Limitation
Description
Workaround
1
Automatic split of drawing
Automatic split of drawing if all components do not fit a single drawing sheet is not available.
User can define custom break points to achieve this behavior
2
Drawing are not true to scale
OpenPlant Isometrics Manager drawings are not true to scale and the plotting is not proportional to actual size
3
Disconnected Pipeline not supported
Disconnected Pipeline is not supported similar to ISOGEN
User can select a connected pipeline manually using window selection or use View > Show > Connected Segments
4
OpenPlant Configuration Manager not integrated
OpenPlant Configuration Manager not integrated with AutoPIPE directly and will be integrated in a later version
Directions to modify
5
Data tables will always printed on right side of frame
Data tables if enabled will always be printed on right side of the drawing frame
User can change the location of data tables (reference AutoPIPEIsometrics_Advanced.pdf)
6
Dimension lines collide with symbols
Dimension lines don’t automatically avoid collisions with other symbols e.g. supports
Dimension lines can be modified in OpenPlant Isometrics Manager after the isometric drawing is produced (reference AutoPIPEIsometrics_Advanced.pdf)
Default distance of different types of dimension lines from pipeline can be modified as well
7
No control on show dimensions above or below the pipeline
User doesn’t have a control on whether to show dimensions above or below the pipeline
User can change the distance of each different type of dimension line from the pipeline
8
Drawing is not always in the center of available drawing area
Produced isometrics do not make optimal use of available white space and drawing is not always in the center of available drawing area
9
Drawing margins to control drawing area are not configurable on the fly
Drawing margins to control drawing area are set in the frame file and are not configurable on the fly
See “Modify drawing area on the border file” in Stress ISO export using OPIM Advance features.docx.
10
No option available to control the drawing number
Data table overflow is handled but the options available earlier are missing to control the drawing number etc. This can be added in a future version
In case of data table over flow the drawing number convention is [page No]/[Total Pages] like (2/4).
Right now graphics overflow was not handled but user has an option of break point to split drawing in to multiple sheets.
User can relocate drawing number (reference AutoPIPEIsometrics_Advanced.pdf)
11
Location of north arrow not configurable on fly
Location of north arrow is fixed in the frame file to upper left corner and not configurable on the fly
See “Relocate north arrow to a different position” in Stress ISO export using OPIM Advance features.docx
12
Location of drawing number is not configurable on fly
Location of drawing number is fixed in cell/frame file and not configurable on the fly
See “Relocate drawing number to a different position” in Stress ISO export using OPIM Advance features.docx
13
Annotation text font and size is not configurable on fly
Annotation text font and size is set in the frame file and not configurable on the fly
See “Change annotation Font” in Stress ISO export using OPIM Advance features.docx