You are currently reviewing an older revision of this page.
The following message appears in AutoPIPE when running a model consistency check report:
E774-44: Equation requires more combinations to be complete.
Why and how to avoid it?
When defining a stress summary with equation 10 that includes only T1 or only 1 combination. the E774-44 error will be shown and the summary will not be printed.
Example #1:
The way to enter Amb to T1 case in the stress summary would be to enter "Zero moment case" or ambient for combination #1 and then enter T1 (or Thermal 1) of combination #2..
Example #2:
The summary entries indicate transients going from one state to another so need at least two entries to represent this. The Response 1 needs to range with T1 (Normal Operating).
Error Messages