You are currently reviewing an older revision of this page.
Program crash while generating code compliance report for "Seis+Ther" category combination
Program may crash for following Piping Codes while generating code compliance report for combination of "Seis+Ther" category
- B31.1 - 2004 and higher
- NC - 2004 and higher
- ND - 2004 and higher
This issue has been logged under TFS-D363068 and will be fixed in a future version of the program,
- Open WALKTHRU.DAT model.
- Export to NTL file. Notice that there is no BPOP card (Buried Pipe Options data).
- Import NTL file.
- Change piping code to B31.1 code.
- Analyze model.
- Open Combination dialog and create new combination with “Combination Method = Sum” and “Category = Seis+Ther
- Generate “Code Compliance” report.
Open Buried Pipe Result Options dialog and click OK to recreate the combination. Again, generate a complete output report.
This issue has been fixed in AutoPIPE CONNECT 10.01.00.04 and higher.