You are currently reviewing an older revision of this page.
Stress Isometric does not create a drawing file, why? Reason #4.
Program launching a 2nd executable
Program could potentially be launching a separate executable to convert the .L00 to isometric drawing. The steps to help investigate may be:
1. Check in the model directory, is a "modelname.PCF" file generated?2. Check in the model directory, is a "modelname.apiso" file generated?
If the answer to both questions above is YES and still no Isometric drawing, then most likely the Operating System is blocking AutoPIPE to launch that separate exe process "ExecISO.exe" from installation directory.
Also, confirm using the correct isometric viewer under Isometric Manager Settings.
OPIM Stress Isometric Troubleshooting Guide
Stress Isometric does not create a drawing file, why?
Reason #1: Test using an AutoPIPE example model
Reason #2: Model's filename length is too long
Reason #3: Possible different filename and/or location
Reason #5: Prevent access to registry editing tools