The following appeared while using AutoPIPE:
Coincident Node Check (Analysis > Model Validation > Coincident Node Check)
---------------------------Note--------------------------- N2154-12: Coincident node tolerance is zero, check disabled.---------------------------OK ---------------------------
Why?
Typically this note message will appear when trying to invoke the Tools> Coincident node Check command. See AutoPIPE help for details on this command:
Select this option to perform a coincident node check on the complete model based on the tolerance under Tools>Model options >Edit (Coincident Node Tolerance (0- no check))
Review the Node tolerance to be greater than 0.00 before using this command.
"Note" Messages in AutoPIPE
Bentley AutoPIPE