How can I input allowable loads for my nozzles to AutoPIPE and get a report about pump check results?
Rotating Equipment utility does not permit the user to enter user defined allowables. The allowables calculated in this report are per code requirements and are described in the online help:
Help > Contents> Contents Tab> Reference Information> Rotating Equipment Calculations>
One suggestions to enter in a user allowable values where it can clearly reported as Pass / Fail is to use Insert > Xtra Data> Reference Point> see online help fro details on this command.
This feature permits the user to compare the calculated loads against a set of user defined allowables and to clearly see the results in the Output Report's Reference Point sub-section. Furthermore, using the "Report Reference Point Results to AutoPIPE Nozzle" option, the user can send the loads over to AutoPIPE Nozzle for further analysis (free for AutoPIPE Advanced and Nuclear licenses).
Rotating Equipment
Bentley AutoPIPE
Bentley Technical Support KnowledgeBase
Bentley LEARN Server