181952
Tees with different material across tee legs may report inconsistent allowable values
179635
ASME NC/ND: Elbows with any flange type reports B1 factor for socket welding flange
177864
For ASME NC/ND, Reducers at Cone Angle 30 deg Reporting Wrong B1 Index
161427
B31.1: SIF is not correctly calculated for welding tees with a special consideration of crotch radius and thickness
133158
ASME B31.8: Temperature derating factor T is not used in calculation of sustained and occasional stress allowable
130551
Thermal Ratchet C4 from previously processed pipe properties may be used if current pipe properties C4 value is zero
129663
Stress indices and B2 correction factor for reducers may be calculated incorrectly
123586
Stress indices and moment of inertia may be calculated incorrectly for nodes with transition welds
115083
Default code combinations with (EXP) case considers axial force due to pressure extension only if "Inc. axial, Pcase in Sus." is checked
103060
Distributed loads are applied incorrectly to a range of piping points that are not in a connected straight line or when distributed load data is corrupted through convert point operation
91835
DNV 2012 ASD check does not take in to account maximum longitudinal stress
89211
Equivalent temperature rise dt is calculated incorrectly for HDPE pipes
139144
Temperature dependent data not updated on modifying temperature for points range
139135
Different hot modulus value not used for analysis for points on the same pipe ID
139110
Incorrect analysis results with imposed disp. or anchor movement on soil points
139109
Maximum expansion (EXP) added at moment level not associating thermal case
139105
Thermal bowing: "Instantaneous expansion coeff. for NS materials" is not used
139101
Absolute axial stress not used for calculating expansion stress for B31.3 (2012)
139095
Ce factor and exposure category is not retained in UBC wind profile dialog
Critical and High issues released in version