B-01: Error opening RecordSet with SQL Select * from A2000A error message appears in AutoPIPE Nozzle


Applies To
Product(s):AutoPIPE Nozzle
Version(s):ALL;
Environment: N/A
Area: Error Message
Original Author:Bentley Technical Support Group
Date Logged
& Current Version
Nov. 2016
08.11.08.26

Problem:

The following message appears when entering the design temperature:

---------------------------
Warning
---------------------------

Error opening RecordSet with SQL

Select * from A2000A

---------------------------
OK
---------------------------

How to avoid this from happening?

Solution:

In conjunction with the error message appearing, the vessel nozzle image was also missing:

This issue has only been reported one time and was directly related to a missing file from the installation folder and computer permissions at the time when the software was installed.

Avoidance:

Uninstalled  AutoPIPE and AutoPIPE Nozzle from the computer. Reboot the computer, confirm user permissions for person installing software has Admin role, install AutoPIPE and AutoPIPE Nozzle as instructed. copy "ASME 2" file (request from Bentley) and Unzip the contents to this folder:

C:\Program Files (x86)\Bentley\AutoPIPE Nozzle V8i

Again, reboot the computer and try exporting nozzle loads from AutoPIPE to AutoPIPE Nozzle. \

Now everything works fine as it should.