You are currently reviewing an older revision of this page.
How to add coordinate information to a support node point on a Stress Isometric using OPIM?
This setting was controlled by Alias Isogen command switch 66, however this feature can replicated using OPIM (see the following instructions):
1. Open the following file in any text editor:
C:\ ProgramData \ Bentley \ AutoPIPE CONNECT \ isoextractor \ projects \ project01 \ stress \ Config \ style.xml
2. After the file opens, locate the <userLabels> section. Typically found on line #4 of a default file.
3. Add the following out side of another entry command statement between the <userlabels> (line #4) and </userlabels> (line #198).
<entry>
<name>Support coordinates</name>
<id>536456ff-1db2-434f-a8c0-21c163829c24</id>
<include>IE_TYPE=CT_SUPPORT</include>
<exclude>
</exclude>
<text>$(COORD)</text>
<type>NOTE</type>
<cellName>NOTE</cellName>
<flags>
</flags>
<PlaceLabel>True</PlaceLabel>
</entry>
4. Save and close the file
5. Restart AutoPIPE
6. Create a Stress Isometric using OPIM. coordinate location is now displayed at a support location:
Bentley AutoPIPE
Bentley Technical Support KnowledgeBase
Bentley's Technical Support Group requests that you please submit any comments you have on this Wiki article intoa Bentley SR for review and reply. THANK YOU!