I can not get the pressure into my calculation report. I have defined it in the pressure and temperature definition - I need to make a load combination of GR+T1+P1. Additionally I want to have the load case "hydrotest". I need restraint reactions from: P1, Combined GR+T1+P1 and hydrotest.
First create a Hydrotest case using Load>Hydrotest, and then under Loads> Static Analysis Sets> be sure to check ON: Gravity, Temperature, and "Calculate pressure extension cases, e.g. P1, P2, etc". Now create a 2nd analysis set with only Hydrotest enabled.
After the analysis sets have been defined, run the analysis and select Tools> Combinations> non-code comb tab. Note that the GRT1P1 & Hyrotest load case have already been created.
"Non-Code Comb." tab
Bentley AutoPIPE