AutoPIPE Version 6.03.11 for Windows Release Notes
April 11, 2003
New in 6.30:
- European piping code standard EN 13480-2002- ASME Code Update - ASME B31.3-2002 edition- ASME Code Update - ASME B31.8a-2000 addenda- ASME Code Update - ASME BPV-III-1-NC-2001 edition- ASME Code Update - ASME BPV-III-1-ND-2001 edition- Canadian Code Update - CSA-Z662-1999 edition- Added new sub-reports to model input list report- Added K-factor to hoop, shear, and total stress for the General piping code- Edit length field when modifying run, bend or tee point- Increase number of spring hanger ranges from 4 to 5- Added variable spring supports from British manufacturer QPS- Added HYDRA variable spring supports from German manufacturer Witzenmann- Added Bergen-Power variable catalog 2V spring supports- Added ANVIL/Grinnell hanger ranges triple & quadruple and sizes 00 & 000- Added hanger data from Mitsubishi, NHK, Sanwa Tekki & Yamashita- Updated Lisega hanger data to Standard Supports 2010 Catalog (10/2001)- Added flange DIN pressure ratings for 6, 64, 100, 160, 250, 320 & 400- Added ANSI B16.5a-1998, Group 1.15 flanges (A182 Gr. F91 and A217 Gr. C12A) - Option to specify relative offset of equipment suction or discharge nozzle- Option to delete rotating equipment data- Option to delete wave loading data- Updated hardware security to software security (RSSL/PSCM)
The user document numbers which corresponds to this release are:
QA26API-6.30 rev. 0 - "Tutorial" The "Acceptance Test Set" document number which corresponds to thisrelease is:
QA25API-6.30 rev. 0
Error reports are available with client participation in either the"MES" or "QA & Reporting" services. Please visit our Online Supportlogin page at...
http://www.rebis.com/support/ols/
...in order to login and generate reports. If you select "new user",submit your email address, and receive the message "we were not ableto locate you in our database"; you will need to contact us so thatyou can be added. Otherwise, once you have logged into the "OnlineSupport" page select "Error", followed by selecting the "Error Reports"tab. This will bring up a page that allows selection of the databasefor each major workgroup, and product. Select "Computer AidedEngineering", and the product you are interested in (the default is "all products"). Next, press the radio button for the "Select a Time Frame" section. The two list boxes allow selection of the time period(month/quarter and year) and format style. Report type "Simple"represents a summary set of information, where "Complex" produces allpublishable information related to the errors. The error reports canbe printed directly as displayed, or they can be pasted into a wordprocessor or spreadsheet program to allow custom formatting or permitword searching. Note that if the "View Open Items" radio button isselected, a cumulative open error report will be generated. It isimportant to recognize that this report is based on the currentcommercial release.