Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
AutoPIPE
  • Product Communities
AutoPIPE
AutoPIPE Wiki 04. How to change number of iterations for non-linear static analysis?
    • Sign In
    • -Pipe and Vessel Stress Analysis - Wiki
      • +ADL PIPE
      • -Bentley AutoPIPE
        • +- General Information about AutoPIPE
        • +- NEW User Guide for AutoPIPE
        • +- Technical Support - AutoPIPE
        • +Batch Processing, ITS, and ATS using AutoPIPE
        • AutoPIPE QA&R program
        • +Download - Install - Release Notes - AutoPIPE
        • +File / Model Management using AutoPIPE
        • +General - AutoPIPE
        • +Graphics - AutoPIPE
        • +Grids (Input & Results) - AutoPIPE
        • +Import and Export - AutoPIPE
        • +Known Issues in AutoPIPE (Enhancements, defects, etc..)
        • +Libraries - AutoPIPE
        • +License AutoPIPE -
        • +Loads and Load Sets - AutoPIPE
        • +Localization (Non-English Language) - AutoPIPE
        • +Modeling Approaches in AutoPIPE
        • +Modules (i.e. Flange Analysis, Spring Hanger Selection, Rotating Equip, TTA) in AutoPIPE
        • +Piping codes - AutoPIPE
        • +Post Processing - AutoPIPE
        • +Printing - AutoPIPE
        • +Reports - AutoPIPE
        • Security
        • +Settings - AutoPIPE
        • +Stress Isometrics - AutoPIPE
        • +Technology Productivity Capabilities
        • -Warnings, Errors, Crashed, Confirm, etc.. messages in AutoPIPE
          • "1 Interrupted Action" messages displayed while coping AutoPIPE file, why?
          • +"Alert" Messages displayed in AutoPIPE
          • +"AutoPIPE Licensing" Messages displayed in AutoPIPE
          • +"Autopipe.exe" Messages displayed in AutoPIPE
          • +"Beam Section" Messages displayed in AutoPIPE
          • +"Bentley AutoPIPE" Messages displayed in AutoPIPE
          • +"Bentley Systems, Inc" Messages displayed in AutoPIPE
          • "Bentley.lictransmit for Windows has stopped working" message appears when using AutoPIPE program, why?
          • +"Blank" Messages displayed in AutoPIPE
          • +"Bolts*" Messages displayed in AutoPIPE
          • -"Confirm" Messages displayed in AutoPIPE
            • Q. Confirm - Renumber does not affect external files. Are you sure you want to continue?....message in AutoPIPE
            • Q. Confirm - This model may be affected by a previous program defect.... message in AutoPIPE
            • Q. Confirm - Code / Non-code combinations with unanalyzed load cases were found. in AutoPIPE reports, why?
            • Q. Confirm - Current model revision does not match analysis result(s) below....message in AutoPIPE
            • Q. Confirm - Import Process successful. Review Warning message... message appears when importing a file into AutoPIPE
            • Q. Confirm - No range has been selected. Do you want to export the complete model? message appears in AutoPIPE, why and how to avoid?
            • -Q. Confirm - The load case did not converge. Do you wish to continue iterating? ... message in AutoPIPE
              • +01. What to do when "load case did not converge" message appears in AutoPIPE?
              • 02. How to read a *.LOG file in AutoPIPE?
              • 03. Does AutoPIPE as a whole have the same type of converging issues as seen by other programs?
              • 04. How to change number of iterations for non-linear static analysis?
              • 06. How to solve a friction force problem found in a Log file for AutoPIPE?
            • Q. Confirm - The model you are about to open was last modified in a newer version of the product ....message in AutoPIPE
            • Q. Confirm - Unable to update model "name" data files on the disk. message appears in AutoPIPE
            • Q. Large coordinates >1.0E+6 are detected in the PCF file... message was displayed when importing a model in AutoPIPE, why?
          • +"Error" messages displayed in AutoPIPE
          • +"Flange*" Messages displayed in AutoPIPE
          • +"Incorrect Data" messages displayed in AutoPIPE
          • +"Intel(r) Visual Fortran run-time error" messages displayed in AutoPIPE
          • +"Invalid Format" messages displayed in AutoPIPE
          • +"License Management Tool" Messages displayed in AutoPIPE
          • "Message from SofTrack" Messages displayed in AutoPIPE
          • +"Microsoft .NET Framework".. messages displayed in AutoPIPE
          • "Microsoft Visual C++ Runtime Library" message appears in AutoPIPE
          • "New Case Failed" Messages displayed in AutoPIPE
          • +"Note" Messages in AutoPIPE
          • +"PCFin" Messages displayed in AutoPIPE
          • +"Report Generator Error" Messages displayed in AutoPIPE
          • +"Reverse Segment" Messages displayed in AutoPIPE
          • +"SACS Export Error" messages displayed in AutoPIPE
          • +"Script Error" messages displayed in AutoPIPE
          • +"Text Node Editor" Messages displayed in when using OPIM from within AutoPIPE
          • "Unable to Import the Excel File..." Messages displayed in AutoPIPE
          • +"Warnings" Messages displayed in AutoPIPE
          • 01. "C:\Program Files (X86)\..." - Type mismatch dialog message appears when reviewing the results grids in AutoPIPE, why?
          • +Application Crashed or Freezes - AutoPIPE
          • AutoPIPE Report Viewer has stopped working
          • +Blank Messages displayed in AutoPIPE
          • +Issues that occur when exporting files from AutoPIPE
          • +Issues that occur when generating Reports from AutoPIPE
          • +Issues that occur when importing PXF files into AutoPIPE
          • +Known errors that occur when Installing / Uninstalling AutoPIPE
      • +Bentley AutoPIPE Nozzle (WinNOZL)
      • +Bentley AutoPIPE Vessel (powered by Microprotol)
      • +Bentley PlantFLOW
      • +Bentley PULS
    • Multi-lingual announcement from BENTLEY TECHNICAL SUPPORT.
    • Working at Home with AutoPIPE
    • +AutoPIPE Brand Learning Resources
    • +Attend a live meeting with an AutoPIPE Analyst

     
     Questions about this article, topic, or product? Click here. 

    04. How to change number of iterations for non-linear static analysis?

    Applies To
    Product(s): AutoPIPE
    Version(s): ALL;
    Environment: N/A
    Area: Analysis
    Original Author: Bentley Technical Support Group
    Date Logged
    & Current Version
    Sept. 2016
    10.01.00.09

    Problem:

    When analyzing a model the following occurs:

    ---------------------------
    Confirm
    ---------------------------
    The load case did not converge. Do you wish to continue iterating?
    ---------------------------
    Yes   No   Cancel  
    ---------------------------

    The default number of iterations is 30, Can this value be increased?

    Solution:

    Convergence is an iterative process that requires multiple passes in order to reduce the errors associated with initial estimates to an acceptable level. After each iteration, the [U] matrix is investigated for any effect on the stiffness matrix [K]. If [K] is affected, a new stiffness matrix is formed and the analysis is repeated until a solution is obtained. Since each loading condition can affect the system differently, a separate [K] matrix may be required for each defined load case. The iterative solution stops when all convergence criterion have been met (bearing, friction, & soil force and displacement).

    Convergence problems may be alleviated by reducing the friction restraint stiffness. Lower friction stiffness will more-readily distribute friction loads throughout the system and speed or allow nonlinear convergence but this lower stiffness will also affect the accuracy of the results. Lower stiffness values permit more "non-sliding" movement, but given the indeterminate nature of the friction problem in general, this error may not be crucial.

    To change the number of iterations in AutoPIPE select Load> Static analysis sets> Modify an analysis set> Gaps/Friction/Soil option must be checked ON, press OK button, on the non-linear analysis dialog screen change iteration setting to different value.


    See Also

    The load case did not converge...

    Bentley AutoPIPE

    • Static Analysis
    • AutoPIPE
    • converge
    • Non-Linear
    • Analysis Set
    • Share
    • History
    • More
    • Cancel
    • Mike Dattilio Created by Bentley Colleague Mike Dattilio
    • When: Thu, Sep 22 2016 12:47 PM
    • Mike Dattilio Last revision by Bentley Colleague Mike Dattilio
    • When: Fri, Jul 12 2019 4:04 PM
    • Revisions: 5
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies