Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
AutoPIPE
  • Product Communities
AutoPIPE
AutoPIPE Wiki AutoPIPE CONNECT Release Notes (11.04.00.10)
    • Sign In
    • -Pipe and Vessel Stress Analysis - Wiki
      • +ADL PIPE
      • -Bentley AutoPIPE
        • +- General Information about AutoPIPE
        • +- NEW User Guide for AutoPIPE
        • +- Technical Support - AutoPIPE
        • +Batch Processing, ITS, and ATS using AutoPIPE
        • AutoPIPE QA&R program
        • -Download - Install - Release Notes - AutoPIPE
          • +- CONNECTION Center - AutoPIPE
          • -01. Bentley AutoPIPE Release Notes
            • +01. Yearly version release notes
            • -01a. AutoPIPE CONNECT Release Notes (10.00.xx.xx - higher)
              • +AutoPIPE CONNECT Release Notes (10.00.00.10)
              • +AutoPIPE CONNECT Release Notes (10.01.00.05)
              • +AutoPIPE CONNECT Release Notes (10.01.00.08)
              • +AutoPIPE CONNECT Release Notes (10.01.00.09)
              • +AutoPIPE CONNECT Release Notes (11.00.00.22)
              • +AutoPIPE CONNECT Release Notes (11.01.00.17)
              • +AutoPIPE CONNECT Release Notes (11.01.00.23)
              • AutoPIPE CONNECT Release Notes (11.01.00.24)
              • +AutoPIPE CONNECT Release Notes (11.02.00.08)
              • +AutoPIPE CONNECT Release Notes (11.02.00.10)
              • +AutoPIPE CONNECT Release Notes (11.03.00.08)
              • -AutoPIPE CONNECT Release Notes (11.04.00.10)
                • AutoPIPE CONNECT v.11.04.00.10 - Read Me file
              • +AutoPIPE CONNECT Release Notes (12.00.00.14)
              • +AutoPIPE CONNECT Release Notes (12.00.00.16)
              • +AutoPIPE CONNECT Release Notes (12.01.00.09)
              • +AutoPIPE CONNECT Release Notes (12.01.00.10)
              • +AutoPIPE CONNECT Release Notes (12.02.00.14)
              • +AutoPIPE CONNECT Release Notes (12.03.00.17)
              • +AutoPIPE CONNECT Release Notes (12.04.00.13)
              • +AutoPIPE CONNECT Release Notes (12.04.00.14)
              • +AutoPIPE CONNECT Release Notes (12.05.00.16)
              • +AutoPIPE CONNECT Release Notes (12.06.00.48)
              • +AutoPIPE CONNECT Release Notes (12.07.00.346)
              • +AutoPIPE CONNECT Release Notes (12.08.01.010)
              • +AutoPIPE CONNECT Release Notes (12.08.02.040)
              • +AutoPIPE CONNECT Release Notes (12.08.03.015)
              • +AutoPIPE CONNECT Release Notes (12.08.04)
            • +01b. AutoPIPE V8i Release Notes (09.01.xx.xx - 09.06.xx.xx)
            • +01c. AutoPIPE XM Release Notes (08.09.xx.xx - 09.00.xx.xx)
            • +01d. AutoPIPE 2004 Release Notes (08.05.xx.xx - 08.06.xx.xx):
            • +01e. AutoPIPE 6 Release Notes (06.xx.xx)
            • 01f. AutoPIPE 05.00.11 Release Notes
            • +02a. AutoPIPE Automatic Test Set (ATS) Release Notes:
            • 04. Understanding Software Version Number Format for AutoPIPE and AutoPIPE vessel
            • Bentley AutoPIPE software notification options:
          • +02. How do I download, install, and license AutoPIPE?
          • +03. How do I Install, License, and Run AutoPIPE ATS (Automatic Test Set)?
          • 04. Installing AutoPIPE on an untested Operating System
          • +05. Hardware Related Issues - AutoPIPE
          • +06. Performing a silent installation - AutoPIPE
          • 07. Install multiple versions of AutoPIPE on the same computer
          • 09. For AutoPIPE V8i 09.05.xx.xx and lower install Bentley IEG First
          • 10. Re-associate AutoPIPE's *.DAT file extension to execute the program when double selected
          • 11. Installing and running AutoPIPE on a computer with MS Bitlocker
          • 12. Does AutoPIPE V8i rely on any external software like ActiveX, Java, Adobe Flash, dynamic link libraries etc?
          • 13. Installing AutoPIPE with AutoPLANT
          • 14. Performing a clean installation - AutoPIPE
          • 15. Re-installing AutoPIPE on a computer that needs to get rebuilt
          • 17. Updating AutoPIPE software
          • 18. Can AutoPIPE be deployed on a server to be accessed on any client machine through application or desktop virtualization ?
          • 19. How to uninstall AutoPIPE from my computer?
          • 20. AutoPIPE's installation folder is locked out or read-only?
          • 20. How to set file association when installing OPIM ?
          • 21. Can I install AutoPIPE on a VM (Virtual Machine)?
          • +22. How to install a patch sent by Bentley AutoPIPE development team?
          • Q. How to be notified when a new version of AutoPIPE has been released?
        • +File / Model Management using AutoPIPE
        • +General - AutoPIPE
        • +Graphics - AutoPIPE
        • +Grids (Input & Results) - AutoPIPE
        • +Import and Export - AutoPIPE
        • +Known Issues in AutoPIPE (Enhancements, defects, etc..)
        • +Libraries - AutoPIPE
        • +License AutoPIPE -
        • +Loads and Load Sets - AutoPIPE
        • +Localization (Non-English Language) - AutoPIPE
        • +Modeling Approaches in AutoPIPE
        • +Modules (i.e. Flange Analysis, Spring Hanger Selection, Rotating Equip, TTA) in AutoPIPE
        • +Piping codes - AutoPIPE
        • +Post Processing - AutoPIPE
        • +Printing - AutoPIPE
        • +Reports - AutoPIPE
        • Security
        • +Settings - AutoPIPE
        • +Stress Isometrics - AutoPIPE
        • +Technology Productivity Capabilities
        • +Warnings, Errors, Crashed, Confirm, etc.. messages in AutoPIPE
      • +Bentley AutoPIPE Nozzle (WinNOZL)
      • +Bentley AutoPIPE Vessel (powered by Microprotol)
      • +Bentley PlantFLOW
      • +Bentley PULS
    • Multi-lingual announcement from BENTLEY TECHNICAL SUPPORT.
    • Working at Home with AutoPIPE
    • +AutoPIPE Brand Learning Resources
    • +Attend a live meeting with an AutoPIPE Analyst

     
     Questions about this article, topic, or product? Click here. 

    AutoPIPE CONNECT Release Notes (11.04.00.10)

    Product Version

    Product  Bentley AutoPIPE CONNECT
    Version v11.04.00.10
    Language English
    Polish
    Date Posted

    English - July 2018 

    Platforms

    Microsoft Windows 7 Professional or higher (with Service Pack 1) 
    Microsoft Windows 8 Professional or higher
    Microsoft Windows 8.1 Professional or higher (with KB2919355 Update)
    Microsoft Windows 10 Professional or higher
    32 or 64 bit OS

    .NET Framework

    3.5 SP1
    4.6.1

    Licensing 

    Uses XM Licensing

    OPIM

    Does not support OPIM 10.0 or higher, highest supported version is 08.11.11.294

    Description:

    Bentley AutoPIPE CONNECT Edition v11 (v11.04.00.10) - English

    Bentley AutoPIPE CONNECT Edition is a stand-alone, engineering application for the calculation of piping stresses, fatigue stresses, fluid transient, bowing or thermal transient analysis, flange or pipe support design, and equipment nozzle loading analysis under static and dynamic loading conditions. In addition to 30+ piping codes, AutoPIPE incorporates ASME, JSME, British Standard, European, API, NEMA, ANSI, ASCE, AISC, UBC, GOST and WRC guidelines and design limits to provide a comprehensive analysis of the entire system.

    This new release provides new features, critical code updates, and enhanced product interoperability. This is a product generation update for AutoPIPE CONNECT (v11.03.00.08) which includes several bug fixes plus the following new features:

    What is New & Changed in AutoPIPE

    The following outline identifies new features and enhancements in the AutoPIPE CONNECT Edition version 11.4.. 

    Analysis

    • Flange Analysis
      • The allowable value for flange allowable stresses is now determined by the attached piping materials / piping code.
      • A warning is now issued when the calculated Bsc exceeds 1 and is not included in calculations.
      • An option has been added to substitute "B1" for the inside diameter of flange "B".
      • The flange analysis workflow has been updated to perform automatic ANSI checks for all flanges in the model.
      • External flange loads are now included in determining bolt stresses.

    Library

    • The Vendor Valve catalogs are now certified for commercial consumption.

    General

    • CONNECT Advisor is now fully integrated, including Contextual assistance, Expert Advisor, and the Ribbon command search utility. 

    Reports

      • A new check has been implemented to verify the selection of points before running a report that limits results to selected node points.
      • Export SQLite DB Input and Output Reports  [Technology Preview ] 
        • Users now have more power to create data reports with the information that is important to their teams with the new SQLite DB export capability and a custom report manager.
      • AutoPIPE Report Manager  [Technology Preview ] 
        • The query designer can be used to export custom reports to Excel with charts and pivot tables.

    Interoperability

      • Stress Isometrics with Open Plant Isometrics Manager (OPIM)
        • Separate support and anchor tags are now available to control the information to print on isometrics.
        • The default acronym for non-standard Pipe has been changed to avoid confusion with Nominal Pipe Size.
      • Read/write controls have been added to Integrated Structural Model (ISM) for better integration with Structural Analysis and Plant Design products.  [Technology Preview ] 
      • All Piping Codes and Material Libraries have been added to the PCF Translator.

    Security Release Notes

    • Not applicable to this release.

     Technology Previews - Provide users preliminary access to features currently in development but not yet ready for production. These features are provided at no additional charge to promote awareness of a feature or technology to be deployed in a future release. Users are encouraged to provide feedback and suggestions. Now all Technology previews are available in the application. These commands have '[Technology Preview]' displayed in the tool tip. 

    Detailed Readme: 

    • English

    Note: 

    1. Readme file contains limited amount of information about errors / enhancements, only QA&R members have access to detailed Error Reports

    Download, Install, and License Procedure:

    See procedure here

    Installed with AutoPIPE:

    AutoPIPE Preview Handler 01.01.04
    Bentley ADLPipe to AutoPIPE Translator 01.00.00.22
    Bentley AutoPIPE Batch File Generator 01.00.00.04
    Bentley AutoPIPE CONNECT v11

    11.04.00.10

    Bentley AutoPIPE CONNECT v11 Setup

    11.04.00.10

    Bentley AutoPIPE Nozzle V8i 08.11.08.32
    Bentley PCF to AutoPIPE Translator 01.00.00.70
    Bentley STRAIT to AutoPIPE Translator 06.00.00.15
    Connection Client 10.00.07.30
    OPIM (OpenPlant Isometric Manager) 08.11.11.285

    Validation Certificate:

    Program Name: AutoPIPE CONNECT Edition v.11.04
    Revision or Version Number: v11.04.00.10

    The above computer program has been validated by both manual and automated testing procedures as part of a comprehensive product test plan consisting of more than 700 verification and validation test cases. Software quality metrics are defined against a quality standard established by existing and historical commercial versions of the program. Bentley Systems, Inc. maintains a quality assurance program t hat controls the life cycle activities of this computer program for the design of nuclear safety related piping in compliance with ASME NQA-1-2008/ 2009a, 10 CFR Part 50 Appendix B, and 10 CFR Part 21 quality standards. Test plans and validation data are on file at Bentley's Walnut Creek, California, USA office. 

    Support for this computer program is described in Bentley SELECT Program Agreement and includes 24/7 telephone, email, and web based support along with free upgrades and updates as they become available.

    See copy of Software Validation Certificate by starting AutoPIPE, select Help Ribbon, Software Validation certificate icon. 

    See Also

    AutoPIPE CONNECT Release Notes (10.00.xx.xx - higher)

    How do I download, install, and license AutoPIPE?

    Bentley AutoPIPE

    • CONNECT Edition
    • AutoPIPE
    • release notes
    • 11.04.00.10
    • Share
    • History
    • More
    • Cancel
    • Mike Dattilio Created by Bentley Colleague Mike Dattilio
    • When: Thu, Aug 2 2018 7:40 AM
    • Mike Dattilio Last revision by Bentley Colleague Mike Dattilio
    • When: Mon, Jun 22 2020 6:12 PM
    • Revisions: 8
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies