Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
AutoPIPE
  • Product Communities
AutoPIPE
AutoPIPE Wiki 02. Stress Isometric reported table values are not the highest value in the AutoPIPE model, why?
    • Sign In
    • -Pipe and Vessel Stress Analysis - Wiki
      • +ADL PIPE
      • -Bentley AutoPIPE
        • +- General Information about AutoPIPE
        • +- NEW User Guide for AutoPIPE
        • +- Technical Support - AutoPIPE
        • +Batch Processing, ITS, and ATS using AutoPIPE
        • AutoPIPE QA&R program
        • +Download - Install - Release Notes - AutoPIPE
        • +File / Model Management using AutoPIPE
        • +General - AutoPIPE
        • +Graphics - AutoPIPE
        • +Grids (Input & Results) - AutoPIPE
        • +Import and Export - AutoPIPE
        • +Known Issues in AutoPIPE (Enhancements, defects, etc..)
        • +Libraries - AutoPIPE
        • +License AutoPIPE -
        • +Loads and Load Sets - AutoPIPE
        • +Localization (Non-English Language) - AutoPIPE
        • +Modeling Approaches in AutoPIPE
        • +Modules (i.e. Flange Analysis, Spring Hanger Selection, Rotating Equip, TTA) in AutoPIPE
        • +Piping codes - AutoPIPE
        • +Post Processing - AutoPIPE
        • +Printing - AutoPIPE
        • +Reports - AutoPIPE
        • Security
        • +Settings - AutoPIPE
        • -Stress Isometrics - AutoPIPE
          • - How do I create a Stress Iso in AutoPIPE using OPIM?
          • -.OPIM Stress Isometric Troubleshooting Guide using AutoPIPE V8i 09.06.01.xx and higher
            • +00. Introduction to StressISO to OpenPlant Isometrics Manager
            • 00e. AutoPIPE Stress Isometrics Export Limitations from OPIM
            • -01. AutoPIPE Stress Isometric Troubleshooting: Table Issues
              • 01. Stress Isometric table shows a different piping code than in the printed header, why?
              • 02. Stress Isometric reported table values are not the highest value in the AutoPIPE model, why?
              • 03. How to Modify Stress Isometric Table length as not to exceed the border area when using OPIM in AutoPIPE?
              • 04. Stress Isometric: spring hanger Hot load (Hanger Hot), TDisp (Thermal Movement), & Var. % report zero in OPIM's summary data table generated by AutoPIPE, why
            • +02. Customize AutoPIPE Stress Isometric drawings
            • +03. AutoPIPE Stress Isometric Troubleshooting: Dimension Issues
            • 04. AutoPIPE Stress Isometric Troubleshooting: Dimension Issues
            • +05: Reasons why OPIM stress Isometric does not create a drawing file or drawing is blank from an AutoPIPE model?
            • 06. How to install OPIM (OpenPLANT Isometric Manager) without internet access?
            • 07. Why are Stress Isometric Break Points not saved in an AutoPIPE model?
            • 08. How to associate a program opening DGN or DWG file created by AutoPIPE?
            • 09. How to modify drawing border used to export a Stress Isometric in AutoPIPE 9.6 and Higher?
            • +10. Stress Isometric Settings in AutoPIPE
          • .Stress Isometrics features in AutoPIPE V8i 09.06.02.xx and higher
          • Alias StressISO for AutoPIPE 09.06.01.xx and Lower - Stress Iso Configuration files
          • +Alias StressISO for AutoPIPE 09.06.01.xx and Lower - Stress Iso Export: There were some warnings and/or errors while executing ISOGEN
          • Alias StressISO for AutoPIPE 09.06.01.xx and Lower - Beam / Pipe trunnions are not displayed in StressISO
          • Alias StressISO for AutoPIPE V8i 09.06.01.xx and Lower
          • Alias StressISO Troubleshooting Tips for AutoPIPE 09.06.01.xx and Lower
          • Q0. What are the difference between a Stress Isometric and Fabrication Isometric using AutoPIPE?
          • Q1. What was the last version of AutoPIPE that supported Alias StressISO Isogen application?
          • Q2. Can you combine an older version with Isogen and new version of with OPIM in AutoPIPE?
          • Q3. Is the extra StressISO Add-on license required in order to create a Stress Isometric using AutoPIPE 09.06.02.06 or higher with the OpenPlant Isometrics manager?
          • Q4. Is it necessary to install OPIM prior to using AutoPIPE Stress Isometric feature?
          • Q5. Is Bentley going to have any conversion procedure for AutoPIPE Stress-Iso to OpenPlant Isometrics Manager (OPIM)?
          • Q6. Can a Stress Isometric be created without an additional OPIM license?
          • Q7. Can I open the AutoPIPE Isometric file from Windows Explorer without incurring over usage charges?
        • +Technology Productivity Capabilities
        • +Warnings, Errors, Crashed, Confirm, etc.. messages in AutoPIPE
      • +Bentley AutoPIPE Nozzle (WinNOZL)
      • +Bentley AutoPIPE Vessel (powered by Microprotol)
      • +Bentley PlantFLOW
      • +Bentley PULS
    • Multi-lingual announcement from BENTLEY TECHNICAL SUPPORT.
    • Working at Home with AutoPIPE
    • +AutoPIPE Brand Learning Resources
    • +Attend a live meeting with an AutoPIPE Analyst

     
     Questions about this article, topic, or product? Click here. 

    02. Stress Isometric reported table values are not the highest value in the AutoPIPE model, why?

    Applies To
    Product(s): AutoPIPE
    Version(s): 2004, XM, V8i, CONNECT;
    Area: ISOmetric
    Original Author: Bentley Technical Support Group
    Date Logged
    & Current Version
    Nov. 2015
    10.00.00.10

    Problem:

    Stress Isometric reported table values are not the highest value in the AutoPIPE model, why? 

    Example:

    When i tick the Stress summary in Table option it results with just code check for one point in segment. In addition it seems that the program plots the envelope of code stress but prepared in wrong way, instead how highest stresses it plots lowest stresses in range.

    Solution:

    The problem maybe related to local settings on the computer. In some countries (ex. Poland) comma are used to separate the numbers from decimal fractures. Reset back to decimals and the reported table values are correct. 

    See Also

    _OPIM Stress Isometric Troubleshooting Guide using AutoPIPE V8i 09.06.01.xx and higher

    Bentley AutoPIPE

    OpenPlant Isometrics Manager

    • AutoPIPE
    • stress
    • isometric
    • table
    • Share
    • History
    • More
    • Cancel
    • Mike Dattilio Created by Bentley Colleague Mike Dattilio
    • When: Wed, Dec 2 2015 12:13 PM
    • Mike Dattilio Last revision by Bentley Colleague Mike Dattilio
    • When: Tue, Sep 4 2018 8:27 AM
    • Revisions: 5
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies