Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
AutoPIPE
  • Product Communities
AutoPIPE
AutoPIPE Wiki 09c. How to update PCF Translator Material Library listing with a new AutoPIPE User Material Library?
    • Sign In
    • -Pipe and Vessel Stress Analysis - Wiki
      • -.Bentley AutoPIPE
        • +a. General Information about AutoPIPE
        • +b. NEW User Guide for AutoPIPE
        • +c. Technical Support - AutoPIPE
        • +d. Download - Install - Release Notes - AutoPIPE
        • +e. Features and Bugs in AutoPIPE
        • +f. License AutoPIPE -
        • +g. System Messages: Warnings, Errors, Crashed, Confirm, etc.. in AutoPIPE
        • h. QA&R program for AutoPIPE
        • i. Security
        • -❤︎ Support Solutions and FAQ's in AutoPIPE
          • +Batch Processing, ITS, and ATS using AutoPIPE
          • +File / Model Management using AutoPIPE
          • +General - AutoPIPE
          • +Graphics - AutoPIPE
          • +Grids (Input & Results) - AutoPIPE
          • -Import and Export - AutoPIPE
            • +01: What file formats can AutoPIPE Import/Export?
            • -02. Imported related issues in AutoPIPE
              • +02-01.a: Import AutoPIPE DAT model
              • +02-01.b: Issues with Importing *.NTL file into AutoPIPE
              • -02-02. AutoPIPE Translators
                • +ADLPipe Translator - AutoPIPE
                • -PCF Translator Issues for AutoPIPE
                  • -01. PCF Translator FAQ & troubleshooting - AutoPIPE
                    • 0. How to install AutoPIPE's PCF translator?
                    • +01. PCF Import process aborted or crashed: what should I do?
                    • +02. PCF Translator Freezes / Not Responding / disappears from screen; now what should I do in AutoPIPE?
                    • 03. Import from Autodesk Inventor PCF files show flanges and valves as weightless “Zero Weight” components, why and how to avoid when using PCF translator in AutoPIPE?
                    • 04. "E880-1: Error in opening import batch file. File extension must be NTL" message appear when importing a PCF fiule in AutoPIPE, why and how to avoid?
                    • 05. No graphical elements found for the components after importing file into AutoPIPE
                    • 06. Branch piping is not connected to the main header pipe in converted AutoPIPE PCF file, why?
                    • 07. When importing a PCF file, all the pipe sizes are very large or small in AutoPIPE, why and how to resolve?
                    • 08. When I open the .NTL file in AutoPIPE, it truncates my pressure values, why and how to avoid?
                    • -09. Is my piping code, material, and component supported in AutoPIPE's PCF translator?
                      • 09a. How to map PCF translator material to an AutoPIPE material?
                      • 09b. How to map PCF material to an AutoPIPE material?
                      • 09c. How to update PCF Translator Material Library listing with a new AutoPIPE User Material Library?
                      • 09d. How to map PCF component to an AutoPIPE component?
                    • 10. Imported PCF file containing branch connection O-let / olet (weldolet, elbolet, threadolet, etc..) are not connected correctly in AutoPIPE model, why and how to avoid?
                    • 11. When importing a PCf file into AutoPIPE, Status = "Incorrect Component Connection Tolerance Value", why and how to avoid?
                    • 12. When importing a PCF file, all the pipe wall thickness values are very large in AutoPIPE, why and how to resolve?
                    • 13. How to map a Line Number from a PCF file into AutoPIPE?
                    • 13. PCF Translator closes abruptly when importing a model into AutoPIPE, how to fix it?
                    • +14. Mapping examples from PCF translator to AutoPIPE?
                    • 15. Why are parts of my PCF translated file into AutoPIPE missing piping or components?
                    • 16. Why are all imported flanges from a PCF file rotated 90 deg when opened in an AutoPIPE model?
                    • 17. How to reset the PCF translator PCFin.MAP used inside of AutoPIPE?
                    • 18. Parts of my PCF translated file into AutoPIPE have piping that is not connected, why?
                    • 19. How to remove Cad Length from AutoPIPE Model?
                    • 20. Cannot select a specific item from drop down listing when importing a PCF file into AutoPIPE, why?
                    • 21. How to filter out small bore piping from being translated into an AutoPIPE model?
                    • 22. What units are used for and how is the Bend Radius calculated when importing a PCF file into AutoPIPE?
                    • 23. How are bend radius calculated when importing a PCF file into AutoPIPE?
                    • 24. PCF Imported Bends are shown as straight pipe in AutoPIPE, why/
                    • 26. Flanges are not imported at correct location for flanged components. Why?
                    • Q. How to create a PCF file for AutoPIPE?
                  • 03. PCF Translator: Known Issues
                  • +04. PCF Translator Version History
                  • +05. Additional details regarding PCF Translator's tabs in AutoPIPE
                  • Q. Documentation on AutoPIPE's PCF translator
                  • Q. Is this a valid PCF file that can be imported using AutoPIPE's PCF translator?
                • +STRAIT Translator in AutoPIPE
              • +02-02.d Import ISM files into AutoPIPE
              • 02-03.a1: Example 1 - After import, how to fix piping that are not all connected?
              • 02-03.a2: Example 2 - After import, how to fix piping that are not all connected?
              • +02-03.b: Import MS Excel or AutoCAD DWG / DXF into AutoPIPE?
              • 02-03.c: AutoDesk REVIT into AutoPIPE
              • 02-03.d: Aveva E3D PSI (XML) into AutoPIPE import issues
              • 02-03.e.i: PXF Import : CADAP.MAP Options
              • +02-03.e: Troubleshooting - Import AutoPlant / OpenPLANT PXF file into AutoPIPE
              • 02-03.f: Can AutoPIPE Import Bentley Microstation model information?
              • 02-03.f: Can AutoPIPE V8i Import / Export Bentley HAMMER loads?
              • +02-03.h: Import PlantSPACE model into AutoPIPE
              • 02-03.i: Import ProStructures into AutoPIPE
              • +02-03.j: Insert> Model From Bentley SACS using PipeLink or ISM
              • +02-03.k: Insert> Model From STAAD Using PipeLink
              • 02-03.l: CAD To AutoPIPE Integration
              • 02-03.m: Import CIMSteel Integration Standards (CIS/2) or STP file information into AutoPIPE
              • +02-03.n: Import / Export caesar (cii) or Areva PDMS (cii) with AutoPIPE
              • 02-03.o: Import CAE Pipe or Kpipe into AutoPIPE
              • 02-03.r: Import OpenBIM data exchange (IFC) information into AutoPIPE
              • 02-03.s: Import Pipe Net into AutoPIPE
              • 02-03.t: Import PDMS using I-Sketch, I-Run or Spoolgen into AutoPIPE
              • 02-03.u: Import PTC Creo into AutoPIPE
              • 02-03.v: Can AutoPIPE Import SAP 2000 model file?
              • 02-03.w: Import TRIMBLE PIPEDESIGNER 3D into AutoPIPE
              • 04-001: While importing or copy paste into AutoPIPE model, the node numbers are renaming automatically. How to import / copy geometry without changing the node numbers?
            • +03. Exported related issues in AutoPIPE
          • +Libraries - AutoPIPE
          • +Loads and Load Sets - AutoPIPE
          • +Localization (Non-English Language) - AutoPIPE
          • +Modeling Approaches in AutoPIPE
          • +Modules (i.e. Flange Analysis, Spring Hanger Selection, Rotating Equip, TTA) in AutoPIPE
          • +Piping codes - AutoPIPE
          • +Post Processing - AutoPIPE
          • +Printing - AutoPIPE
          • +Reports - AutoPIPE
          • +Settings - AutoPIPE
          • +Stress Isometrics - AutoPIPE
          • +Technology Productivity Capabilities
      • +.Bentley AutoPIPE Vessel (powered by Microprotol)
      • +ADL PIPE
      • +Bentley AutoPIPE Nozzle
      • +Bentley PlantFLOW
      • +Bentley PULS
    • +AutoPIPE Brand Learning Resources
    • +Attend a live meeting with an AutoPIPE Analyst
    • +Q. How to install a patch sent by Bentley AutoPIPE development team?

     
     Questions about this article, topic, or product? Click here. 

    09c. How to update PCF Translator Material Library listing with a new AutoPIPE User Material Library?

    Applies To
    Product(s): AutoPIPE
    Version(s): All
    Area: Import
    Original Author: Bentley Technical Support Group
    Date Logged
    & Current Version
    Dec 2019
    12.01.00.14

    Problem:

    How to update PCF Translator Material Library listing with a new AutoPIPE User Material Library?

    Solution:

    After selecting a "Piping Code" on the PCF translator, the "Edition:" and "Material Library:" fields are automatically populated with default values. The user is able to modify these items as needed. However, the "Edition:" and the "Material Library:" drop down listings are filtered based on the "Piping Code" selection. If "Show All Material Libraries" is enabled, than the "Material Library:" drop down listings will show all the available selection options.

    In order to add a new item to the filtered "Edition" and "Material Library" drop down listing perform the following:

    1. Open PCFinUI.XML file using any text editor (ex. Ultra Edit, NotePad ++, etc..) 

    Note: PCFinUI.XML file is located in the same location as PCFin.MAP file above

    This file has essentially 3 different sections:  

    a. Piping Code Collection (broken into 27 subsections, 1 for each piping code in AutoPIPE)

    b. Material Library Collection

    c. Component Library Collection

    The user will be responsible for modifying the first 2 sections. 

    2. Decide what AutoPIPE Piping Code that the Material library being added will be used for (example: B313new will be used when AutoPIPE model Piping code = ASME B31.3 2016)

    3. Search file for that specific Piping Code (ex. "B31.3") and go to the first line that contains the "Search for" criteria (ex. Line 72)

    Layout:

    Line 73: Default Material library = B313-16 when Piping code = B31.3 Process

    Line 74: Default Component = AutoPIPE when Piping code = B31.3 Process

    Line 75: Default information "B31.3" written to the NTL file (CTL card) generated by the PCF translator when Piping code = B31.3 Process

    Line 76: Default Edition = 2016 when selecting Piping code = B31.3 Process

    Line 79: Edition drop down listing filtered to Year (ex. 2004)

    Line 80: If Edition = 2004, 2004 text will be written to the NTL file (CTL card) generated by the PCF translator.

    Line 81: If Piping code = B31.3 process and Edition = 2004, then default Material Library = B313-04 and will be written to the NTL file (CTL card) generated by the PCF translator

    4. Scroll down to the last Codeyear available for that specific Piping code (ex. 2016, on line 109).

      

    5. Copy lines from <CodeYear> to ,</CodeYear> (ex. Lines 108 to 112).

    6. Paste to next line (ex. creating lines 113 to 117)

    7. Update newly pasted lines with information about the new AutoPIPE Material Library to be added. 

    Example: 

    Line 114: New entry cannot match existing entries above, must be unique, In this example, the new AutoPIPE Material Library should be filtered with ASME B31.3 - 2016, therefore used "2016new". 

    Line 115: Code year (ex. 2016) written to NTL file when new Material Library (ex. B313new) is selected.

    Line 116: Name of new AutoPIPE Material Library (ex. B313new) to be added to the drop down listing and written to the NTL file 

    8. Update <MaterialLibraryCollection> section of the file, 

    a. Search PCFinUI.XML file for <MaterialLibraryCollection> and go to that location in the file.

    b. Just below "<MaterialLibraryCollection>" is the PCF translator drop down listing of the various AutoPIPE Material Libraries. Go to any location in the listing, copy an entire line, paste to next row, and modify newly pasted text with name of new library to be added. 

    Example: add B313new to the listing

    i. Highlight row 913, and use Copy command 

    ii. Create new blank row 914 and use Paste command

    iii. Update information as needed to add new material library name

    9. Save and close PCFinUI.XML file.

    10. Close and restart PCF translator.

    Note: If person making modifications to these files was meticulous and diligent, the new AutoPIPE Material Library will be filtered when selecting the correct Piping Code and Edition. And, if required the user prompted to select a new material available from material library. Review the NTL file generated by the translator to confirm selections

    Example: New material XYZ-123 was added to a new user defined AutoPIPE Material library (B313new) to be used when Piping Code = ASME B31.3 and Edition = 2016

    See Also

    Is my piping code, material, and component supported in AutoPIPE's PCF translator?

    PCF Translator FAQ & troubleshooting

    Bentley AutoPIPE

    • PCF
    • Update
    • Mapping
    • AutoPIPE
    • Library
    • material
    • Translator
    • Share
    • History
    • More
    • Cancel
    • Mike Dattilio Created by Bentley Colleague Mike Dattilio
    • When: Fri, Dec 27 2019 4:59 PM
    • Revisions: 1
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies