Applies To | |
Product(s): | AutoPIPE |
Version(s): | ALL; |
Area: | Analysis |
Date Logged & Current Version | Feb. 2018 11.02.00.10 |
When piping code = ASME ND and modeling HDPE pipping with ASME CC N-755-1 (HDPE) feature enabled, does the program consider the PipeID cold allowable when calculating "S" for both Eqn. 3131.1 and Eqn.3223.1
Short answer: What are your Stress Summary settings.
The stress summary has a drop down listing for the user to select what temperature is to be used when looking up the "S" value. Possible selections from the drop down listing are:
Design - Uses Node point Design temperature when cross referencing the allowable in HDPE 2011 Table 3131-1 or table -3223-3
Ambient - Uses Node point PipeID cold allowable
MaxT - Uses Max Temperature across all load cases T1...TN when cross referencing the allowable in HDPE 2011 Table 3131-1 or table -3223-3
T1...TN - Uses selected load case temperature when cross referencing the allowable in HDPE 2011 Table 3131-1 or table -3223-3
ASME BPV-III-1-ND, AutoPIPE Nuclear Piping Code FAQ