<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>06. In the annex you will find a file for a vessel according to ASME VIII/2 under internal and external pressure. In the design report it is stated that the opening N03.1 is not adequately reinforced for external pressure.</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51021/06-in-the-annex-you-will-find-a-file-for-a-vessel-according-to-asme-viii-2-under-internal-and-external-pressure-in-the-design-report-it-is-stated-that-the-opening-n03-1-is-not-adequately-reinforced-for-external-pressure</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>06. In the annex you will find a file for a vessel according to ASME VIII/2 under internal and external pressure. In the design report it is stated that the opening N03.1 is not adequately reinforced for external pressure.</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51021/06-in-the-annex-you-will-find-a-file-for-a-vessel-according-to-asme-viii-2-under-internal-and-external-pressure-in-the-design-report-it-is-stated-that-the-opening-n03-1-is-not-adequately-reinforced-for-external-pressure</link><pubDate>Tue, 18 Aug 2020 17:33:00 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:0a17a7c0-b200-4991-9d63-884a1b6e2b3c</guid><dc:creator>JamieP</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51021/06-in-the-annex-you-will-find-a-file-for-a-vessel-according-to-asme-viii-2-under-internal-and-external-pressure-in-the-design-report-it-is-stated-that-the-opening-n03-1-is-not-adequately-reinforced-for-external-pressure#comments</comments><description>Current Revision posted to AutoPIPE Wiki by JamieP on 8/18/2020 5:33:00 PM&lt;br /&gt;
&lt;p&gt;&lt;strong&gt;&lt;span&gt;Answer:&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;This issue was logged under TFS-D73031,&amp;nbsp;Opening under external pressure on Heat Exchanger in ASME VIII div.2: wrong calculation of allowable hoop compressive membrane stress of a cylinder.&lt;/p&gt;
&lt;p&gt;This issue has been fixed in the AutoPIPE Vessel Maintenance Release 2 (v33.02.01.08) or higher. Please confirm / update your version of AutoPIPE Vessel to&amp;nbsp;v 33.02.01.08 or higher.&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AutoPIPE Vessel, local load error message, report determining case, Output report&lt;/div&gt;
</description></item><item><title>06. In the annex you will find a file for a vessel according to ASME VIII/2 under internal and external pressure. In the design report it is stated that the opening N03.1 is not adequately reinforced for external pressure. Sallow. in this case is calculate</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51021/06-in-the-annex-you-will-find-a-file-for-a-vessel-according-to-asme-viii-2-under-internal-and-external-pressure-in-the-design-report-it-is-stated-that-the-opening-n03-1-is-not-adequately-reinforced-for-external-pressure/revision/1</link><pubDate>Tue, 18 Aug 2020 16:18:07 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:0a17a7c0-b200-4991-9d63-884a1b6e2b3c</guid><dc:creator>JamieP</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51021/06-in-the-annex-you-will-find-a-file-for-a-vessel-according-to-asme-viii-2-under-internal-and-external-pressure-in-the-design-report-it-is-stated-that-the-opening-n03-1-is-not-adequately-reinforced-for-external-pressure#comments</comments><description>Revision 1 posted to AutoPIPE Wiki by JamieP on 8/18/2020 4:18:07 PM&lt;br /&gt;
&lt;p&gt;&lt;strong&gt;&lt;span&gt;Answer:&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;This issue was logged under TFS-D73031,&amp;nbsp;Opening under external pressure on Heat Exchanger in ASME VIII div.2: wrong calculation of allowable hoop compressive membrane stress of a cylinder.&lt;/p&gt;
&lt;p&gt;This issue has been fixed in the AutoPIPE Vessel Maintenance Release 2 (v33.02.01.08) or higher. Please confirm / update your version of AutoPIPE Vessel to&amp;nbsp;v 33.02.01.08 or higher.&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AutoPIPE Vessel, local load error message, report determining case, Output report&lt;/div&gt;
</description></item></channel></rss>