Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
AutoPIPE
  • Product Communities
AutoPIPE
AutoPIPE Wiki 10. Why is there a difference in results between the Normal Sustain load (ex. Gr+MaxP (1)) and the Hydrotest Sustain load (ex. Gr+MaxP (2)) in AutoPIPE?
    • Sign In
    • -Pipe and Vessel Stress Analysis - Wiki
      • +ADL PIPE
      • -Bentley AutoPIPE
        • +- General Information about AutoPIPE
        • +- NEW User Guide for AutoPIPE
        • +- Technical Support - AutoPIPE
        • +Batch Processing, ITS, and ATS using AutoPIPE
        • AutoPIPE QA&R program
        • +Download - Install - Release Notes - AutoPIPE
        • +File / Model Management using AutoPIPE
        • +General - AutoPIPE
        • +Graphics - AutoPIPE
        • +Grids (Input & Results) - AutoPIPE
        • +Import and Export - AutoPIPE
        • +Known Issues in AutoPIPE (Enhancements, defects, etc..)
        • +Libraries - AutoPIPE
        • +License AutoPIPE -
        • -Loads and Load Sets - AutoPIPE
          • 01. Animate Load cases - AutoPIPE
          • 02a. Load Case Descriptions in AutoPIPE
          • +02b. Static Analysis in AutoPIPE
          • +02c. Dynamic Analysis in AutoPIPE
          • -02e. "Hydrotest" - AutoPIPE Load Case
            • 01. Why are my V-stops not allowing lateral movement during a Hydrotest load case in AutoPIPE ?
            • 02. Is there a method to perform a Hydrotest as a non-linear analysis in AutoPIPE?
            • 03. Where are the factors and values that are used in a Hydrotest load case located in AutoPIPE's output (report) file
            • 04. Why are my Hydrotest results so high in AutoPIPE?
            • 05. How to apply the Hydrotest load and analyze it in the new version of AutoPIPE V8i 09.06.01.10?
            • 06. Why does the Hydrotest case show an Allowable K Factor of 0.9 in AutoPIPE?
            • 07. How to assign code allowable stress for hydrotest loading: hoop stress and HY stress combination in AutoPIPE?
            • 08. How to calculate the Hydrotest Hoop stress and Allowable values in AutoPIPE?
            • 10. Why is there a difference in results between the Normal Sustain load (ex. Gr+MaxP (1)) and the Hydrotest Sustain load (ex. Gr+MaxP (2)) in AutoPIPE?
            • 11. How to apply more than one hydro-test analysis sets with different settings to an AutoPIPE model?
            • 14. Why is the gravity load case results weigh more than the Hydrotest gravity load case results on a Gas pipe line modeled in AutoPIPE?
          • +02f. "Static Earthquake" - AutoPIPE Load Case
          • +02g. "Wind" - AutoPIPE Load Case
          • +02h. "Snow Load" - AutoPIPE Load Case
          • 02i. "Thermal Bowing" - AutoPIPE Load Case
          • +02k. "Response / Force Spectrum Loads" - AutoPIPE Load Case
          • +02n. "Harmonic" - AutoPIPE Load case
          • 02p. "Time History" (M1-M50) - AutoPIPE Load Case
          • 02s. "Buoyancy" - AutoPIPE Load Case
          • +02t. "Wave" - AutoPIPE Load Case
          • +02u. "Fluid Transient" - AutoPIPE Load Case
          • 02v. "Steam Relief" - AutoPIPE Load Case
          • +02w. "Thermal Transient Analysis" (TTA) - AutoPIPE Load Case
          • +03a. "Gravity" - AutoPIPE Load Case
          • +03b. "Pressure" - AutoPIPE load case
          • 03c. "Temperature" - AutoPIPE load case
          • +03d. "SAM" (Seismic Anchor Analysis) - AutoPIPE load case
          • +03e. "Fatigue" - AutoPIPE load case
          • +03f. "Xtra Data" - AutoPIPE load case
          • +03g. "Occasional" - AutoPIPE load case
          • 03h. "Distributed Load" - AutoPIPE load case
          • 04. Results From Loads and Load Sets Not Answered By Piping Code Calculations
          • +05. Combination Load Cases (Tools> Combinations dialog)
          • +06. Non-linear Load Sequencing Explained
        • +Localization (Non-English Language) - AutoPIPE
        • +Modeling Approaches in AutoPIPE
        • +Modules (i.e. Flange Analysis, Spring Hanger Selection, Rotating Equip, TTA) in AutoPIPE
        • +Piping codes - AutoPIPE
        • +Post Processing - AutoPIPE
        • +Printing - AutoPIPE
        • +Reports - AutoPIPE
        • Security
        • +Settings - AutoPIPE
        • +Stress Isometrics - AutoPIPE
        • +Technology Productivity Capabilities
        • +Warnings, Errors, Crashed, Confirm, etc.. messages in AutoPIPE
      • +Bentley AutoPIPE Nozzle (WinNOZL)
      • +Bentley AutoPIPE Vessel (powered by Microprotol)
      • +Bentley PlantFLOW
      • +Bentley PULS
    • Multi-lingual announcement from BENTLEY TECHNICAL SUPPORT.
    • Working at Home with AutoPIPE
    • +AutoPIPE Brand Learning Resources
    • +Attend a live meeting with an AutoPIPE Analyst

     
     Questions about this article, topic, or product? Click here. 

    10. Why is there a difference in results between the Normal Sustain load (ex. Gr+MaxP (1)) and the Hydrotest Sustain load (ex. Gr+MaxP (2)) in AutoPIPE?

    Applies To
    Product(s): AutoPIPE
    Version(s): 2004, XM, V8i, CONNECT;
    Area: Results
    Original Author: Bentley Technical Support Group
    Date Logged
    & Current Version
    Dec. 2015
    10.00.00.10

    Problem:

    Why is there a difference in results between the Normal Sustain load (ex. Gr+MaxP (1)) and the Hydrotest Sustain load (ex. Gr+MaxP (2)) in AutoPIPE? 

    Another words, when I review the results, see that Gr+MaxP (1) and Gr+MaxP (2) are significantly  different:

    Why?

    Solution:

    In order to answer what is the driving reason behind the difference, break out each load case that makes up these combinations into individual load case combinations

    1. First review the Analysis Summary to understand the Combinations:

    Notice that the only difference between these 2 combinations is Gr(1) and Gr(2).

    2. Create new Code combinations Gr1 and Gr2

    3. Run analysis and review results for GR(1) and Gr(2) only:

    4. Clearly the results are different between these 2 load cases. Question is Why? 

    Next review the Static Analysis Set settings under Load> Static Analysis Sets.. command

    5.  The Analysis Sets Settings Appear to be exactly the same. 

    Next Review the Hydrotest settings and Pipe Property settings.

    6. See the Hydrotest Settings:

    7.  See the Pipe Property Settings:

    The problem has been solved. What you missed the answer. Please see the Hydrotest and Pipe Property dialogs above and ask what would cause a difference in Gravity load?

    Answer:

    Elementary, the Specific gravity of contents. In the Hydrotest it was set to 1.00 while in the pipe properties it is set to 0.00. Hence the reason for the different values in Gravity.

    Set both values to be the same, re-run the analysis, and review the results:

    Note: check to be sure that "Include insulation and cladding" has been enabled/ disabled to correctly account for weight during comparison. 

    A new enhancement has been logged 568905 - Update hydrotest code combination reporting for non-hydrotest load combinations to avoid these issues. 

    See Also

    "Hydrotest" - AutoPIPE Load Case

    Bentley AutoPIPE

    • Load Case
    • AutoPIPE
    • gravity
    • Hydrotest
    • Share
    • History
    • More
    • Cancel
    • Mike Dattilio Created by Bentley Colleague Mike Dattilio
    • When: Fri, Dec 18 2015 4:18 AM
    • Mike Dattilio Last revision by Bentley Colleague Mike Dattilio
    • When: Mon, Jun 4 2018 1:59 PM
    • Revisions: 4
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal