Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
AutoPIPE
  • Product Communities
AutoPIPE
AutoPIPE Wiki G. Crashed when AutoPIPE command, Tool> Model Consistency Check, was used
    • Sign In
    • -Pipe and Vessel Stress Analysis - Wiki
      • +ADL PIPE
      • -Bentley AutoPIPE
        • +- General Information about AutoPIPE
        • +- NEW User Guide for AutoPIPE
        • +- Technical Support - AutoPIPE
        • +Batch Processing, ITS, and ATS using AutoPIPE
        • AutoPIPE QA&R program
        • +Download - Install - Release Notes - AutoPIPE
        • +File / Model Management using AutoPIPE
        • +General - AutoPIPE
        • +Graphics - AutoPIPE
        • +Grids (Input & Results) - AutoPIPE
        • +Import and Export - AutoPIPE
        • +Known Issues in AutoPIPE (Enhancements, defects, etc..)
        • +Libraries - AutoPIPE
        • +License AutoPIPE -
        • +Loads and Load Sets - AutoPIPE
        • +Localization (Non-English Language) - AutoPIPE
        • +Modeling Approaches in AutoPIPE
        • +Modules (i.e. Flange Analysis, Spring Hanger Selection, Rotating Equip, TTA) in AutoPIPE
        • +Piping codes - AutoPIPE
        • +Post Processing - AutoPIPE
        • +Printing - AutoPIPE
        • +Reports - AutoPIPE
        • Security
        • +Settings - AutoPIPE
        • +Stress Isometrics - AutoPIPE
        • +Technology Productivity Capabilities
        • -Warnings, Errors, Crashed, Confirm, etc.. messages in AutoPIPE
          • "1 Interrupted Action" messages displayed while coping AutoPIPE file, why?
          • +"Alert" Messages displayed in AutoPIPE
          • +"AutoPIPE Licensing" Messages displayed in AutoPIPE
          • +"Autopipe.exe" Messages displayed in AutoPIPE
          • +"Beam Section" Messages displayed in AutoPIPE
          • +"Bentley AutoPIPE" Messages displayed in AutoPIPE
          • +"Bentley Systems, Inc" Messages displayed in AutoPIPE
          • "Bentley.lictransmit for Windows has stopped working" message appears when using AutoPIPE program, why?
          • +"Blank" Messages displayed in AutoPIPE
          • +"Bolts*" Messages displayed in AutoPIPE
          • +"Confirm" Messages displayed in AutoPIPE
          • +"Error" messages displayed in AutoPIPE
          • +"Flange*" Messages displayed in AutoPIPE
          • +"Incorrect Data" messages displayed in AutoPIPE
          • +"Intel(r) Visual Fortran run-time error" messages displayed in AutoPIPE
          • +"Invalid Format" messages displayed in AutoPIPE
          • +"License Management Tool" Messages displayed in AutoPIPE
          • "Message from SofTrack" Messages displayed in AutoPIPE
          • +"Microsoft .NET Framework".. messages displayed in AutoPIPE
          • "Microsoft Visual C++ Runtime Library" message appears in AutoPIPE
          • "New Case Failed" Messages displayed in AutoPIPE
          • +"Note" Messages in AutoPIPE
          • +"PCFin" Messages displayed in AutoPIPE
          • +"Report Generator Error" Messages displayed in AutoPIPE
          • +"Reverse Segment" Messages displayed in AutoPIPE
          • +"SACS Export Error" messages displayed in AutoPIPE
          • +"Script Error" messages displayed in AutoPIPE
          • +"Text Node Editor" Messages displayed in when using OPIM from within AutoPIPE
          • "Unable to Import the Excel File..." Messages displayed in AutoPIPE
          • +"Warnings" Messages displayed in AutoPIPE
          • 01. "C:\Program Files (X86)\..." - Type mismatch dialog message appears when reviewing the results grids in AutoPIPE, why?
          • -Application Crashed or Freezes - AutoPIPE
            • - Is this an valid AutoPIPE model?
            • +01. Bentley AutoPIPE Application has stopped working - "A problem caused the....
            • +02. Bentley AutoPIPE has crashed
            • 03. Bentley AutoPIPE Application has stopped working: "A problem caused the program to stop working correctly. Please close the program"
            • 04. Program periodically freezes, toolbars disappear, and application crashes - AutoPIPE V8i 09.05.01.02
            • 05. Bentley AutoPIPE is (NOT RESPONDING) or "Bentley AutoPIPE Application is not responding" message appears
            • 06. The application has failed to start becuase of IEGLic.dll was not found
            • 07. Microsoft Blue Screen - A problem has been detected and Windows has been shut down to prevent damage to your computer
            • 08. AutoPIPE crashes or nothing appears on startup (i.e. no splash screen), Faulting module name: ntdll.dll
            • 09. AutoPIPE Report Viewer has stopped working
            • 10. AutoPIPE crashes, Faulting application name: Bentley.Licensing.Service.exe, appears in event viewer, why?
            • +A. Crashed when opening an AutoPIPE model, what can be done?
            • +B. Crashed when Importing / Inserting into an AutoPIPE model, what can be done?
            • +C. AutoPIPE Crashes / Freezes on Start-up
            • E. Crashed when AutoPIPE command to Analyze> All was initiated
            • F. Crashed when AutoPIPE command to File> Save Stress Isometric
            • G. Crashed when AutoPIPE command, Tool> Model Consistency Check, was used
            • +I. Crashed when performing: Results> Output Report in AutoPIPE
            • J. Why does AutoPIPE crash while working on the Input/results grids?
            • K. Crashed when AutoPIPE command to view Load> Dynamic Analysis Dialog Screen was started
            • +L. AutoPIPE quits for no apparent reason or when not using any specific command, why?
            • M. AutoPIPE quits after using copy command, why?
            • +N. Issues related to AutoPIPE crashing when making modifications on piping component dialog
          • AutoPIPE Report Viewer has stopped working
          • +Blank Messages displayed in AutoPIPE
          • +Issues that occur when exporting files from AutoPIPE
          • +Issues that occur when generating Reports from AutoPIPE
          • +Issues that occur when importing PXF files into AutoPIPE
          • +Known errors that occur when Installing / Uninstalling AutoPIPE
      • +Bentley AutoPIPE Nozzle (WinNOZL)
      • +Bentley AutoPIPE Vessel (powered by Microprotol)
      • +Bentley PlantFLOW
      • +Bentley PULS
    • Multi-lingual announcement from BENTLEY TECHNICAL SUPPORT.
    • Working at Home with AutoPIPE
    • +AutoPIPE Brand Learning Resources
    • +Attend a live meeting with an AutoPIPE Analyst

     
     Questions about this article, topic, or product? Click here. 

    G. Crashed when AutoPIPE command, Tool> Model Consistency Check, was used

    Applies To
    Product(s): AutoPIPE
    Version(s): 2004, XM, V8i, CONNECT;
    Environment: N/A
    Area: Crashed
    Subarea:
    Original Author: Bentley Technical Support Group
    Date Logged
    & Current Version
    Dec. 2015
    10.00.00.10

    Problem:

    With a given model opened in AutoPIPE, after pressing Tools> Model Consistency Check the program crashes, why?

    Answer:

     There are a number of reasons why this issue may occur, below are know issues and fixes:

    Reason #1:

    The program hangs when performing consistency check on segment and does not return the control. A segment that contains only one point with invalid data can cause the crash. Search the model for all segments and remove any segments that has only node point.

    The CAE development team has been unable to repeat in creating a model with this issue, but knows how to fix the problem once it occurs. If anyone has any steps to repeat that causes this problem, please log a Bentley Service Request and send the details for review. 

    See Also

    Application Crashed or Freezes - AutoPIPE

    Bentley AutoPIPE

    External Links

    Bentley Technical Support KnowledgeBase

    Bentley LEARN Server

    Comments or Corrections?

    Bentley's Technical Support Group requests that you please submit any comments you have on this Wiki article to
    the "Comments" area below. THANK YOU!

    • AutoPIPE
    • Model Consistency Check
    • crashed
    • Share
    • History
    • More
    • Cancel
    • Mike Dattilio Created by Bentley Colleague Mike Dattilio
    • When: Tue, Dec 22 2015 6:19 PM
    • Mike Dattilio Last revision by Bentley Colleague Mike Dattilio
    • When: Tue, Dec 22 2015 6:21 PM
    • Revisions: 2
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies