You are currently reviewing an older revision of this page.
How to hide label "NS" from being displayed on an AutoPIPE Stress Isometric using OPIM?
Close AutoPIPE
Using AutoPIPE CONNECT 10.00.00.10 or higher:
The style.xml file requires an update. It is located in following folder:
“C:\ProgramData\Bentley\AutoPIPE CONNECT\isoextractor\projects\project01\stress\Config”
The file can be opend in any Text editing application (i.e. MS Word, NotePAD, UltraEdit ect..)
After the file is opened, search for the following entry <PipeDiameter>%NS</PipeDiameter>
must be changed to <PipeDiameter>% </PipeDiameter>.
Save the file, close the file, start AutoPIPE, open/create a model, save a Stress Isometric and confirm the setting works.
Customize AutoPIPE Stress Isometric drawings
Bentley AutoPIPE
Bentley Technical Support KnowledgeBase
Bentley LEARN Server
Bentley's Technical Support Group requests that you please submit any comments you have on this Wiki article tothe "Comments" area below. THANK YOU!