<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>25. Why was "Use En 13445 AnnexG/En 1591" option grayed out on the Body Flange tab of the Body Flange and Cover Properties dialog  in AutoPIPE Vessel ?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38715/25-why-was-use-en-13445-annexg-en-1591-option-grayed-out-on-the-body-flange-tab-of-the-body-flange-and-cover-properties-dialog-in-autopipe-vessel</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>25. Why was "Use En 13445 AnnexG/En 1591" option grayed out on the Body Flange tab of the Body Flange and Cover Properties dialog  in AutoPIPE Vessel ?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38715/25-why-was-use-en-13445-annexg-en-1591-option-grayed-out-on-the-body-flange-tab-of-the-body-flange-and-cover-properties-dialog-in-autopipe-vessel</link><pubDate>Tue, 25 Aug 2020 18:07:58 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:26f2050f-abd9-43c6-91b4-d7ed33a275e7</guid><dc:creator>JamieP</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38715/25-why-was-use-en-13445-annexg-en-1591-option-grayed-out-on-the-body-flange-tab-of-the-body-flange-and-cover-properties-dialog-in-autopipe-vessel#comments</comments><description>Current Revision posted to AutoPIPE Wiki by JamieP on 8/25/2020 6:07:58 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;width:600px;"&gt;&lt;colgroup&gt;&lt;col width="20%" /&gt; &lt;col width="80%" /&gt;&lt;/colgroup&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To &lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;AutoPIPE Vessel&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;ALL&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Modeling&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Date Logged&lt;br /&gt;&amp;amp; Current Version&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;June 2018&lt;br /&gt;40.06.00.07&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;&lt;span style="color:#993300;text-decoration:underline;"&gt;&lt;strong&gt;Problem:&lt;/strong&gt;&lt;/span&gt;&lt;/h1&gt;
&lt;p style="margin-left:60px;"&gt;Why was &amp;quot;Use En 13445 AnnexG/En 1591&amp;quot; option grayed out on the Body Flange tab of the Body Flange and Cover Properties dialog&amp;nbsp; in AutoPIPE Vessel ?&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-41/08641.2.png" /&gt;&lt;/p&gt;
&lt;h1&gt;&lt;span style="color:#993300;text-decoration:underline;"&gt;&lt;strong&gt;Solution:&lt;/strong&gt;&lt;/span&gt;&lt;/h1&gt;
&lt;p style="padding-left:60px;"&gt;The box EN13345 annex G depends on:&amp;nbsp;&lt;/p&gt;
&lt;p style="padding-left:90px;"&gt;&lt;br /&gt;If the license (EN13345, AD2000 required) otherwise it is disabled.&lt;br /&gt;If the design code is CODAP division 1, it is disabled.&lt;br /&gt;If the attached element is a tubesheet, it is disabled&lt;br /&gt;If this is a floating head flange, bolted head flange, tubesheet, it is disabled.&lt;br /&gt;If the flange type is Integral with clamps, it is disabled&lt;br /&gt;If the gasket is both side, it is disabled.&lt;br /&gt;If the flange face of flange s Metal-Metal, it is disabled.&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p style="padding-left:30px;"&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/18651/general-modeling-questions-in-autopipe-vessel"&gt;General Modeling questions&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p style="padding-left:30px;"&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/28469/--general-information-autopipe-vessel"&gt;AutoPIPE Vessel&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p style="padding-left:30px;"&gt;&lt;a title="LEARN Server" href="http://lms.bentley.com/"&gt;&lt;b&gt;Bentley LEARN Server&lt;/b&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;&lt;b&gt;&lt;img alt=" " src="/resized-image/__size/189x60/__key/communityserver-wikis-components-files/00-00-00-00-41/pastedimage1525095480684v1.png" /&gt;&lt;/b&gt;&lt;/h1&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: En 1591, AutoPIPE Vessel, tab, Body Flange and Cover, AnnexG, EN 13445, Modeling, Grayed out, Body Flange&lt;/div&gt;
</description></item><item><title>Q. Why was "Use En 13445 AnnexG/En 1591" option grayed out on the Body Flange tab of the Body Flange and Cover Properties dialog  in AutoPIPE Vessel ?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38715/25-why-was-use-en-13445-annexg-en-1591-option-grayed-out-on-the-body-flange-tab-of-the-body-flange-and-cover-properties-dialog-in-autopipe-vessel/revision/1</link><pubDate>Fri, 01 Jun 2018 16:47:28 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:26f2050f-abd9-43c6-91b4-d7ed33a275e7</guid><dc:creator>Mike Dattilio</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38715/25-why-was-use-en-13445-annexg-en-1591-option-grayed-out-on-the-body-flange-tab-of-the-body-flange-and-cover-properties-dialog-in-autopipe-vessel#comments</comments><description>Revision 1 posted to AutoPIPE Wiki by Mike Dattilio on 6/1/2018 4:47:28 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;width:600px;"&gt;&lt;colgroup&gt;&lt;col width="20%" /&gt; &lt;col width="80%" /&gt;&lt;/colgroup&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To &lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;AutoPIPE Vessel&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;ALL&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Modeling&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Date Logged&lt;br /&gt;&amp;amp; Current Version&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;June 2018&lt;br /&gt;40.06.00.07&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;&lt;span style="color:#993300;text-decoration:underline;"&gt;&lt;strong&gt;Problem:&lt;/strong&gt;&lt;/span&gt;&lt;/h1&gt;
&lt;p style="margin-left:60px;"&gt;Why was &amp;quot;Use En 13445 AnnexG/En 1591&amp;quot; option grayed out on the Body Flange tab of the Body Flange and Cover Properties dialog&amp;nbsp; in AutoPIPE Vessel ?&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-41/08641.2.png" /&gt;&lt;/p&gt;
&lt;h1&gt;&lt;span style="color:#993300;text-decoration:underline;"&gt;&lt;strong&gt;Solution:&lt;/strong&gt;&lt;/span&gt;&lt;/h1&gt;
&lt;p style="padding-left:60px;"&gt;The box EN13345 annex G depends on:&amp;nbsp;&lt;/p&gt;
&lt;p style="padding-left:90px;"&gt;&lt;br /&gt;If the license (EN13345, AD2000 required) otherwise it is disabled.&lt;br /&gt;If the design code is CODAP division 1, it is disabled.&lt;br /&gt;If the attached element is a tubesheet, it is disabled&lt;br /&gt;If this is a floating head flange, bolted head flange, tubesheet, it is disabled.&lt;br /&gt;If the flange type is Integral with clamps, it is disabled&lt;br /&gt;If the gasket is both side, it is disabled.&lt;br /&gt;If the flange face of flange s Metal-Metal, it is disabled.&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p style="padding-left:30px;"&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/18651/general-modeling-questions-in-autopipe-vessel"&gt;General Modeling questions&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p style="padding-left:30px;"&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/28469/--general-information-autopipe-vessel"&gt;AutoPIPE Vessel&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p style="padding-left:30px;"&gt;&lt;a title="LEARN Server" href="http://lms.bentley.com/"&gt;&lt;b&gt;Bentley LEARN Server&lt;/b&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;&lt;b&gt;&lt;img alt=" " src="/resized-image/__size/189x60/__key/communityserver-wikis-components-files/00-00-00-00-41/pastedimage1525095480684v1.png" /&gt;&lt;/b&gt;&lt;/h1&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: En 1591, AutoPIPE Vessel, tab, Body Flange and Cover, AnnexG, EN 13445, Modeling, Grayed out, Body Flange&lt;/div&gt;