How to set up a non-code combination to print 0.3*gravity when axial displacement at a support exceeds 1/8" in thermal load case?
We apologize for the inconvenience, but there is no mechanism to have a combination set up based on a value result in another combination.
You can filter the output report based on values (see Results> Filter Criteria) , but you would still need to manually create the combination that can be enabled to be printed or not (see Tools> Combination> non-code tab> print option).
"Non-Code Comb." tab