<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>21. What can I do when I get an error by specifying a Body Flange  type of gasket when this is on vegetable fiber using Annex G for controlling the bolt stress. I noticed if I calculate the flange without annex G I’m not getting a default to choose another</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51092/21-what-can-i-do-when-i-get-an-error-by-specifying-a-body-flange-type-of-gasket-when-this-is-on-vegetable-fiber-using-annex-g-for-controlling-the-bolt-stress-i-noticed-if-i-calculate-the-flange-without-annex-g-i-m-not-getting-a-default-to-choose-another</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>21. What can I do when I get an error by specifying a Body Flange  type of gasket when this is on vegetable fiber using Annex G for controlling the bolt stress. I noticed if I calculate the flange without annex G I’m not getting a default to choose another</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51092/21-what-can-i-do-when-i-get-an-error-by-specifying-a-body-flange-type-of-gasket-when-this-is-on-vegetable-fiber-using-annex-g-for-controlling-the-bolt-stress-i-noticed-if-i-calculate-the-flange-without-annex-g-i-m-not-getting-a-default-to-choose-another</link><pubDate>Mon, 24 Aug 2020 14:21:47 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:2a5b47aa-4d94-446e-9ff8-24db448df85f</guid><dc:creator>JamieP</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51092/21-what-can-i-do-when-i-get-an-error-by-specifying-a-body-flange-type-of-gasket-when-this-is-on-vegetable-fiber-using-annex-g-for-controlling-the-bolt-stress-i-noticed-if-i-calculate-the-flange-without-annex-g-i-m-not-getting-a-default-to-choose-another#comments</comments><description>Current Revision posted to AutoPIPE Wiki by JamieP on 8/24/2020 2:21:47 PM&lt;br /&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="color:#008000;"&gt;&lt;span style="background-color:#008000;color:#ffffff;font-size:150%;"&gt;&lt;span style="font-size:x-large;"&gt;&lt;strong&gt;Answer:&lt;/strong&gt; &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="color:#008000;"&gt;This configuration was not properly considered, please consider using one of the following solutions:&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:120px;"&gt;&lt;span style="text-decoration:underline;"&gt;&lt;span style="color:#008000;text-decoration:underline;"&gt;Option #1:&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:120px;"&gt;&lt;span style="color:#008000;"&gt;Use any other type of gasket, eg.&amp;nbsp;elastomer or&amp;nbsp;PTFE. Also&amp;nbsp;increase the gasket thickness to larger than 0.00&amp;nbsp;(if you are using Design Check method you need to specify adequate dimensions).&amp;nbsp;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:180px;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-41/2388.1.png"&gt;&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-wikis-components-files/00-00-00-00-41/pastedimage1598278241183v1.png" /&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:180px;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-41/5415.2.png"&gt;&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-wikis-components-files/00-00-00-00-41/pastedimage1598278241186v2.png" /&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:120px;"&gt;&lt;span style="color:#008000;"&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:120px;"&gt;&lt;span style="color:#008000;"&gt;&lt;span style="text-decoration:underline;"&gt;Option&lt;/span&gt; #2:&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:120px;"&gt;&lt;span style="color:#008000;"&gt;This issue has been logged under TFS 69201&amp;nbsp;and will be fixed in the next version of the application (33.02.00.04 and higher).&lt;/span&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AutoPIPE Vessel, FAQ&lt;/div&gt;
</description></item><item><title>01. What can I do when I get an error by specifying a Body Flange  type of gasket when this is on vegetable fiber using Annex G for controlling the bolt stress. I noticed if I calculate the flange without annex G I’m not getting a default to choose another</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51092/21-what-can-i-do-when-i-get-an-error-by-specifying-a-body-flange-type-of-gasket-when-this-is-on-vegetable-fiber-using-annex-g-for-controlling-the-bolt-stress-i-noticed-if-i-calculate-the-flange-without-annex-g-i-m-not-getting-a-default-to-choose-another/revision/2</link><pubDate>Mon, 24 Aug 2020 14:21:19 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:2a5b47aa-4d94-446e-9ff8-24db448df85f</guid><dc:creator>JamieP</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51092/21-what-can-i-do-when-i-get-an-error-by-specifying-a-body-flange-type-of-gasket-when-this-is-on-vegetable-fiber-using-annex-g-for-controlling-the-bolt-stress-i-noticed-if-i-calculate-the-flange-without-annex-g-i-m-not-getting-a-default-to-choose-another#comments</comments><description>Revision 2 posted to AutoPIPE Wiki by JamieP on 8/24/2020 2:21:19 PM&lt;br /&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="color:#008000;"&gt;&lt;span style="background-color:#008000;color:#ffffff;font-size:150%;"&gt;&lt;span style="font-size:x-large;"&gt;&lt;strong&gt;Answer:&lt;/strong&gt; &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="color:#008000;"&gt;This configuration was not properly considered, please consider using one of the following solutions:&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:120px;"&gt;&lt;span style="text-decoration:underline;"&gt;&lt;span style="color:#008000;text-decoration:underline;"&gt;Option #1:&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:120px;"&gt;&lt;span style="color:#008000;"&gt;Use any other type of gasket, eg.&amp;nbsp;elastomer or&amp;nbsp;PTFE. Also&amp;nbsp;increase the gasket thickness to larger than 0.00&amp;nbsp;(if you are using Design Check method you need to specify adequate dimensions).&amp;nbsp;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:180px;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-41/2388.1.png"&gt;&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-wikis-components-files/00-00-00-00-41/pastedimage1598278241183v1.png" /&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:180px;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-41/5415.2.png"&gt;&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-wikis-components-files/00-00-00-00-41/pastedimage1598278241186v2.png" /&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:120px;"&gt;&lt;span style="color:#008000;"&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:120px;"&gt;&lt;span style="color:#008000;"&gt;&lt;span style="text-decoration:underline;"&gt;Option&lt;/span&gt; #2:&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:120px;"&gt;&lt;span style="color:#008000;"&gt;This issue has been logged under TFS 69201&amp;nbsp;and will be fixed in the next version of the application (33.02.00.04 and higher).&lt;/span&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AutoPIPE Vessel, FAQ, heat exchanger&lt;/div&gt;
</description></item><item><title>01. What can I do when I get an error by specifying a Body Flange  type of gasket when this is on vegetable fiber using Annex G for controlling the bolt stress. I noticed if I calculate the flange without annex G I’m not getting a default to choose another</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51092/21-what-can-i-do-when-i-get-an-error-by-specifying-a-body-flange-type-of-gasket-when-this-is-on-vegetable-fiber-using-annex-g-for-controlling-the-bolt-stress-i-noticed-if-i-calculate-the-flange-without-annex-g-i-m-not-getting-a-default-to-choose-another/revision/1</link><pubDate>Mon, 24 Aug 2020 14:10:40 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:2a5b47aa-4d94-446e-9ff8-24db448df85f</guid><dc:creator>JamieP</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51092/21-what-can-i-do-when-i-get-an-error-by-specifying-a-body-flange-type-of-gasket-when-this-is-on-vegetable-fiber-using-annex-g-for-controlling-the-bolt-stress-i-noticed-if-i-calculate-the-flange-without-annex-g-i-m-not-getting-a-default-to-choose-another#comments</comments><description>Revision 1 posted to AutoPIPE Wiki by JamieP on 8/24/2020 2:10:40 PM&lt;br /&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="color:#008000;"&gt;&lt;span style="background-color:#008000;color:#ffffff;font-size:150%;"&gt;&lt;span style="font-size:x-large;"&gt;&lt;strong&gt;Answer:&lt;/strong&gt; &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="color:#008000;"&gt;This configuration was not properly considered, please consider using one of the following solutions:&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:120px;"&gt;&lt;span style="text-decoration:underline;"&gt;&lt;span style="color:#008000;text-decoration:underline;"&gt;Option #1:&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:120px;"&gt;&lt;span style="color:#008000;"&gt;Use any other type of gasket, eg.&amp;nbsp;elastomer or&amp;nbsp;PTFE. Also&amp;nbsp;increase the gasket thickness to larger than 0.00&amp;nbsp;(if you are using Design Check method you need to specify adequate dimensions).&amp;nbsp;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:180px;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-41/2388.1.png"&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-wikis-components-files/00-00-00-00-41/pastedimage1598278241183v1.png" alt=" " /&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:180px;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-41/5415.2.png"&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-wikis-components-files/00-00-00-00-41/pastedimage1598278241186v2.png" alt=" " /&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:120px;"&gt;&lt;span style="color:#008000;"&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:120px;"&gt;&lt;span style="color:#008000;"&gt;&lt;span style="text-decoration:underline;"&gt;Option&lt;/span&gt; #2:&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:120px;"&gt;&lt;span style="color:#008000;"&gt;This issue has been logged under TFS 69201&amp;nbsp;and will be fixed in the next version of the application (33.02.00.04 and higher).&lt;/span&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;