<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>07. Currently only Only PD 5500:2015 G2 is available, How to change the Design method / Local Loads in AutoPIPE Vessel?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36356/07-currently-only-only-pd-5500-2015-g2-is-available-how-to-change-the-design-method-local-loads-in-autopipe-vessel</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>07. Currently only Only PD 5500:2015 G2 is available, How to change the Design method / Local Loads in AutoPIPE Vessel?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36356/07-currently-only-only-pd-5500-2015-g2-is-available-how-to-change-the-design-method-local-loads-in-autopipe-vessel</link><pubDate>Thu, 20 Aug 2020 18:54:28 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:b87b2bfb-4246-4d5f-b982-29538a8522ae</guid><dc:creator>JamieP</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36356/07-currently-only-only-pd-5500-2015-g2-is-available-how-to-change-the-design-method-local-loads-in-autopipe-vessel#comments</comments><description>Current Revision posted to AutoPIPE Wiki by JamieP on 8/20/2020 6:54:28 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;width:600px;"&gt;&lt;colgroup&gt;&lt;col width="20%" /&gt; &lt;col width="80%" /&gt;&lt;/colgroup&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To &lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;AutoPIPE Vessel&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;ALL&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Settings&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Date Logged&lt;br /&gt;&amp;amp; Current Version&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Sept. 2017&lt;br /&gt;40.04.00.08&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;&lt;span style="color:#993300;text-decoration:underline;"&gt;&lt;strong&gt;Problem:&lt;/strong&gt;&lt;/span&gt;&lt;/h1&gt;
&lt;p style="margin-left:60px;"&gt;It is not possible to change Design Method / Local Load Method for Bracket support calculation. Only PD 5500:2015 G2 is still predefined and there is no possibility to change the calculation to other codes.&lt;/p&gt;
&lt;h1&gt;&lt;span style="color:#993300;text-decoration:underline;"&gt;&lt;strong&gt;Solution:&lt;/strong&gt;&lt;/span&gt;&lt;/h1&gt;
&lt;p style="padding-left:60px;"&gt;There is an issue in the UI about the Brackets (Support Properties Dialog). Only the last commercial Release is impacted (CE Update 4 - v40.04.00.08).&amp;nbsp;It is not possible to change the Local Load Method for Brackets (logged under Defect 745443).&lt;/p&gt;
&lt;h3 style="padding-left:60px;"&gt;&lt;strong&gt;Workaround:&lt;/strong&gt;&lt;/h3&gt;
&lt;p style="padding-left:60px;"&gt;The only one workaround is to open the EMVD file with a text editor (e.g. Notepad) and then find and replace these 2 values under &amp;lt;VesselSupport&amp;gt;:&lt;/p&gt;
&lt;p style="padding-left:90px;"&gt;&amp;lt;CalculationMethod&amp;gt;XX&amp;lt;/CalculationMethod&amp;gt;&lt;br /&gt; &amp;lt;CalculationMethodDate&amp;gt;YYYYMM&amp;lt;/CalculationMethodDate&amp;gt;&lt;/p&gt;
&lt;p style="padding-left:60px;"&gt;See the following list of values XX and YYYMM for each method.&lt;/p&gt;
&lt;p style="padding-left:120px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/4520007.1.png"&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-41/4520007.1.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="padding-left:60px;"&gt;This issue will be fixed for the next Update.&amp;nbsp;&lt;/p&gt;
&lt;p style="padding-left:60px;"&gt;&lt;span style="color:#ff0000;"&gt;&lt;strong&gt;Note:&lt;/strong&gt;&lt;/span&gt;&amp;nbsp;When a new model is created, data that need to be manually changed are not written, so tag must be added also.&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/bentley-autopipe.aspx"&gt;&lt;b&gt;Bentley AutoPIPE&lt;/b&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;&lt;b&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/b&gt;&lt;/h1&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AutoPIPE Vessel, PD 5500, FAQ, Local Load Method, Design Method&lt;/div&gt;
</description></item><item><title>Q. Currently only Only PD 5500:2015 G2 is available, How to change the Design method / Local Loads in AutoPIPE Vessel?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36356/07-currently-only-only-pd-5500-2015-g2-is-available-how-to-change-the-design-method-local-loads-in-autopipe-vessel/revision/6</link><pubDate>Thu, 20 Aug 2020 18:54:00 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:b87b2bfb-4246-4d5f-b982-29538a8522ae</guid><dc:creator>JamieP</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36356/07-currently-only-only-pd-5500-2015-g2-is-available-how-to-change-the-design-method-local-loads-in-autopipe-vessel#comments</comments><description>Revision 6 posted to AutoPIPE Wiki by JamieP on 8/20/2020 6:54:00 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;width:600px;"&gt;&lt;colgroup&gt;&lt;col width="20%" /&gt; &lt;col width="80%" /&gt;&lt;/colgroup&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To &lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;AutoPIPE Vessel&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;ALL&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Settings&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Date Logged&lt;br /&gt;&amp;amp; Current Version&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Sept. 2017&lt;br /&gt;40.04.00.08&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;&lt;span style="color:#993300;text-decoration:underline;"&gt;&lt;strong&gt;Problem:&lt;/strong&gt;&lt;/span&gt;&lt;/h1&gt;
&lt;p style="margin-left:60px;"&gt;It is not possible to change Design Method / Local Load Method for Bracket support calculation. Only PD 5500:2015 G2 is still predefined and there is no possibility to change the calculation to other codes.&lt;/p&gt;
&lt;h1&gt;&lt;span style="color:#993300;text-decoration:underline;"&gt;&lt;strong&gt;Solution:&lt;/strong&gt;&lt;/span&gt;&lt;/h1&gt;
&lt;p style="padding-left:60px;"&gt;There is an issue in the UI about the Brackets (Support Properties Dialog). Only the last commercial Release is impacted (CE Update 4 - v40.04.00.08).&amp;nbsp;It is not possible to change the Local Load Method for Brackets (logged under Defect 745443).&lt;/p&gt;
&lt;h3 style="padding-left:60px;"&gt;&lt;strong&gt;Workaround:&lt;/strong&gt;&lt;/h3&gt;
&lt;p style="padding-left:60px;"&gt;The only one workaround is to open the EMVD file with a text editor (e.g. Notepad) and then find and replace these 2 values under &amp;lt;VesselSupport&amp;gt;:&lt;/p&gt;
&lt;p style="padding-left:90px;"&gt;&amp;lt;CalculationMethod&amp;gt;XX&amp;lt;/CalculationMethod&amp;gt;&lt;br /&gt; &amp;lt;CalculationMethodDate&amp;gt;YYYYMM&amp;lt;/CalculationMethodDate&amp;gt;&lt;/p&gt;
&lt;p style="padding-left:60px;"&gt;See the following list of values XX and YYYMM for each method.&lt;/p&gt;
&lt;p style="padding-left:120px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/4520007.1.png"&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-41/4520007.1.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="padding-left:60px;"&gt;This issue will be fixed for the next Update.&amp;nbsp;&lt;/p&gt;
&lt;p style="padding-left:60px;"&gt;&lt;span style="color:#ff0000;"&gt;&lt;strong&gt;Note:&lt;/strong&gt;&lt;/span&gt;&amp;nbsp;When a new model is created, data that need to be manually changed are not written, so tag must be added also.&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/bentley-autopipe.aspx"&gt;&lt;b&gt;Bentley AutoPIPE&lt;/b&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;&lt;b&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/b&gt;&lt;/h1&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AutoPIPE Vessel, PD 5500, FAQ, Local Load Method, Design Method&lt;/div&gt;
</description></item><item><title>Q. Currently only Only PD 5500:2015 G2 is available, How to change the Design method / Local Loads in AutoPIPE Vessel?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36356/07-currently-only-only-pd-5500-2015-g2-is-available-how-to-change-the-design-method-local-loads-in-autopipe-vessel/revision/5</link><pubDate>Thu, 28 Jun 2018 12:54:43 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:b87b2bfb-4246-4d5f-b982-29538a8522ae</guid><dc:creator>Mike Dattilio</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36356/07-currently-only-only-pd-5500-2015-g2-is-available-how-to-change-the-design-method-local-loads-in-autopipe-vessel#comments</comments><description>Revision 5 posted to AutoPIPE Wiki by Mike Dattilio on 6/28/2018 12:54:43 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;width:600px;"&gt;&lt;colgroup&gt;&lt;col width="20%" /&gt; &lt;col width="80%" /&gt;&lt;/colgroup&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To &lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;AutoPIPE Vessel&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;ALL&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Settings&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Date Logged&lt;br /&gt;&amp;amp; Current Version&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Sept. 2017&lt;br /&gt;40.04.00.08&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;&lt;span style="color:#993300;text-decoration:underline;"&gt;&lt;strong&gt;Problem:&lt;/strong&gt;&lt;/span&gt;&lt;/h1&gt;
&lt;p style="margin-left:60px;"&gt;It is not possible to change Design Method / Local Load Method for Bracket support calculation. Only PD 5500:2015 G2 is still predefined and there is no possibility to change the calculation to other codes.&lt;/p&gt;
&lt;h1&gt;&lt;span style="color:#993300;text-decoration:underline;"&gt;&lt;strong&gt;Solution:&lt;/strong&gt;&lt;/span&gt;&lt;/h1&gt;
&lt;p style="padding-left:60px;"&gt;There is an issue in the UI about the Brackets (Support Properties Dialog). Only the last commercial Release is impacted (CE Update 4 - v40.04.00.08).&amp;nbsp;It is not possible to change the Local Load Method for Brackets (logged under Defect 745443).&lt;/p&gt;
&lt;h3 style="padding-left:60px;"&gt;&lt;strong&gt;Workaround:&lt;/strong&gt;&lt;/h3&gt;
&lt;p style="padding-left:60px;"&gt;The only one workaround is to open the EMVD file with a text editor (e.g. Notepad) and then find and replace these 2 values under &amp;lt;VesselSupport&amp;gt;:&lt;/p&gt;
&lt;p style="padding-left:90px;"&gt;&amp;lt;CalculationMethod&amp;gt;XX&amp;lt;/CalculationMethod&amp;gt;&lt;br /&gt; &amp;lt;CalculationMethodDate&amp;gt;YYYYMM&amp;lt;/CalculationMethodDate&amp;gt;&lt;/p&gt;
&lt;p style="padding-left:60px;"&gt;See the following list of values XX and YYYMM for each method.&lt;/p&gt;
&lt;p style="padding-left:120px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/4520007.1.png"&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-41/4520007.1.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="padding-left:60px;"&gt;This issue will be fixed for the next Update.&amp;nbsp;&lt;/p&gt;
&lt;p style="padding-left:60px;"&gt;&lt;span style="color:#ff0000;"&gt;&lt;strong&gt;Note:&lt;/strong&gt;&lt;/span&gt;&amp;nbsp;When a new model is created, data that need to be manually changed are not written, so tag must be added also.&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/bentley-autopipe.aspx"&gt;&lt;b&gt;Bentley AutoPIPE&lt;/b&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;&lt;b&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/b&gt;&lt;/h1&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AutoPIPE Vessel, PD 5500, FAQ, Local Load Method, Design Method&lt;/div&gt;
</description></item><item><title>Currently only Only PD 5500:2015 G2 is available, How to change the Design method / Local Loads in AutoPIPE Vessel?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36356/07-currently-only-only-pd-5500-2015-g2-is-available-how-to-change-the-design-method-local-loads-in-autopipe-vessel/revision/4</link><pubDate>Thu, 21 Sep 2017 20:06:22 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:b87b2bfb-4246-4d5f-b982-29538a8522ae</guid><dc:creator>Mike Dattilio</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36356/07-currently-only-only-pd-5500-2015-g2-is-available-how-to-change-the-design-method-local-loads-in-autopipe-vessel#comments</comments><description>Revision 4 posted to AutoPIPE Wiki by Mike Dattilio on 9/21/2017 8:06:22 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;width:600px;"&gt;&lt;colgroup&gt;&lt;col width="20%" /&gt; &lt;col width="80%" /&gt;&lt;/colgroup&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To &lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;AutoPIPE Vessel&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;ALL&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Settings&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Date Logged&lt;br /&gt;&amp;amp; Current Version&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Sept. 2017&lt;br /&gt;40.04.00.08&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;&lt;span style="color:#993300;text-decoration:underline;"&gt;&lt;strong&gt;Problem:&lt;/strong&gt;&lt;/span&gt;&lt;/h1&gt;
&lt;p style="margin-left:60px;"&gt;It is not possible to change Design Method / Local Load Method for Bracket support calculation. Only PD 5500:2015 G2 is still predefined and there is no possibility to change the calculation to other codes.&lt;/p&gt;
&lt;h1&gt;&lt;span style="color:#993300;text-decoration:underline;"&gt;&lt;strong&gt;Solution:&lt;/strong&gt;&lt;/span&gt;&lt;/h1&gt;
&lt;p style="padding-left:60px;"&gt;There is an issue in the UI about the Brackets (Support Properties Dialog). Only the last commercial Release is impacted (CE Update 4 - v40.04.00.08).&amp;nbsp;It is not possible to change the Local Load Method for Brackets (logged under Defect 745443).&lt;/p&gt;
&lt;h3 style="padding-left:60px;"&gt;&lt;strong&gt;Workaround:&lt;/strong&gt;&lt;/h3&gt;
&lt;p style="padding-left:60px;"&gt;The only one workaround is to open the EMVD file with a text editor (e.g. Notepad) and then find and replace these 2 values under &amp;lt;VesselSupport&amp;gt;:&lt;/p&gt;
&lt;p style="padding-left:90px;"&gt;&amp;lt;CalculationMethod&amp;gt;XX&amp;lt;/CalculationMethod&amp;gt;&lt;br /&gt; &amp;lt;CalculationMethodDate&amp;gt;YYYYMM&amp;lt;/CalculationMethodDate&amp;gt;&lt;/p&gt;
&lt;p style="padding-left:60px;"&gt;See the following list of values XX and YYYMM for each method.&lt;/p&gt;
&lt;p style="padding-left:120px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/4520007.1.png"&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-41/4520007.1.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="padding-left:60px;"&gt;This issue will be fixed for the next Update.&amp;nbsp;&lt;/p&gt;
&lt;p style="padding-left:60px;"&gt;&lt;span style="color:#ff0000;"&gt;&lt;strong&gt;Note:&lt;/strong&gt;&lt;/span&gt;&amp;nbsp;When a new model is created, data that need to be manually changed are not written, so tag must be added also.&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/bentley-autopipe.aspx"&gt;&lt;b&gt;Bentley AutoPIPE&lt;/b&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;&lt;b&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/b&gt;&lt;/h1&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AutoPIPE Vessel, PD 5500, FAQ, Local Load Method, Design Method&lt;/div&gt;
</description></item><item><title>Currently only Only PD 5500:2015 G2 is available, How to change the Design method / Local Loads in AutoPIPE Vessel?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36356/07-currently-only-only-pd-5500-2015-g2-is-available-how-to-change-the-design-method-local-loads-in-autopipe-vessel/revision/3</link><pubDate>Fri, 01 Sep 2017 16:40:52 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:b87b2bfb-4246-4d5f-b982-29538a8522ae</guid><dc:creator>Mike Dattilio</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36356/07-currently-only-only-pd-5500-2015-g2-is-available-how-to-change-the-design-method-local-loads-in-autopipe-vessel#comments</comments><description>Revision 3 posted to AutoPIPE Wiki by Mike Dattilio on 9/1/2017 4:40:52 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;width:600px;"&gt;&lt;colgroup&gt;&lt;col width="20%" /&gt; &lt;col width="80%" /&gt;&lt;/colgroup&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To &lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;AutoPIPE Vessel&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;ALL&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Settings&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Date Logged&lt;br /&gt;&amp;amp; Current Version&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Sept. 2017&lt;br /&gt;40.04.00.08&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;&lt;span style="color:#993300;text-decoration:underline;"&gt;&lt;strong&gt;Problem:&lt;/strong&gt;&lt;/span&gt;&lt;/h1&gt;
&lt;p style="margin-left:60px;"&gt;It is not possible to change Design Method / Local Load Method for Bracket support calculation. Only PD 5500:2015 G2 is still predefined and there is no possibility to change the calculation to other codes.&lt;/p&gt;
&lt;h1&gt;&lt;span style="color:#993300;text-decoration:underline;"&gt;&lt;strong&gt;Solution:&lt;/strong&gt;&lt;/span&gt;&lt;/h1&gt;
&lt;p style="padding-left:60px;"&gt;There is an issue in the UI about the Brackets (Support Properties Dialog). Only the last commercial Release is impacted (CE Update 4 - v40.04.00.08).&amp;nbsp;It is not possible to change the Local Load Method for Brackets (logged under Defect 745443).&lt;/p&gt;
&lt;h3 style="padding-left:60px;"&gt;&lt;strong&gt;Workaround:&lt;/strong&gt;&lt;/h3&gt;
&lt;p style="padding-left:60px;"&gt;The only one workaround is to open the EMVD file with a text editor (e.g. Notepad) and then find and replace these 2 values under &amp;lt;VesselSupport&amp;gt;:&lt;/p&gt;
&lt;p style="padding-left:90px;"&gt;&amp;lt;CalculationMethod&amp;gt;XX&amp;lt;/CalculationMethod&amp;gt;&lt;br /&gt; &amp;lt;CalculationMethodDate&amp;gt;YYYYMM&amp;lt;/CalculationMethodDate&amp;gt;&lt;/p&gt;
&lt;p style="padding-left:60px;"&gt;See the following list of values XX and YYYMM for each method.&lt;/p&gt;
&lt;p style="padding-left:120px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/4520007.1.png"&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-41/4520007.1.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="padding-left:60px;"&gt;This issue will be fixed for the next Update.&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/bentley-autopipe.aspx"&gt;&lt;b&gt;Bentley AutoPIPE&lt;/b&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;&lt;b&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/b&gt;&lt;/h1&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AutoPIPE Vessel, PD 5500, FAQ, Local Load Method, Design Method&lt;/div&gt;
</description></item><item><title>Currently only Only PD 5500:2015 G2 is available, How to change the Design method / Local Loads in AutoPIPE Vessel?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36356/07-currently-only-only-pd-5500-2015-g2-is-available-how-to-change-the-design-method-local-loads-in-autopipe-vessel/revision/2</link><pubDate>Fri, 01 Sep 2017 16:40:11 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:b87b2bfb-4246-4d5f-b982-29538a8522ae</guid><dc:creator>Mike Dattilio</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36356/07-currently-only-only-pd-5500-2015-g2-is-available-how-to-change-the-design-method-local-loads-in-autopipe-vessel#comments</comments><description>Revision 2 posted to AutoPIPE Wiki by Mike Dattilio on 9/1/2017 4:40:11 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;width:600px;"&gt;&lt;colgroup&gt;&lt;col width="20%" /&gt; &lt;col width="80%" /&gt;&lt;/colgroup&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To &lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;AutoPIPE Vessel&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;ALL&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Settings&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Date Logged&lt;br /&gt;&amp;amp; Current Version&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Sept. 2017&lt;br /&gt;40.04.00.08&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;&lt;span style="color:#993300;text-decoration:underline;"&gt;&lt;strong&gt;Problem:&lt;/strong&gt;&lt;/span&gt;&lt;/h1&gt;
&lt;p style="margin-left:60px;"&gt;It is not possible to change Design Method / Local Load Method for Bracket support calculation. Only PD 5500:2015 G2 is still predefined and there is no possibility to change the calculation to other codes.&lt;/p&gt;
&lt;h1&gt;&lt;span style="color:#993300;text-decoration:underline;"&gt;&lt;strong&gt;Solution:&lt;/strong&gt;&lt;/span&gt;&lt;/h1&gt;
&lt;p style="padding-left:60px;"&gt;There is an issue in the UI about the Brackets (Support Properties Dialog). Only the last commercial Release is impacted (CE Update 4 - v40.04.00.08).&amp;nbsp;It is not possible to change the Local Load Method for Brackets (logged under Defect 745443).&lt;/p&gt;
&lt;h3 style="padding-left:60px;"&gt;&lt;strong&gt;Workaround:&lt;/strong&gt;&lt;/h3&gt;
&lt;p style="padding-left:60px;"&gt;The only one workaround is to open the EMVD file with a text editor (e.g. Notepad) and then find and replace these 2 values under &amp;lt;VesselSupport&amp;gt;:&lt;/p&gt;
&lt;p style="padding-left:90px;"&gt;&amp;lt;CalculationMethod&amp;gt;XX&amp;lt;/CalculationMethod&amp;gt;&lt;br /&gt; &amp;lt;CalculationMethodDate&amp;gt;YYYYMM&amp;lt;/CalculationMethodDate&amp;gt;&lt;/p&gt;
&lt;p style="padding-left:60px;"&gt;See the following list of values XX and YYYMM for each method.&lt;/p&gt;
&lt;p style="padding-left:120px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/4520007.1.png"&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-41/4520007.1.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="padding-left:60px;"&gt;This issue will be fixed for the next Update.&amp;nbsp;:&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/bentley-autopipe.aspx"&gt;&lt;b&gt;Bentley AutoPIPE&lt;/b&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;&lt;b&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/b&gt;&lt;/h1&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AutoPIPE Vessel, PD 5500, FAQ, Local Load Method, Design Method&lt;/div&gt;
</description></item><item><title>Currently only Only PD 5500:2015 G2 is available, How to change the Design method / Local Loads in AutoPIPE Vessel?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36356/07-currently-only-only-pd-5500-2015-g2-is-available-how-to-change-the-design-method-local-loads-in-autopipe-vessel/revision/1</link><pubDate>Fri, 01 Sep 2017 16:30:03 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:b87b2bfb-4246-4d5f-b982-29538a8522ae</guid><dc:creator>Mike Dattilio</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36356/07-currently-only-only-pd-5500-2015-g2-is-available-how-to-change-the-design-method-local-loads-in-autopipe-vessel#comments</comments><description>Revision 1 posted to AutoPIPE Wiki by Mike Dattilio on 9/1/2017 4:30:03 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;width:600px;"&gt;&lt;colgroup&gt;&lt;col width="20%" /&gt; &lt;col width="80%" /&gt;&lt;/colgroup&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To &lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;AutoPIPE Vessel&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;ALL&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Settings&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Date Logged&lt;br /&gt;&amp;amp; Current Version&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Sept. 2017&lt;br /&gt;40.04.00.08&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;&lt;span style="color:#993300;text-decoration:underline;"&gt;&lt;strong&gt;Problem:&lt;/strong&gt;&lt;/span&gt;&lt;/h1&gt;
&lt;p style="margin-left:60px;"&gt;It is not possible to change Design Method / Local Load Method for Bracket support calculation. Only PD 5500:2015 G2 is still predefined and there is no possibility to change the calculation to other codes.&lt;/p&gt;
&lt;h1&gt;&lt;span style="color:#993300;text-decoration:underline;"&gt;&lt;strong&gt;Solution:&lt;/strong&gt;&lt;/span&gt;&lt;/h1&gt;
&lt;p style="padding-left:60px;"&gt;There is an issue in the UI about the Brackets (Support Properties Dialog). Only the last commercial Release is impacted (CE Update 4 - v40.04.00.08).&amp;nbsp;It is not possible to change the Local Load Method for Brackets (logged under Defect 745443).&lt;/p&gt;
&lt;p style="padding-left:60px;"&gt;Workaround:&lt;/p&gt;
&lt;p style="padding-left:60px;"&gt;The only one workaround is to open the EMVD file with a text editor (e.g. Notepad) and then find and replace these 2 values under &amp;lt;VesselSupport&amp;gt;:&lt;/p&gt;
&lt;p style="padding-left:90px;"&gt;&amp;lt;CalculationMethod&amp;gt;XX&amp;lt;/CalculationMethod&amp;gt;&lt;br /&gt; &amp;lt;CalculationMethodDate&amp;gt;YYYYMM&amp;lt;/CalculationMethodDate&amp;gt;&lt;/p&gt;
&lt;p style="padding-left:60px;"&gt;See the following list of values XX and YYYMM for each method.&lt;/p&gt;
&lt;p style="padding-left:120px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/4520007.1.png"&gt;&lt;img src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-41/4520007.1.png" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="padding-left:60px;"&gt;This issue will be fixed for the next Update.&amp;nbsp;:&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;