04o. How to model a Smart Pig going thru the Pipeline in AutoPIPE?


Applies To
Product(s):AutoPIPE
Version(s):2004, XM, V8i, CONNECT;
Area: Modeling
Original Author:Bentley Technical Support Group
Date Logged
& Current Version
Apr. 2016
10.01.00.05

Problem:

I am trying to apply moving load representing a smart inspection pig moving through the pipe as some speed on top of operating pressure. And I also want to add this moving load to a load combination. How to model in AutoPIPE?

Solution:

Fluid transient isn't any use for a pig only FTH (Force Time History). Model this as a single slug flow wave and add Slug flow load case to your combinations.

Bentley has a training for Slug Flow that people could attend. Suggest checking the Learn Server for when the next training class will become available. 

See Also

Modeling Approaches in AutoPIPE

Bentley AutoPIPE