Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
AutoPIPE
  • Product Communities
AutoPIPE
AutoPIPE Wiki 15. Why are parts of my PCF translated file into AutoPIPE missing piping or components?
    • Sign In
    • -Pipe and Vessel Stress Analysis - Wiki
      • +ADL PIPE
      • -Bentley AutoPIPE
        • +- General Information about AutoPIPE
        • +- NEW User Guide for AutoPIPE
        • +- Technical Support - AutoPIPE
        • +Batch Processing, ITS, and ATS using AutoPIPE
        • AutoPIPE QA&R program
        • +Download - Install - Release Notes - AutoPIPE
        • +File / Model Management using AutoPIPE
        • +General - AutoPIPE
        • +Graphics - AutoPIPE
        • +Grids (Input & Results) - AutoPIPE
        • -Import and Export - AutoPIPE
          • 01: What file formats can AutoPIPE Import/Export?
          • -02. Imported related issues in AutoPIPE
            • +02-01.a: Import AutoPIPE DAT model
            • +02-01.b: Issues with Importing *.NTL file into AutoPIPE
            • -02-02. AutoPIPE Translators
              • +ADLPipe Translator - AutoPIPE
              • -PCF Translator Issues for AutoPIPE
                • -01. PCF Translator FAQ & troubleshooting - AutoPIPE
                  • 0. How to install AutoPIPE's PCF translator?
                  • +01. PCF Import process aborted or crashed: what should I do?
                  • +02. PCF Translator Freezes / Not Responding / disappears from screen; now what should I do in AutoPIPE?
                  • 03. Import from Autodesk Inventor PCF files show flanges and valves as weightless “Zero Weight” components, why and how to avoid when using PCF translator in AutoPIPE?
                  • 04. "E880-1: Error in opening import batch file. File extension must be NTL" message appear when importing a PCF fiule in AutoPIPE, why and how to avoid?
                  • 05. No graphical elements found for the components after importing file into AutoPIPE
                  • 06. Branch piping is not connected to the main header pipe in converted AutoPIPE PCF file, why?
                  • 07. When importing a PCF file, all the pipe sizes are very large or small in AutoPIPE, why and how to resolve?
                  • 08. When I open the .NTL file in AutoPIPE, it truncates my pressure values, why and how to avoid?
                  • +09. Is my piping code, material, and component supported in AutoPIPE's PCF translator?
                  • 10. Imported PCF file containing branch connection O-let / olet (weldolet, elbolet, threadolet, etc..) are not connected correctly in AutoPIPE model, why and how to avoid?
                  • 11. When importing a PCf file into AutoPIPE, Status = "Incorrect Component Connection Tolerance Value", why and how to avoid?
                  • 12. When importing a PCF file, all the pipe wall thickness values are very large in AutoPIPE, why and how to resolve?
                  • 13. How to map a Line Number from a PCF file into AutoPIPE?
                  • 13. PCF Translator closes abruptly when importing a model into AutoPIPE, how to fix it?
                  • +14. Mapping examples from PCF translator to AutoPIPE?
                  • 15. Why are parts of my PCF translated file into AutoPIPE missing piping or components?
                  • 16. Why are all imported flanges from a PCF file rotated 90 deg when opened in an AutoPIPE model?
                  • 17. How to reset the PCF translator PCFin.MAP used inside of AutoPIPE?
                  • 18. Parts of my PCF translated file into AutoPIPE have piping that is not connected, why?
                  • 19. How to remove Cad Length from AutoPIPE Model?
                  • 20. Cannot select a specific item from drop down listing when importing a PCF file into AutoPIPE, why?
                  • 21. How to filter out small bore piping from being translated into an AutoPIPE model?
                  • 22. What units are used for and how is the Bend Radius calculated when importing a PCF file into AutoPIPE?
                  • 23. How are bend radius calculated when importing a PCF file into AutoPIPE?
                  • 24. PCF Imported Bends are shown as straight pipe in AutoPIPE, why/
                  • Q. How to create a PCF file for AutoPIPE?
                • 03. PCF Translator: Known Issues
                • +04. PCF Translator Version History
                • +05. Added details about AutoPIPE's PCF Translator "Tools > Settings"
                • Q. Documentation on AutoPIPE's PCF translator
              • +STRAIT Translator in AutoPIPE
            • +02-02.d Import ISM files into AutoPIPE
            • 02-03.a1: Example 1 - After import, how to fix piping that are not all connected?
            • 02-03.a2: Example 2 - After import, how to fix piping that are not all connected?
            • +02-03.b: Import MS Excel or AutoCAD DWG / DXF into AutoPIPE?
            • 02-03.c: AutoDesk REVIT into AutoPIPE
            • 02-03.e.i: PXF Import : CADAP.MAP Options
            • +02-03.e: Troubleshooting - Import AutoPlant / OpenPLANT PXF file into AutoPIPE
            • 02-03.f: Can AutoPIPE Import Bentley Microstation model information?
            • 02-03.f: Can AutoPIPE V8i Import / Export Bentley HAMMER loads?
            • +02-03.h: Import PlantSPACE model into AutoPIPE
            • 02-03.i: Import ProStructures into AutoPIPE
            • +02-03.j: Insert> Model From Bentley SACS using PipeLink or ISM
            • +02-03.k: Insert> Model From STAAD Using PipeLink
            • 02-03.l: CAD To AutoPIPE Integration
            • 02-03.m: Import CIMSteel Integration Standards (CIS/2) or STP file information into AutoPIPE
            • +02-03.n: Import / Export caesar (cii) or Areva PDMS (cii) with AutoPIPE
            • 02-03.o: Import CAE Pipe or Kpipe into AutoPIPE
            • 02-03.r: Import OpenBIM data exchange (IFC) information into AutoPIPE
            • 02-03.s: Import Pipe Net into AutoPIPE
            • 02-03.t: Import PDMS using I-Sketch, I-Run or Spoolgen into AutoPIPE
            • 02-03.u: Import PTC Creo into AutoPIPE
            • 02-03.v: Can AutoPIPE Import SAP 2000 model file?
            • 02-03.w: Import TRIMBLE PIPEDESIGNER 3D into AutoPIPE
            • 04-001: While importing or copy paste into AutoPIPE model, the node numbers are renaming automatically. How to import / copy geometry without changing the node numbers?
          • +03. Exported related issues in AutoPIPE
        • +Known Issues in AutoPIPE (Enhancements, defects, etc..)
        • +Libraries - AutoPIPE
        • +License AutoPIPE -
        • +Loads and Load Sets - AutoPIPE
        • +Localization (Non-English Language) - AutoPIPE
        • +Modeling Approaches in AutoPIPE
        • +Modules (i.e. Flange Analysis, Spring Hanger Selection, Rotating Equip, TTA) in AutoPIPE
        • +Piping codes - AutoPIPE
        • +Post Processing - AutoPIPE
        • +Printing - AutoPIPE
        • +Reports - AutoPIPE
        • Security
        • +Settings - AutoPIPE
        • +Stress Isometrics - AutoPIPE
        • +Technology Productivity Capabilities
        • +Warnings, Errors, Crashed, Confirm, etc.. messages in AutoPIPE
      • +Bentley AutoPIPE Nozzle (WinNOZL)
      • +Bentley AutoPIPE Vessel (powered by Microprotol)
      • +Bentley PlantFLOW
      • +Bentley PULS
    • Multi-lingual announcement from BENTLEY TECHNICAL SUPPORT.
    • Working at Home with AutoPIPE
    • +AutoPIPE Brand Learning Resources
    • +Attend a live meeting with an AutoPIPE Analyst

     
     Questions about this article, topic, or product? Click here. 

    15. Why are parts of my PCF translated file into AutoPIPE missing piping or components?

    Applies To
    Product(s): AutoPIPE
    Version(s): ALL;
    Environment: N/A
    Area: import
    Original Author: Bentley Technical Support Group
    Date Logged
    & Current Version
    Nov. 2016
    10.01.00.09

    Problem:

    Why are parts of my PCF translated file into AutoPIPE missing piping or components?

    Solution:

     There are multiple settings that could lead to this issue:

    1. CONTINUATION components 

    2. Pipe size was ignored by translator

    Example: 

    In the case below when reviewing the PCF file the some components had the "Continuation" properties as shown here:

    Also noted that some pipe sizes were very small.

    On PCF Translator Settings dialog the default value is 0.5 inches. Meaning that any pipe OD less that 0.5 inches are not imported.

    So to import the complete model change the Ignore OD value to 0.2 inches or even set to 0.00.

    Also on the same dialog, to import "Continuation" components, uncheck the "Ignore Continuation Components" option.

    As a result of these PCF setting changes the model is brought in with all components and pipe size available in the PCF file. 

    See Also

    PCF Translator FAQ & troubleshooting

    Bentley AutoPIPE

    • PCF
    • import
    • Continuation Components
    • AutoPIPE
    • Settings
    • Troubleshooting
    • Translator
    • Missing piping
    • Share
    • History
    • More
    • Cancel
    • Mike Dattilio Created by Bentley Colleague Mike Dattilio
    • When: Fri, Nov 18 2016 12:34 PM
    • Mike Dattilio Last revision by Bentley Colleague Mike Dattilio
    • When: Fri, Dec 23 2016 1:12 PM
    • Revisions: 3
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies