The following message appears when trying to analyze a model in AutoPIPE, why?
Forrtl: severe (104): incorrect POSITION= specifier value connected
file, unit 101, file
Image PC Routine, Line Source
Libifcoremd.dll 0D7091AA Unknown
Stack trace terminated abnormally
To date there has only been one reported occurrence that caused the above to appear. Confirm the following to be correct:
1. Check Modal analysis
Make sure that there is more that 1 mode of vibration, suggest using "Analyze up to Cutoff Frequency" option (by default = 33 hz).
2. Confirm Time History analysis
If performing a fluid transient, do not enable "Ground motion" option. Instead display the Time History Analysis - Ground Motion dialog
3. Close program and delete the all folders starting that start with AP_ from the following location:
C:\Users\***username***\AppData\Local\Temp\AP_***
4. Confirm user has read / write privileges to the folder above.
Visual Fortran run-time error messages
Bentley AutoPIPE
Bentley Technical Support KnowledgeBase
Bentley LEARN Server