The following warning appeared when performing a model consistency check:
W2143-45:A Yield(Sy) value of less than or equal to 1.00000 psi is detected on some points.
How to resolve and avoid it?
Somewhere in the model is a Sy value <= 1.00 psi. The easiest way to locate this node point(s), open the Input Grids and select the Pressure/Temp/Pipe Id tab, scroll over to the column for Sy, and double click the column heading to place the column in ascending order, double click the column header again to place the column in descending order. Once in order look for all node points that have a Sy <= 1.00 psi and make the necessary changes.
This same technique can be performed on the Pipe properties tab for the cold Sy value(s).
Warnings Messages displayed in AutoPIPE
Bentley AutoPIPE
Bentley Technical Support KnowledgeBase
Bentley LEARN Server
Bentley's Technical Support Group requests that you please submit any comments you have on this Wiki article tothe "Comments" area below. THANK YOU!