The thermal expansion for a model is based off the temperature difference between the Load Case temp and the ambient temp. Therefore, if ambient was 70F and the Load Case temp was 100F, the thermal expansion (and thus thermal load) would be based of 30F difference.
The thermal expansion in code compliance is based on the moment calculations of the corresponding load case (e.g. Amb to T1). These moment values are provided in the Forces and Moments report and represent the difference between operating and ambient temperature. If a separate combination exists that compares two operating load cases (e.g. T1 to T2), the temperature difference shall be between T1 and T2.
The axial force in code compliance is taken from the axial force evaluated during analysis of the model.
AutoPIPE thermal expansion is calculated using the equation found in the link here.
Question: are the pressures in gauge or absolute value?
Answer: Open AutoPIPE model, select a pipe run, open Operating Pressure & Temperature dialog,
Place you cursor in the Pressure field and press F1 on the keyboard for complete details about this field.
Question: How does these programs deal with the thermal stratification in the piping system? Provide the details on modeling?
Answer: It doesn't, one would have to manually deal with this. ADINA might be able to handle it with their thermal and fluid flow capability
Loads and Load Sets - AutoPIPE
Bentley AutoPIPE