<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>01. What is the formula used for hydro-test pressure calculations per CODAP Div. 1 used for Shell and Tube Heat Exchangers in AutoPIPE Vessel?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51051/01-what-is-the-formula-used-for-hydro-test-pressure-calculations-per-codap-div-1-used-for-shell-and-tube-heat-exchangers-in-autopipe-vessel</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>01. What is the formula used for hydro-test pressure calculations per CODAP Div. 1 used for Shell and Tube Heat Exchangers in AutoPIPE Vessel?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51051/01-what-is-the-formula-used-for-hydro-test-pressure-calculations-per-codap-div-1-used-for-shell-and-tube-heat-exchangers-in-autopipe-vessel</link><pubDate>Tue, 01 Aug 2023 11:09:24 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:6483431b-92f8-43ba-9e80-f716aa67b0ea</guid><dc:creator>Tanaji Gaikwad</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51051/01-what-is-the-formula-used-for-hydro-test-pressure-calculations-per-codap-div-1-used-for-shell-and-tube-heat-exchangers-in-autopipe-vessel#comments</comments><description>Current Revision posted to AutoPIPE Wiki by Tanaji Gaikwad on 8/1/2023 11:09:24 AM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;width:600px;"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To &lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;AutoPIPE Vessel&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;ALL&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Calculations&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Date Logged&lt;br /&gt;&amp;amp; Current Version&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Sept. 2017&lt;br /&gt;40.04.00.08&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;&lt;span style="color:#993300;text-decoration:underline;"&gt;&lt;strong&gt;Problem:&lt;/strong&gt;&lt;/span&gt;&lt;/h1&gt;
&lt;p style="margin-left:60px;"&gt;Formula for calculation of hydro-test pressure as per CODAP Div.1 is:&lt;/p&gt;
&lt;p style="margin-left:60px;padding-left:30px;"&gt;MAX(1.45*PS, 1.25*PSr*(fE/ft))&lt;/p&gt;
&lt;p style="margin-left:60px;padding-left:30px;"&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;Is this correct?&lt;/p&gt;
&lt;h1&gt;&lt;span style="color:#993300;text-decoration:underline;"&gt;&lt;strong&gt;Solution:&lt;/strong&gt;&lt;/span&gt;&lt;/h1&gt;
&lt;p style="margin-left:60px;"&gt;To consider the MAWP for calculation of hydro-test pressure with CODAP, select &amp;ldquo;use PED&amp;rdquo; in Design Parameter Tab.&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;span style="color:#ff0000;"&gt;&lt;strong&gt;Note:&lt;/strong&gt;&lt;/span&gt; &amp;nbsp;the MAWP cannot be determined when the design failed (insufficient thickness), in in this case the MAWP must be input.&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/bentley-autopipe.aspx"&gt;&lt;b&gt;Bentley AutoPIPE&lt;/b&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a title="LEARN Server" href="http://lms.bentley.com"&gt;&lt;b&gt;Bentley LEARN Server&lt;/b&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;&lt;b&gt;&lt;img alt=" " src="/resized-image/__size/189x60/__key/communityserver-wikis-components-files/00-00-00-00-41/pastedimage1597941076464v1.png" /&gt;&lt;/b&gt;&lt;/h1&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AutoPIPE Vessel, Shell and Tube, Div. 1, heat exchanger, Calculation, CODAP, Hydrotest&lt;/div&gt;
</description></item><item><title>01. What is the formula used for hydro-test pressure calculations per CODAP Div. 1 used for Shell and Tube Heat Exchangers in AutoPIPE Vessel?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51051/01-what-is-the-formula-used-for-hydro-test-pressure-calculations-per-codap-div-1-used-for-shell-and-tube-heat-exchangers-in-autopipe-vessel/revision/1</link><pubDate>Thu, 20 Aug 2020 16:32:43 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:6483431b-92f8-43ba-9e80-f716aa67b0ea</guid><dc:creator>JamieP</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51051/01-what-is-the-formula-used-for-hydro-test-pressure-calculations-per-codap-div-1-used-for-shell-and-tube-heat-exchangers-in-autopipe-vessel#comments</comments><description>Revision 1 posted to AutoPIPE Wiki by JamieP on 8/20/2020 4:32:43 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;width:600px;"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To &lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;AutoPIPE Vessel&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;ALL&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Calculations&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Date Logged&lt;br /&gt;&amp;amp; Current Version&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Sept. 2017&lt;br /&gt;40.04.00.08&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;&lt;span style="color:#993300;text-decoration:underline;"&gt;&lt;strong&gt;Problem:&lt;/strong&gt;&lt;/span&gt;&lt;/h1&gt;
&lt;p style="margin-left:60px;"&gt;Formula for calculation of hydro-test pressure as per CODAP Div.1 is:&lt;/p&gt;
&lt;p style="margin-left:60px;padding-left:30px;"&gt;MAX(1.45*PS, 1.25*PSr*(fE/ft))&lt;/p&gt;
&lt;p style="margin-left:60px;padding-left:30px;"&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;Is this correct?&lt;/p&gt;
&lt;h1&gt;&lt;span style="color:#993300;text-decoration:underline;"&gt;&lt;strong&gt;Solution:&lt;/strong&gt;&lt;/span&gt;&lt;/h1&gt;
&lt;p style="margin-left:60px;"&gt;To consider the MAWP for calculation of hydro-test pressure with CODAP, select &amp;ldquo;use PED&amp;rdquo; in Design Parameter Tab.&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;span style="color:#ff0000;"&gt;&lt;strong&gt;Note:&lt;/strong&gt;&lt;/span&gt; &amp;nbsp;the MAWP cannot be determined when the design failed (insufficient thickness), in in this case the MAWP must be input.&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/bentley-autopipe.aspx"&gt;&lt;b&gt;Bentley AutoPIPE&lt;/b&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a title="LEARN Server" href="http://lms.bentley.com"&gt;&lt;b&gt;Bentley LEARN Server&lt;/b&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;&lt;b&gt;&lt;img src="/resized-image/__size/189x60/__key/communityserver-wikis-components-files/00-00-00-00-41/pastedimage1597941076464v1.png" alt=" " /&gt;&lt;/b&gt;&lt;/h1&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AutoPIPE Vessel, Shell and Tube, Div. 1, heat exchanger, Calculation, CODAP, Hydrotest&lt;/div&gt;
</description></item></channel></rss>