137118
ASME NB, NC and ND combined stress may be non-conservative for skewed pipe
137113
Tee header SIF is incorrectly used for branch in Japanese JSME 2005 code
137157
Reinforced tee B2r < 1.575 and C2r < 2.1 are incorrect for NC/ND 2003 and later
136992
Stress ISO: Metric DXF borders corrupt the file during DXF export
137074
SAM as Reverse dynamic gives zero SAM stresses in NB rev.dyn summary
137083
Pulled bend flexibility factor is conservatively set to 1.0
137084
Maximum DT1 and DT2 stress is not used for tee in pre-verification report
137040
Abutting bend stress indices are too conservative for pipe thickness < 3/16"
137069
B2 is used instead of B2' for girth BW with thickness change for Rev Dyn Summary
137071
NC/ND 2004 tee stress for reverse dynamic stress summary is conservative
137049
Flange report pressure rating class = *****
137051
Exported DXF file is corrupted
137044
Cannot run time history if a previously used THL file is not in model folder
137006
Branch Type Tee SIFs and stress indices for JSME code are using NC 2004 values
137008
Problem with entering OTHER tee for JSME code
137009
Abutting elbow C2 index is using NB 1992 girth weld C2 formula for earlier years
135993
Changing pipe material in the input grid does not update thermal expansion alpha
137144
ASME NB 1980+1982 Addenda is mislabled as ASME 1980
137002
ASME NB/NC/ND OTHER tee stress indices maybe incorrect
137003
Eqn.8 & 9 stress summary may be incorrect at plus side of tee for NC/ND 2004
135698
ASME NB Thermal Ratchet shows Delta-T1 range from last load set pair
135306
Moment summation at the tee for ASME NB ignores moment sign for second leg
135837
SAM Axial stress results are zero for ASME ND code 94 or later
135838
Incorrect MSRS analysis results when flexible joint or nozzle elements used
135841
ASME B31.3 App P option causes different results in multiple load sets
135723
Negative force/disp/gross disc. or cut short may cause incorrect stresses
135731
Tee data switched when rigid options are inserted on a branch
135796
ASME NB Equation 9 Allowable may change based on last load set pair
135799
Transition weld SIF uses thickness at plus side of the joint
135812
Some pipe properties for plus point is used for minus point for ASME NB, NC&ND
135343
Allowable Stress and Design Intensity is incorrect for few materials in ASME1986
135356
Reinforced tee B2b & B2r stress indices are set equal for NC/ND 2003-2004 code
135637
Problem with tee run moment summation for unsigned SAM cases
135638
Moment summation incorrectly applied to reverse dynamic loads for NC 1972-1980
135690
B2' = 1.5 is always used for Socket welds for NC/ND 2001 and later
135691
C2 should not be set to 1.0 when t < 0.237 in. for NC/ND 2001 and later editions
135693
ASME NB 1989 socket weld indices for Cx<=0.75tn are always used for later years
Critical and High issues released in version
Bentley AutoPIPE