<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>27. Nozzle report is given as "Set-on" although "Set-in" was selected in AutoPIPE Vessel, why?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38924/27-nozzle-report-is-given-as-set-on-although-set-in-was-selected-in-autopipe-vessel-why</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>27. Nozzle report is given as "Set-on" although "Set-in" was selected in AutoPIPE Vessel, why?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38924/27-nozzle-report-is-given-as-set-on-although-set-in-was-selected-in-autopipe-vessel-why</link><pubDate>Wed, 26 Aug 2020 15:42:59 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:c9468e2d-d1ec-4b61-a044-828128b9704e</guid><dc:creator>JamieP</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38924/27-nozzle-report-is-given-as-set-on-although-set-in-was-selected-in-autopipe-vessel-why#comments</comments><description>Current Revision posted to AutoPIPE Wiki by JamieP on 8/26/2020 3:42:59 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;width:600px;"&gt;&lt;colgroup&gt;&lt;col width="20%" /&gt; &lt;col width="80%" /&gt;&lt;/colgroup&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To &lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;AutoPIPE Vessel&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;ALL&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Date Logged&lt;br /&gt;&amp;amp; Current Version&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;June 2018&lt;br /&gt;40.06.00.07&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;&lt;span style="color:#993300;text-decoration:underline;"&gt;&lt;strong&gt;Problem:&lt;/strong&gt;&lt;/span&gt;&lt;/h1&gt;
&lt;p style="margin-left:60px;"&gt;Nozzle report is given as &amp;quot;Set-on&amp;quot; although &amp;quot;Set-in&amp;quot; was selected in AutoPIPE Vessel, why?&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-41/38756640.1.png" /&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-41/24657.2.png" /&gt;&lt;/p&gt;
&lt;h1&gt;&lt;span style="color:#993300;text-decoration:underline;"&gt;&lt;strong&gt;Solution:&lt;/strong&gt;&lt;/span&gt;&lt;/h1&gt;
&lt;p style="margin-left:60px;"&gt;The Set-In / Set-On choice from the GUI has no influence on the Calculation at this time.&amp;nbsp;From the calculation, any nozzle from Air Cooler vessel are considered as Set-On. When implementing this feature, most manufacturer would never use a set-in type nozzles because the header wall (flat head) thickness was generally too thick for a full penetration weld as required for a set-in nozzle.&amp;nbsp;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;A new&amp;nbsp;enhancement&amp;nbsp;&lt;span&gt;has been logged&amp;nbsp;&lt;/span&gt;to allow the Set-In/Set-On calculation following the GUI selection (908493).&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p style="padding-left:30px;"&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/28469/--general-information-autopipe-vessel"&gt;AutoPIPE Vessel&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p style="padding-left:30px;"&gt;&lt;a title="LEARN Server" href="http://lms.bentley.com/"&gt;&lt;b&gt;Bentley LEARN Server&lt;/b&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;&lt;b&gt;&lt;img alt=" " src="/resized-image/__size/189x60/__key/communityserver-wikis-components-files/00-00-00-00-41/pastedimage1525095480684v1.png" /&gt;&lt;/b&gt;&lt;/h1&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AutoPIPE Vessel, AIR COOLER, Nozzle, Report&lt;/div&gt;
</description></item><item><title>Q. Nozzle report is given as "Set-on" although "Set-in" was selected in AutoPIPE Vessel, why?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38924/27-nozzle-report-is-given-as-set-on-although-set-in-was-selected-in-autopipe-vessel-why/revision/1</link><pubDate>Thu, 21 Jun 2018 14:17:30 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:c9468e2d-d1ec-4b61-a044-828128b9704e</guid><dc:creator>Mike Dattilio</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38924/27-nozzle-report-is-given-as-set-on-although-set-in-was-selected-in-autopipe-vessel-why#comments</comments><description>Revision 1 posted to AutoPIPE Wiki by Mike Dattilio on 6/21/2018 2:17:30 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;width:600px;"&gt;&lt;colgroup&gt;&lt;col width="20%" /&gt; &lt;col width="80%" /&gt;&lt;/colgroup&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To &lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;AutoPIPE Vessel&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;ALL&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Date Logged&lt;br /&gt;&amp;amp; Current Version&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;June 2018&lt;br /&gt;40.06.00.07&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;&lt;span style="color:#993300;text-decoration:underline;"&gt;&lt;strong&gt;Problem:&lt;/strong&gt;&lt;/span&gt;&lt;/h1&gt;
&lt;p style="margin-left:60px;"&gt;Nozzle report is given as &amp;quot;Set-on&amp;quot; although &amp;quot;Set-in&amp;quot; was selected in AutoPIPE Vessel, why?&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-41/38756640.1.png" /&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-41/24657.2.png" /&gt;&lt;/p&gt;
&lt;h1&gt;&lt;span style="color:#993300;text-decoration:underline;"&gt;&lt;strong&gt;Solution:&lt;/strong&gt;&lt;/span&gt;&lt;/h1&gt;
&lt;p style="margin-left:60px;"&gt;The Set-In / Set-On choice from the GUI has no influence on the Calculation at this time.&amp;nbsp;From the calculation, any nozzle from Air Cooler vessel are considered as Set-On. When implementing this feature, most manufacturer would never use a set-in type nozzles because the header wall (flat head) thickness was generally too thick for a full penetration weld as required for a set-in nozzle.&amp;nbsp;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;A new&amp;nbsp;enhancement&amp;nbsp;&lt;span&gt;has been logged&amp;nbsp;&lt;/span&gt;to allow the Set-In/Set-On calculation following the GUI selection (908493).&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p style="padding-left:30px;"&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/28469/--general-information-autopipe-vessel"&gt;AutoPIPE Vessel&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p style="padding-left:30px;"&gt;&lt;a title="LEARN Server" href="http://lms.bentley.com/"&gt;&lt;b&gt;Bentley LEARN Server&lt;/b&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;&lt;b&gt;&lt;img alt=" " src="/resized-image/__size/189x60/__key/communityserver-wikis-components-files/00-00-00-00-41/pastedimage1525095480684v1.png" /&gt;&lt;/b&gt;&lt;/h1&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AutoPIPE Vessel, AIR COOLER, nozzle, Report&lt;/div&gt;
</description></item></channel></rss>