1087906
ASME NC/ND: Allowable case for Sh, Sy in Eq. 9 is incorrectly used for 1980+1980S add. and earlier editions
1035676
ASME NB: Equation 11 Temperature distribution terms for tee points always use the second tee
header leg material properties which may not be conservative for Tees with varying material across
the legs
1010996
Insert new valve dialog may load incorrect length, surface area factor and weight from previously inserted valve
960482
ASME Material Library: SA182-F22 values are incorrectly updated for ASME2000 and later material libraries
958453
ASME Material Library : Thermal expansion, Modulus of elasticity and Design stress intensity values for some pipe materials may not be correct
798781
ASME NC/ND: Equation 11 allowable calculation is incorrectly impacted by selected equation 9 allowable case
702173
ASME Nuclear: Incorrect density, composition, and modulus values for standard pipe materials NI and GROUP-1-B
702082
ASME NC/ND: Stress Summary calculations incorrectly uses branch pressure and geometry for pressure term calculations
673865
ASME NB: Stress, allowable and SIF calculations for a reducer may use incorrect Pipe properties and Pressure/Temperature data
620771
ASME NB: Thermal ratchet allowable may be calculated incorrectly when the ratio of pressure stress over yield strength is greater than or equal to 1
619540
ASME NB: Incorrect stress results may be reported for negative face of a reducer node that is directly connected to a tee branch
537789
ASME NB: Stress summary containing equation 10 transient with a user defined non-reversing SAM category combination may give incorrect results
407514
Material properties set for valve or flexible joint are used to calculate allowable stress for pipe that follows
372995
ASME NB thermal transient analysis gross discontinuity stress may be incorrectly calculated at locations involving last TTA pipe
354776
ASME NB: Tee moments may use incorrect sign and may lead to incorrect stress results when combining signed and unsigned combinations
331101
ASME NC/ND: C2r and C2b stress Indices may be incorrectly calculated for fillet welded and partial penetration welded branch connections
323304
ASME NC/ND: SIF value lower than 2.0 may be calculated when "Use SIF of 2.0" is checked
265109
JSME Class 2-PPC: B1 stress index is incorrectly reported as 1.0 for a reducer with cone angle value of 30.0
263384
Stress indices of bend are incorrectly applied to reducer
242019
JSME Class 2-PPC: B1 stress index is incorrectly reported as 0.5 for a reducer with cone angle value of 60.0
224470
JSME Class 2-PPC: Maximum applicable B1 and B2 indices value at a point may not be used
224452
JSME Class 2-PPC: B1 and B2 indices reported at valve far point are incorrect for valves that are not butt welded
181952
Tees with different material across tee legs may report inconsistent allowable values
179635
ASME NC/ND: Elbows with any flange type reports B1 factor for socket welding flange
177864
For ASME NC/ND, Reducers at Cone Angle 30 deg Reporting Wrong B1 Index
138755
SAM axial stress of plus face of a point uses axial force of minus face
138656
The allowable (K) factor does not reset after changing the stress category
138342
Ke is less than 1 when service level Rupture is selected and 2.4 Sm < Sn < 3 Sm
138250
BTP 1987 Rupture limit for equation 9 is using min. hot Sy instead of design Sy
138165
Minimum allowable is not used for tee stresses in JSME
137674
Pressure stiffening is not applied correctly when analysis sets are not analyzed
137580
User allowable stress is not used for Rest categories for B31.8
137570
Sustained stress allowable ignores creep if one T < Tcrp is included in analysis
137541
Pressure stiffening not applied to code stress for offshore codes and B31.8
137157
Reinforced tee B2r < 1.575 and C2r < 2.1 are incorrect for NC/ND 2003 and later
137139
User B1 and C3 stress indices limits are incorrect
137138
Zero stresses in the stress summary when number of loadsets exceeds 150
137130
Hoop stress in user combination is shown as zero if load case has Pressure 1
137118
ASME NB, NC and ND combined stress may be non-conservative for skewed pipe
137113
Tee header SIF is incorrectly used for branch in Japanese JSME 2005 code
137084
Maximum DT1 and DT2 stress is not used for tee in pre-verification report
137083
Pulled bend flexibility factor is conservatively set to 1.0
137074
SAM as Reverse dynamic gives zero SAM stresses in NB rev.dyn summary
137071
NC/ND 2004 tee stress for reverse dynamic stress summary is conservative
137069
B2 is used instead of B2' for girth BW with thickness change for Rev Dyn Summary
137040
Abutting bend stress indices are too conservative for pipe thickness < 3/16"
137009
Abutting elbow C2 index is using NB 1992 girth weld C2 formula for earlier years
137008
Problem with entering OTHER tee for JSME code
137006
Branch Type Tee SIFs and stress indices for JSME code are using NC 2004 values
137003
Eqn.8 & 9 stress summary may be incorrect at plus side of tee for NC/ND 2004
137002
ASME NB/NC/ND OTHER tee stress indices maybe incorrect
135993
Changing pipe material in the input grid does not update thermal expansion alpha
135841
ASME B31.3 App P option causes different results in multiple load sets
135837
SAM Axial stress results are zero for ASME ND code 94 or later
135812
Some pipe properties for plus point is used for minus point for ASME NB, NC&ND
135796
ASME NB Equation 9 Allowable may change based on last load set pair
135767
Pressure stiffening correction is not applied to SIF factor
135731
Tee data switched when rigid options are inserted on a branch
135723
Negative force/disp/gross disc. or cut short may cause incorrect stresses
135713
Ratchet stress is incorrect for SI units
135707
C2 for ASME NC/ND 1994 and later ignores longitudinal weld
135704
Hanger Selection: HGR file is not created in Analyze / All
135698
ASME NB Thermal Ratchet shows Delta-T1 range from last load set pair
135693
ASME NB 1989 socket weld indices for Cx<=0.75tn are always used for later years
135690
B2' = 1.5 is always used for Socket welds for NC/ND 2001 and later
135647
Equation 11a should not be used for years before 1994 in pre-verification report
135642
Girth Butt weld SIF maybe > 1.0 for t < 0.237" and ASME NC/ND 2001 and later
135638
Moment summation incorrectly applied to reverse dynamic loads for NC 1972-1980
135637
Problem with tee run moment summation for unsigned SAM cases
135501
For ASME NB-1975 add, K2 and K3 indices are incorrect for Flush BW Transition
135482
TTA Pipe and Insulation grid blocks valid pipe thickness input for SI Units
135367
Stress level code combinations like (SUS) are ignored for ASME NB/NC/ND
135356
Reinforced tee B2b & B2r stress indices are set equal for NC/ND 2003-2004 code
135355
Code year NC/ND 1980 Summer is mislabeled as 1982a. Also ND 1983W is mislabeled
135309
Program incorrectly shows code check failing when equation 10 fails for ASME NB
135306
Moment summation at the tee for ASME NB ignores moment sign for second leg
135289
ASME NB 1977 K2 and K3 stress indices are incorrect for some welded transitions
135271
For vertical API610 pumps, stresses are NaN when AUTODIN is used
135248
New KHK2 models show zero results except for combinations with PW
135242
DeltaT1 and DeltaT2 units are not converted correctly when switching to SI units
135239
New KHK2 models show default combinations as those of KHK1 piping code
135238
Stress at pipe end of far reducer point with a support has zero moment
135204
Pipe side SIF at far point of reducer may not be correct
135203
Butt Weld offset or mismatch is incorrectly used as offset ratio delta/t in SIF
135187
For ASME NC/ND 1986-1989 Girth Butt Weld SIF is set to 2.8 for t < 0.237 inches
135110
Pressure & allowable stresses can be incorrect for multiple analysis sets
135109
JSME: Cannot add load cases to combination in CS1(P+S) category
134441
Sustained stress adds up all P cases when multiple analysis sets are defined
134440
TTA profiles with long transients may return incorrect Delta T1 & T2 values
134435
Cannot enter a User B1 value of less than 0.5 for ASME NB
134434
Selecting load case in the Impose Disp. dialog always displays E49-40 for KHK
134426
Member static earthquake factor is not applied correctly at valve midpoint
134412
FY allowable force resets to 'none' for all reference point data
134411
Comb based on last analysis set only are correct in General Stress report
134326
Incorrect NC/ND reversing loads in Service Levels C & D for rotated tees
134325
Incorrect JSME moment summation for rotated tees
134323
Support dlg: Switch 'Constant' support (designed) to 'Spring' crashes program
134322
Valve with midpoint is exported incorrectly as a valve and run pipe to STAAD
134208
Incorrect ASME NB moment summation for rotated tees
129663
Stress indices and B2 correction factor for reducers may be calculated incorrectly
123586
Stress indices and moment of inertia may be calculated incorrectly for nodes with transition welds
See Also
Critical and High issues
Bentley AutoPIPE
critical
AutoPIPE
Known Issues
High
defect
09.01
First Affected Version
Share
History
More
Cancel
Created by
Mike Dattilio
When:
Thu, Sep 15 2016 10:22 AM
Last revision by
Mike Dattilio
When:
Tue, Jul 14 2020 12:37 PM
Revisions: