Bentley Communities
Site
Search
User
Site
Search
User
Product Communities
AutoPIPE
AutoPIPE Wiki
Unknown Procal Release - Release 1
Sign In
-
Pipe and Vessel Stress Analysis - Wiki
+
.Bentley AutoPIPE
-
.Bentley AutoPIPE Vessel (powered by Microprotol)
+
Features and Bugs
+
General Information
+
Support Solutions and FAQ's
-
System Messages
+
"AutoPIPE Licensing" Messages displayed in AutoPIPE Vessel
+
Application Crash Messages
+
AutoPIPE Vessel Messages
+
Design and Calculations Messages
-
Error Messages
"Null IDispatch passed to AutoWrap" and "AutoCAD 2021 not registered properly" message appears when trying to generate an AutoCAD drawing using AutoPIPE, why?
Error - How to resolve "Output results required" error in AutoPIPE vessel?
Error - How to resolve "Timeout Exceeded (3600 s)" error in AutoPIPE vessel?
Error Code 032768 - Program has encountered an error and will close now
Error Code 113 - Tubesheet: modulus of elasticity at temperature missing (330 °C).... message appears in AutoPIPE AutoPIPE Vessel
Error Code 151 - Design Code required isn't part of your license (ASME)
Error Code 181 - Cone 3: should be placed between 2 shells
Error Code 182 - No face detail on flange with gasket on both side of the bolt circle
Error Code 235, 236, 237 - Floating Head (split ring): allowable stress
Error Code 243 - FLOATING HEAD (crown): modulus of elasticity at ambient temperature missing..... message appears in AutoPIPE AutoPIPE Vessel
Error Code 25 - Insufficient strength in shell/channel joint
Error Code 27 - Tubesheet Loading condition, longitudinal membrane stress
Error Code 28 - Longitudinal membrane stress in the shell exceeded
Error Code 287 - Error in formula [40*bd] for gasket according to AD B7
Error Code 29 - Equivalent stress in the tubes exceeded
Error Code 316 - PD 5500 Figure G.2.2-18 deflections of cyl. shells due to radial loads, values beyond curve boundaries
Error Code 331 - NOZZLE N1: Weld sizes are not adequate
Error Code 334 - Tubesheet: Design code required ins't part of your License (ASME)
Error Code 356 - Gasket width insufficient ( minimum=##.### mm ), the permissible gasket load is exceeded, use of a compression ring is recommended
Error Code 404 - Flange xx.xx seating pressure less than or equal to zero
Error Code 411, 412 - Nozzle AP (pad) allowable stress at temp missing, exceptional ambient allowable stress missing
Error Code 417 NOZZLE xx: Insufficient reinforcement message appears when using AutoPIPE Vessel
Error Code 425 - Floating Head (split ring/splices): insufficient thickness or gap not maintained
Error Code 490 - FLAT HEAD: number of opening > 1 ==> out of the scope (the calculation has been made with the opening giving the greater thickness). Use an other code ( EN 13445-3 or BS/PD5500 ).
Error Code 515 - FLANGE 30.02 : insufficient flange thickness (design case No. 0).
Error Code 52 - WRC 107-297: Local Load Error
Error Code 538 - ADJACENT OPENINGS (nozzles C/D): nozzles are too close to one another ( 43.785 mm < 50 mm ).
Error Code 593 - Saddle effective angle < 30Deg (blast int Max P (Corroded inertias) (Corroded Weight), revise design of vessel
Error Code 633 - The tube-to-Tubesheet joint strength is not adequate
Error Code 677 - Conical Shell (XX.XX.XX) Under Internal Pressure: U-2(g) analysis is required or provide a flare at the small junction of the conical shell (Appendix 1-5(e))
Error Code 773-Roof: Insufficient Rafters.
Error Code 77832 - Abnormal Termination message appears when starting AutoPIPE Vessel
Error Code 811 -Roof: Insufficient Girders
Error Code 885 - Tubesheet: tubesheets gasketed with shell are not possible for a fixed tubesheets heat exchanger
Error Code 89 - Allowable stress at temperature missing (95C)
Error Code 98 - Unable to design geometrical plate layout without interference
Error Code 998 - Local Loads: Beyond curve boundaries (WRC 537 cannot be applied)
Error Code-772-ROOF: Insufficient Support Column.
IDispatch::Invoke("LoadArx"=00000013) failed w/err 0x80020009
Not a valid Material Database
Unknown Procal Release - Release 1
+
Prodia2 - messages displayed in AutoPIPE Vessel
+
Prodia2.exe Messages
+
Setup Messages
+
Warning Messages
+
Video Gallery
+
ADL PIPE
+
Bentley AutoPIPE Nozzle
+
Bentley PlantFLOW
+
Bentley PULS
+
AutoPIPE Brand Learning Resources
+
Attend a live meeting with an AutoPIPE Analyst
+
Q. How to install a patch sent by Bentley AutoPIPE development team?
Unknown Procal Release - Release 1
Revision
Creation Date
Revision Author
Select All
Current Revision
Thu, Aug 27 2020 3:10 PM
JamieP
14
Revision #14
Thu, Aug 27 2020 3:10 PM
JamieP
13
Revision #13
Fri, Aug 14 2020 11:38 AM
JamieP
12
Revision #12
Thu, May 2 2019 4:35 PM
Mike Dattilio
11
Revision #11
Mon, Jul 16 2018 3:42 PM
Mike Dattilio
10
Revision #10
Mon, Jun 25 2018 2:31 PM
Mike Dattilio
9
Revision #9
Mon, Jun 25 2018 2:29 PM
Mike Dattilio
8
Revision #8
Mon, Jun 25 2018 2:26 PM
Mike Dattilio
7
Revision #7
Fri, Apr 27 2018 5:56 PM
Mike Dattilio
6
Revision #6
Thu, Apr 26 2018 11:50 AM
Mike Dattilio
5
Revision #5
Thu, Apr 26 2018 11:49 AM
Mike Dattilio
>
Compare Versions
View current version