Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
AutoPIPE
  • Product Communities
AutoPIPE
AutoPIPE Wiki "Report Generator Error: Program Failed to merge documents" message appears in AutoPIPE when creating a report
    • Sign In
    • -Pipe and Vessel Stress Analysis - Wiki
      • -.Bentley AutoPIPE
        • +a. General Information about AutoPIPE
        • +b. NEW User Guide for AutoPIPE
        • +c. Technical Support - AutoPIPE
        • +d. Download - Install - Release Notes - AutoPIPE
        • +e. Features and Bugs in AutoPIPE
        • +f. License AutoPIPE -
        • -g. System Messages: Warnings, Errors, Crashed, Confirm, etc.. in AutoPIPE
          • "1 Interrupted Action" messages displayed while coping AutoPIPE file, why?
          • +"Alert" Messages displayed in AutoPIPE
          • +"AutoPIPE Licensing" Messages displayed in AutoPIPE
          • +"Autopipe.exe" Messages displayed in AutoPIPE
          • +"Beam Section" Messages displayed in AutoPIPE
          • -"Bentley AutoPIPE" Messages displayed in AutoPIPE
            • "Bentley OpenPLANT Isometrics Manager not found"... message appears when configuring AutoPIPE License, why?
            • "Cannot insert Component after a tee. Please insert a pipe run first"... message appears when modeling in AutoPIPE, why?
            • "Error in writing Point file.Type mismatch... " message appears in AutoPIPE , why?
            • "Error in writing Pres/Temp/PipeID file.Type mismatch... " message appears in AutoPIPE , why?
            • "Error in writing Section ID file.Type mismatch... " message appears in AutoPIPE , why?
            • "Error in writing Soil file.Type mismatch... " message appears in AutoPIPE , why?
            • "Error in writing Tee file.Type mismatch... " message appears in AutoPIPE , why?
            • "Error in writing Valve file.Type mismatch..." message appears in AutoPIPE , why?
            • "Error Opening file: xxxx.L001" message in AutoPIPE
            • "Error Writing Files...." message appears in AutoPIPE
            • "Error: Bentley CONNECT Licensing system is not installed"... message appears when configuring AutoPIPE License, why?
            • "H/D is greater than 14.0" - Bentley Message displayed in AutoPIPE
            • "Intergraph PDS translator not installed" message appears when trying to import a file into AutoPIPE.
            • "Please Analyze the Model First. The Load Table values can only be set if model analysis results exist" message appears in AutoPIPE
            • "Please select a valid test pressure case for B31.3 test pressure update." Bentley AutoPIPE message is displayed, why?
            • "Program failed to generate SQlite Database..." message appears in AutoPIPE
            • "Program has detected disconnect in selected Pipeline which is not supported..." message in AutoPIPE
            • "Query is too complex" - Bentley AutoPIPE message
            • "Report Generator Error: Program Failed to merge documents" message appears in AutoPIPE when creating a report
            • "RibbonUI.XML not found..." message appears when starting AutoPIPE, why?
            • "Ring components are not permitted in HDPE pipe system as per CC N-755-1"...message appears in AutoPIPE , why?
            • "Selection types different" message occurs when copy pasting to AutoPIPE
            • "SmartPlant translator not installed".. message appears when trying to open a PCF file in AutoPIPE, why?
            • "Stress Isometrics are only available with Nuclear or Advanced edition" - Bentley AutoPIPE message
            • "The Gasket Dimensions are not available for Gasket Type [Ring Joint] for Rating = 900 having Nominal Pipe Size of 36.000000 inch." - Bentley message in AutoPIPE
            • "The Gasket Material [SPIRAL-WOUND ALLOY WITH MINERAL FIBER FILL] is not available in the GasketMaterials Table." - Bentley message in AutoPIPE
            • "The required information is missing for this flange" - Bentley Message in AutoPIPE
            • "The value should be in range 0.010 to 10.000"... message appears when using AutoPIPE, why?
            • "Unable to generate Stress Isometric...." Bentley AutoPIPE dialog appears, why?
            • "Unable to open the asme2010.mdb database"... Bentley AutoPIPE message is displayed in the program?
            • "W88-24: Allowable based on cold yield Sy may be un-conservative" Bentley AutoPIPE message is displayed in the program?
          • +"Bentley Systems, Inc" Messages displayed in AutoPIPE
          • "Bentley.lictransmit for Windows has stopped working" message appears when using AutoPIPE program, why?
          • +"Blank" Messages displayed in AutoPIPE
          • +"Bolts*" Messages displayed in AutoPIPE
          • +"Confirm" Messages displayed in AutoPIPE
          • +"Error" messages displayed in AutoPIPE
          • +"Exception Occurred" messages displayed in AutoPIPE
          • +"Flange*" Messages displayed in AutoPIPE
          • +"Incorrect Data" messages displayed in AutoPIPE
          • +"Intel(r) Visual Fortran run-time error" messages displayed in AutoPIPE
          • +"Invalid Format" messages displayed in AutoPIPE
          • +"License Management Tool" Messages displayed in AutoPIPE
          • "Message from SofTrack" Messages displayed in AutoPIPE
          • +"Microsoft .NET Framework".. messages displayed in AutoPIPE
          • "Microsoft Visual C++ Runtime Library" message appears in AutoPIPE
          • "New Case Failed" Messages displayed in AutoPIPE
          • +"Note" Messages in AutoPIPE
          • +"PCFin" Messages displayed in AutoPIPE
          • +"Report Generator Error" Messages displayed in AutoPIPE
          • +"Reverse Segment" Messages displayed in AutoPIPE
          • +"SACS Export Error" messages displayed in AutoPIPE
          • +"Script Error" messages displayed in AutoPIPE
          • +"Text Node Editor" Messages displayed in when using OPIM from within AutoPIPE
          • "Unable to Import the Excel File..." Messages displayed in AutoPIPE
          • "Use of the selected Application is not allowed while operating offline"... message appears when using the application.
          • +"Warnings" Messages displayed in AutoPIPE
          • 01. "C:\Program Files (X86)\..." - Type mismatch dialog message appears when reviewing the results grids in AutoPIPE, why?
          • +Application Crashed or Freezes - AutoPIPE
          • AutoPIPE Report Viewer has stopped working
          • +Blank Messages displayed in AutoPIPE
          • +Issues that occur when exporting files from AutoPIPE
          • +Issues that occur when generating Reports from AutoPIPE
          • +Issues that occur when importing PXF files into AutoPIPE
          • +Known errors that occur when Installing / Uninstalling AutoPIPE
        • h. QA&R program for AutoPIPE
        • i. Security
        • +❤︎ Support Solutions and FAQ's in AutoPIPE
      • +.Bentley AutoPIPE Vessel (powered by Microprotol)
      • +ADL PIPE
      • +Bentley AutoPIPE Nozzle
      • +Bentley PlantFLOW
      • +Bentley PULS
    • +AutoPIPE Brand Learning Resources
    • +Attend a live meeting with an AutoPIPE Analyst

     
     Questions about this article, topic, or product? Click here. 

    "Report Generator Error: Program Failed to merge documents" message appears in AutoPIPE when creating a report

    Applies To
    Product(s): AutoPIPE
    Version(s): ALL;
    Area: Report
    Date Logged
    & Current Version
    Nov 2019
    12.02.00.14

    Problem:

    The following appears in AutoPIPE when exporting a model input listing:

    ---------------------------
    Bentley AutoPIPE
    ---------------------------
    Report Generator Error: Program failed to merge documents.
    ---------------------------
    OK
    ---------------------------

    Why and How to resolve?

    Solution:

    With AutoPIPE 12.02.x and lower, creating a Word Input Listing or Output Listing Report are still an Technology Preview,

    NOTE: Technology Previews provide users preliminary access to features currently in development but not yet ready for production. These features are provided at no additional charge to promote awareness of a feature or technology to be deployed in a future release. Users are encouraged to provide feedback and suggestions. To learn more about Technology Previews, please create a Service Request (be sure to include Technology Preview in the Description field).

    There is a known issue with creating reports using AutoPIPE 12.02.xx.xx, and will be fixed in 12.03.x & higher (1062240). There is no workaround at this time. 

    If you are using a  different version than 12.02, please log a Service Request referencing this WIKI page. 

    See Also

    "Bentley AutoPIPE" Messages

    Bentley AutoPIPE

    • output
    • Failed to merge
    • AutoPIPE
    • Bentley AutoPIPE
    • Report
    • Input Listing
    • Share
    • History
    • More
    • Cancel
    • Mike Dattilio Created by Bentley Colleague Mike Dattilio
    • When: Tue, Nov 26 2019 2:12 PM
    • Mike Dattilio Last revision by Bentley Colleague Mike Dattilio
    • When: Fri, Jan 10 2020 2:12 PM
    • Revisions: 3
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies