The following message appears when exporting a WORD report from AutoPIPE
---------------------------Bentley AutoPIPE---------------------------Program failed to generate SQLite Database---------------------------OK ---------------------------
Why and how to avoid it?
Test to be sure that the program is running correctly, Perform the following:
1. Open Example model Walkthru.dat. [File> Example> Archive (*.APC)>]
2. Save file to a new folder on your desktop.
3. Analyze the model.
4. Select File> Export> SQLite database (.db)
5. A dialog should appear, enable both Input, Output, and "Open in Bentley SQLite report manger" options only. Press OK.
6. This action will create a database file in your folder on the desktop and open the report manager.
7. After the report manager opens, select the Input or Output Reports tab, move as many sub-reports from the left column to the right column and now press the green lighting bolt to generate the report. In just a few moments the report viewer will automatically appear displaying your report
8. Open the folder where the model was stored, there should be 2 new files,
a. WALKTHRU.db b. WALKTHRU_SupportReport.xlsx
a. WALKTHRU.db
b. WALKTHRU_SupportReport.xlsx
First try to recreate the output report again. If the error message appears again, after 3 tries confirm the following:
1. Check that the path name and file name does not contain non-ascii character. Try saving the model as Test.dat to a new folder on the desktop, run an analysis, and create a complete report.
2. Computer Virus protection program has AutoPIPE listed as an authorized application or exception.
3. If using AutoPIPE CONNECT v11.04.xx.xx, confirm decimal character was set to a "." dot, program will display message above where decimal character was set to "," or " ' ". Avoidance, change decimal character to a " . " (dot). For instructions to do this, google "change region decimal character" .
4. You may try to "run the application as an Admin" by right clicking on AutoPIPE icon to start the program, select Properties, and select " Run as Admin". Try the steps above.
5. Reboot the computer and try again.
Note: If the the message above appears, try again to generate a report. IF the problem continues, log a Bentley Service Request and send in your model APC file for review.