Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
AutoPIPE
  • Product Communities
AutoPIPE
AutoPIPE Wiki 03. Is there another way to define current lift coefficient other than using "Insert> Xtra Data> Hydrodynamic data" in an AutoPIPE model ?
    • Sign In
    • -Pipe and Vessel Stress Analysis - Wiki
      • +ADL PIPE
      • -Bentley AutoPIPE
        • +- General Information about AutoPIPE
        • +- NEW User Guide for AutoPIPE
        • +- Technical Support - AutoPIPE
        • +Batch Processing, ITS, and ATS using AutoPIPE
        • AutoPIPE QA&R program
        • +Download - Install - Release Notes - AutoPIPE
        • +File / Model Management using AutoPIPE
        • +General - AutoPIPE
        • +Graphics - AutoPIPE
        • +Grids (Input & Results) - AutoPIPE
        • +Import and Export - AutoPIPE
        • +Known Issues in AutoPIPE (Enhancements, defects, etc..)
        • +Libraries - AutoPIPE
        • +License AutoPIPE -
        • -Loads and Load Sets - AutoPIPE
          • 01. Animate Load cases - AutoPIPE
          • 02a. Load Case Descriptions in AutoPIPE
          • +02b. Static Analysis in AutoPIPE
          • +02c. Dynamic Analysis in AutoPIPE
          • +02e. "Hydrotest" - AutoPIPE Load Case
          • +02f. "Static Earthquake" - AutoPIPE Load Case
          • +02g. "Wind" - AutoPIPE Load Case
          • +02h. "Snow Load" - AutoPIPE Load Case
          • 02i. "Thermal Bowing" - AutoPIPE Load Case
          • +02k. "Response / Force Spectrum Loads" - AutoPIPE Load Case
          • +02n. "Harmonic" - AutoPIPE Load case
          • 02p. "Time History" (M1-M50) - AutoPIPE Load Case
          • 02s. "Buoyancy" - AutoPIPE Load Case
          • -02t. "Wave" - AutoPIPE Load Case
            • 01. Can one drag and inertia coefficient per wave be added in an AutoPIPE Wave Load?
            • 02. How many nodes are needed on the pipeline to simulate the hydrodynamic forces same as defining the CD and CM in the wave load interface in an AutoPIPE model?
            • 03. Is there another way to define current lift coefficient other than using "Insert> Xtra Data> Hydrodynamic data" in an AutoPIPE model ?
            • 04. Are there any AutoPIPE sample models for incorporating wave loading with imposed displacements?
            • 05. How to define the location where wave phase angle = 0 starts at in an AutoPIPE model?
            • 06. How to input marine growth density in an AutoPIPE model?
            • 07. How to enter the Sea surface and Sea-bed floor, and current profile depths into an AutoPIPE model?
            • 08. Does Buoyancy affect piping above water elevations an below Wave Crest elevation in an AutoPIPE analysis?
          • +02u. "Fluid Transient" - AutoPIPE Load Case
          • 02v. "Steam Relief" - AutoPIPE Load Case
          • +02w. "Thermal Transient Analysis" (TTA) - AutoPIPE Load Case
          • +03a. "Gravity" - AutoPIPE Load Case
          • +03b. "Pressure" - AutoPIPE load case
          • 03c. "Temperature" - AutoPIPE load case
          • +03d. "SAM" (Seismic Anchor Analysis) - AutoPIPE load case
          • +03e. "Fatigue" - AutoPIPE load case
          • +03f. "Xtra Data" - AutoPIPE load case
          • +03g. "Occasional" - AutoPIPE load case
          • 03h. "Distributed Load" - AutoPIPE load case
          • 04. Results From Loads and Load Sets Not Answered By Piping Code Calculations
          • +05. Combination Load Cases (Tools> Combinations dialog)
          • +06. Non-linear Load Sequencing Explained
        • +Localization (Non-English Language) - AutoPIPE
        • +Modeling Approaches in AutoPIPE
        • +Modules (i.e. Flange Analysis, Spring Hanger Selection, Rotating Equip, TTA) in AutoPIPE
        • +Piping codes - AutoPIPE
        • +Post Processing - AutoPIPE
        • +Printing - AutoPIPE
        • +Reports - AutoPIPE
        • Security
        • +Settings - AutoPIPE
        • +Stress Isometrics - AutoPIPE
        • +Technology Productivity Capabilities
        • +Warnings, Errors, Crashed, Confirm, etc.. messages in AutoPIPE
      • +Bentley AutoPIPE Nozzle (WinNOZL)
      • +Bentley AutoPIPE Vessel (powered by Microprotol)
      • +Bentley PlantFLOW
      • +Bentley PULS
    • Multi-lingual announcement from BENTLEY TECHNICAL SUPPORT.
    • Working at Home with AutoPIPE
    • +AutoPIPE Brand Learning Resources
    • +Attend a live meeting with an AutoPIPE Analyst

     
     Questions about this article, topic, or product? Click here. 

    03. Is there another way to define current lift coefficient other than using "Insert> Xtra Data> Hydrodynamic data" in an AutoPIPE model ?

    Applies To
    Product(s): AutoPIPE
    Version(s): ALL;
    Environment: N/A
    Area: Wave Load case
    Original Author: Bentley Technical Support Group
    Date Logged
    & Current Version
    March. 2017
    11.00.00.22

    Problem:

    Is there another way to define current lift coefficient other than using "Insert> Xtra Data> Hydrodynamic data"?

    Solution:

    The Lift coefficient for all points is assumed zero unless identified by Insert> Xtra Data>Hydrodynamic Data.

    See Also

    "Wave" Load Case

    Bentley AutoPIPE

    • Load Case
    • Coefficient
    • AutoPIPE
    • Lift
    • Hydrodynamic
    • Current
    • Wave
    • Share
    • History
    • More
    • Cancel
    • Mike Dattilio Created by Bentley Colleague Mike Dattilio
    • When: Wed, Mar 22 2017 5:37 PM
    • Revisions: 1
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies