unanalyzed load cases were found. The results
    for these combinations will not be complete. To see additional details,
    see the Analysis Summary report (Result/Output Report). Would you like
    to deactivate all code combinations with unanalyzed load cases?
    ---------------------------
    Yes No Cancel
    ---------------------------

    ---------------------------
    Confirm
    ---------------------------
    Non-Code combinations with unanalyzed load cases were found. The results
    for these combinations will not be complete. To see additional details,
    see the Analysis Summary report (Result/Output Report). Would you like
    to deactivate all non-code combinations with unanalyzed load cases?
    ---------------------------
    Yes No Cancel
    ---------------------------

     

    Solution:

     As mentioned in the message, review the Results> Output report> Analysis Summary report in its entirety.

    See example:

    Some of the combinations have * or ** at the beginning, which is referring to the foot notes at the bottom of the page:

    * indicates that the load case has not been analyzed

    ** indicates that the combination includes unanalyzed load case(s)
    or combination(s) that include unanalyzed load case(s).

     Considering the example image above, note that Combination Description = Occasional is comprised of the following load cases: Sustained and R22 (see Case / Combination column from the report). Note that the R22 load case has a * at the start of the load case name. This is referring the reader that to the following foot note: "indicates that the load case has not been analyzed".

    Therefore, go back into AutoPIPE and review the Static and Dynamic load set settings. Note that the indicated load cases (ex: R22, U21, and R12) have not been analyzed or been deleted from the model.

    Avoidance:

    See the Analysis Summary report to determine which combinations and ultimately which load cases have not been analyze. Choose of of the following:

    1. Adjust the Static or Dynamic Analysis set settings to include the offending load case(s) in the analysis.

    or 

    2. Modify the combination to remove all analyzed load case(s) from analyzed combinations.

    See Also

    Confirm Messages displayed in AutoPIPE

    Bentley AutoPIPE

    • Unanalyzed Load Case
    • AutoPIPE
    • message
    • Confirm
    • Share
    • History
    • More
    • Cancel
    • Mike Dattilio Created by Bentley Colleague Mike Dattilio
    • When: Mon, Nov 2 2015 2:56 PM
    • Mike Dattilio Last revision by Bentley Colleague Mike Dattilio
    • When: Wed, Dec 18 2019 10:05 AM
    • Revisions: 6
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies