Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
AutoPIPE
  • Product Communities
AutoPIPE
AutoPIPE Wiki 13. How to map a Line Number from a PCF file into AutoPIPE?
    • Sign In
    • -Pipe and Vessel Stress Analysis - Wiki
      • +ADL PIPE
      • -Bentley AutoPIPE
        • +- General Information about AutoPIPE
        • +- NEW User Guide for AutoPIPE
        • +- Technical Support - AutoPIPE
        • +Batch Processing, ITS, and ATS using AutoPIPE
        • AutoPIPE QA&R program
        • +Download - Install - Release Notes - AutoPIPE
        • +File / Model Management using AutoPIPE
        • +General - AutoPIPE
        • +Graphics - AutoPIPE
        • +Grids (Input & Results) - AutoPIPE
        • -Import and Export - AutoPIPE
          • 01: What file formats can AutoPIPE Import/Export?
          • -02. Imported related issues in AutoPIPE
            • +02-01.a: Import AutoPIPE DAT model
            • +02-01.b: Issues with Importing *.NTL file into AutoPIPE
            • -02-02. AutoPIPE Translators
              • +ADLPipe Translator - AutoPIPE
              • -PCF Translator Issues for AutoPIPE
                • -01. PCF Translator FAQ & troubleshooting - AutoPIPE
                  • 0. How to install AutoPIPE's PCF translator?
                  • +01. PCF Import process aborted or crashed: what should I do?
                  • +02. PCF Translator Freezes / Not Responding / disappears from screen; now what should I do in AutoPIPE?
                  • 03. Import from Autodesk Inventor PCF files show flanges and valves as weightless “Zero Weight” components, why and how to avoid when using PCF translator in AutoPIPE?
                  • 04. "E880-1: Error in opening import batch file. File extension must be NTL" message appear when importing a PCF fiule in AutoPIPE, why and how to avoid?
                  • 05. No graphical elements found for the components after importing file into AutoPIPE
                  • 06. Branch piping is not connected to the main header pipe in converted AutoPIPE PCF file, why?
                  • 07. When importing a PCF file, all the pipe sizes are very large or small in AutoPIPE, why and how to resolve?
                  • 08. When I open the .NTL file in AutoPIPE, it truncates my pressure values, why and how to avoid?
                  • +09. Is my piping code, material, and component supported in AutoPIPE's PCF translator?
                  • 10. Imported PCF file containing branch connection O-let / olet (weldolet, elbolet, threadolet, etc..) are not connected correctly in AutoPIPE model, why and how to avoid?
                  • 11. When importing a PCf file into AutoPIPE, Status = "Incorrect Component Connection Tolerance Value", why and how to avoid?
                  • 12. When importing a PCF file, all the pipe wall thickness values are very large in AutoPIPE, why and how to resolve?
                  • 13. How to map a Line Number from a PCF file into AutoPIPE?
                  • 13. PCF Translator closes abruptly when importing a model into AutoPIPE, how to fix it?
                  • +14. Mapping examples from PCF translator to AutoPIPE?
                  • 15. Why are parts of my PCF translated file into AutoPIPE missing piping or components?
                  • 16. Why are all imported flanges from a PCF file rotated 90 deg when opened in an AutoPIPE model?
                  • 17. How to reset the PCF translator PCFin.MAP used inside of AutoPIPE?
                  • 18. Parts of my PCF translated file into AutoPIPE have piping that is not connected, why?
                  • 19. How to remove Cad Length from AutoPIPE Model?
                  • 20. Cannot select a specific item from drop down listing when importing a PCF file into AutoPIPE, why?
                  • 21. How to filter out small bore piping from being translated into an AutoPIPE model?
                  • 22. What units are used for and how is the Bend Radius calculated when importing a PCF file into AutoPIPE?
                  • 23. How are bend radius calculated when importing a PCF file into AutoPIPE?
                  • 24. PCF Imported Bends are shown as straight pipe in AutoPIPE, why/
                  • Q. How to create a PCF file for AutoPIPE?
                • 03. PCF Translator: Known Issues
                • +04. PCF Translator Version History
                • +05. Added details about AutoPIPE's PCF Translator "Tools > Settings"
                • Q. Documentation on AutoPIPE's PCF translator
              • +STRAIT Translator in AutoPIPE
            • +02-02.d Import ISM files into AutoPIPE
            • 02-03.a1: Example 1 - After import, how to fix piping that are not all connected?
            • 02-03.a2: Example 2 - After import, how to fix piping that are not all connected?
            • +02-03.b: Import MS Excel or AutoCAD DWG / DXF into AutoPIPE?
            • 02-03.c: AutoDesk REVIT into AutoPIPE
            • 02-03.e.i: PXF Import : CADAP.MAP Options
            • +02-03.e: Troubleshooting - Import AutoPlant / OpenPLANT PXF file into AutoPIPE
            • 02-03.f: Can AutoPIPE Import Bentley Microstation model information?
            • 02-03.f: Can AutoPIPE V8i Import / Export Bentley HAMMER loads?
            • +02-03.h: Import PlantSPACE model into AutoPIPE
            • 02-03.i: Import ProStructures into AutoPIPE
            • +02-03.j: Insert> Model From Bentley SACS using PipeLink or ISM
            • +02-03.k: Insert> Model From STAAD Using PipeLink
            • 02-03.l: CAD To AutoPIPE Integration
            • 02-03.m: Import CIMSteel Integration Standards (CIS/2) or STP file information into AutoPIPE
            • +02-03.n: Import / Export caesar (cii) or Areva PDMS (cii) with AutoPIPE
            • 02-03.o: Import CAE Pipe or Kpipe into AutoPIPE
            • 02-03.r: Import OpenBIM data exchange (IFC) information into AutoPIPE
            • 02-03.s: Import Pipe Net into AutoPIPE
            • 02-03.t: Import PDMS using I-Sketch, I-Run or Spoolgen into AutoPIPE
            • 02-03.u: Import PTC Creo into AutoPIPE
            • 02-03.v: Can AutoPIPE Import SAP 2000 model file?
            • 02-03.w: Import TRIMBLE PIPEDESIGNER 3D into AutoPIPE
            • 04-001: While importing or copy paste into AutoPIPE model, the node numbers are renaming automatically. How to import / copy geometry without changing the node numbers?
          • +03. Exported related issues in AutoPIPE
        • +Known Issues in AutoPIPE (Enhancements, defects, etc..)
        • +Libraries - AutoPIPE
        • +License AutoPIPE -
        • +Loads and Load Sets - AutoPIPE
        • +Localization (Non-English Language) - AutoPIPE
        • +Modeling Approaches in AutoPIPE
        • +Modules (i.e. Flange Analysis, Spring Hanger Selection, Rotating Equip, TTA) in AutoPIPE
        • +Piping codes - AutoPIPE
        • +Post Processing - AutoPIPE
        • +Printing - AutoPIPE
        • +Reports - AutoPIPE
        • Security
        • +Settings - AutoPIPE
        • +Stress Isometrics - AutoPIPE
        • +Technology Productivity Capabilities
        • +Warnings, Errors, Crashed, Confirm, etc.. messages in AutoPIPE
      • +Bentley AutoPIPE Nozzle (WinNOZL)
      • +Bentley AutoPIPE Vessel (powered by Microprotol)
      • +Bentley PlantFLOW
      • +Bentley PULS
    • Multi-lingual announcement from BENTLEY TECHNICAL SUPPORT.
    • Working at Home with AutoPIPE
    • +AutoPIPE Brand Learning Resources
    • +Attend a live meeting with an AutoPIPE Analyst

     
     Questions about this article, topic, or product? Click here. 

    13. How to map a Line Number from a PCF file into AutoPIPE?

    Applies To
    Product(s): AutoPIPE
    Version(s): ALL
    Environment: N/A
    Area: Import
    Original Author: Bentley Technical Support Group
    Date Logged
    & Current Version
    Sept. 2016
    10.01.00.09

    Problem:

    When importing a PCF file, how to map the line numbers so they appear in the program? 

    Solution:

    Open the PCF translator, select Help> User Reference. Search the PDF for Line number. 

    Under Section 3: Settings is a section on Line Class and Line Numbers.

    By default:

    Pipe Properties "Line class" data is mapped from the PCF PIPING-SPEC field

    Segment "Line number" data is mapped from the PCF MISC-SPEC1 field

    Note, There are 2 methods to adjust these mapping settings:

    1. Modify the actual PCF file directly with text editing software

    2. Using AutoPIPE - Tools> Setting> PCF CAD Mapping command

    #1: Use Text Editing software:

    Open the PCFIN.MAP file using any text editing software (NotePadd++, Ultra Edit, MS Word, etc..) and make changes to these mapping settings as needed.

    #2: Use AutoPIPE command

    With AutoPIPE open, select Tools> Settings> PCF CAD Mapping command. After the dialog appears, select the PCF attribute from the drop down listing to be used when mapping to AutoPIPE.

    Question: What to do when the Line Number and or Line Class is blank after importing a PCF file?

    Answer:

    If either the "Pipe Properties Line class" or "Segment Line number are blank:

    Means PCF file does not have legitimate data in the  fields as specified in the PCFIN.MAP file:

    Avoidance:

    1. Confirm PCF file has legitimate data in the correct fields. Update original model used to create the PCF file and regenerate a corrected PCF file to be imported into AutoPIPE

    2. Redefine the PCFIN.MAP file settings to remap LINECLASS and/or LINENUMBER, fields to the correct fields in the PCF file containing this data 

    Example #1:

    After importing PCF file into AutoPIPE, Segment Line number was found to be blank. Why?

    After review, the PCFIN.MAP file had the default settings. However see the following section from the original PCF file, 


    Question:

    What is wrong with the PCF file?

    (hint: look at the PCFIN.MAP file, what is the "Line Class" and "Line Number" mapped to?)

    Answer:

    See image above, default PCF settings:

    Line Class is mapped to PIPING-SPEC

    Line number is mapped to MIS-SPEC1

    See that the  MIS-SPEC1 attribute filed is completely missing from the original PCF file. Therefor the original program that created the PCF file did not export this data field or there was no data to be exported. Regardless, problem is with the original program that created the PCF file.

    Solution #1:  Using the original software that created the PCF file, update model so MISC-SPEC1 attribute is exported to the PCF file

    Solution #2:  User can manually update the PCF file with the proper data. Example: add line number "1234-ABCD" to a pipe in the PCF file:

    Step #1, open the PCF in any word processing application (i.e NotePadd++, Ultra Edit, MS Word, etc..) 

    Step #2: Add the missing line as shown above. 

    Step #3: Save the newly updated file,

    Step #4: using PCF translator convert the updated file and re-open the new model in AutoPIPE

    Step #5: Review the input grid, Segment tab:

    Step #6: Done...now, line number is correctly imported from PCF file

    See Also

    PCF Translator FAQ & troubleshooting

    Bentley AutoPIPE

    • PCF
    • import
    • AutoPIPE
    • Line Number
    • Line Class
    • Translator
    • Share
    • History
    • More
    • Cancel
    • Mike Dattilio Created by Bentley Colleague Mike Dattilio
    • When: Fri, Sep 23 2016 11:24 AM
    • Mike Dattilio Last revision by Bentley Colleague Mike Dattilio
    • When: Fri, Dec 23 2016 1:11 PM
    • Revisions: 9
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies