<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>08. Can point loads or distributed loads be applied to the shells or heads?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51096/08-can-point-loads-or-distributed-loads-be-applied-to-the-shells-or-heads</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>08. Can point loads or distributed loads be applied to the shells or heads?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51096/08-can-point-loads-or-distributed-loads-be-applied-to-the-shells-or-heads</link><pubDate>Mon, 24 Aug 2020 14:28:12 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:dfbf5e78-4d35-4d13-b696-349273365353</guid><dc:creator>JamieP</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51096/08-can-point-loads-or-distributed-loads-be-applied-to-the-shells-or-heads#comments</comments><description>Current Revision posted to AutoPIPE Wiki by JamieP on 8/24/2020 2:28:12 PM&lt;br /&gt;
&lt;p style="margin-left:30px;"&gt;.to represent inner vessel supports? ..Outer Vessel stairs and platforms ? ... Pipe supports, etc..&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="background-color:#008000;color:#ffffff;font-size:150%;"&gt;&lt;strong&gt;&lt;span style="text-decoration:underline;"&gt;&lt;span style="font-size:x-large;"&gt;Answer:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="color:#008000;"&gt;Yes, there various local load options available whereby a concentrated local load (not a pure point load) can be applied via a narrow nozzle (2&amp;rdquo;) and applying radial loads (inward or outward).&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:120px;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-41/8838.4.png"&gt;&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-wikis-components-files/00-00-00-00-41/pastedimage1598278567559v1.png" /&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="color:#008000;"&gt;In main menu, selections from various local load methods (eg. PD5500, EN, WRC etc.) are made available. Here eg. WRC is being applied.&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:120px;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-41/7343.5.png"&gt;&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-wikis-components-files/00-00-00-00-41/pastedimage1598278567562v2.png" /&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="color:#008000;"&gt;If the inner vessel is structurally supported on the top from the outer vessel, it is simulated by applying an equivalent load on the nozzle (N1) radially inward eg. -10,000 daN.&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:120px;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-41/2262.6.png"&gt;&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-wikis-components-files/00-00-00-00-41/pastedimage1598278567563v3.png" /&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AutoPIPE Vessel, FAQ&lt;/div&gt;
</description></item><item><title>05. Can point loads or distributed loads be applied to the shells or heads?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51096/08-can-point-loads-or-distributed-loads-be-applied-to-the-shells-or-heads/revision/2</link><pubDate>Mon, 24 Aug 2020 14:27:48 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:dfbf5e78-4d35-4d13-b696-349273365353</guid><dc:creator>JamieP</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51096/08-can-point-loads-or-distributed-loads-be-applied-to-the-shells-or-heads#comments</comments><description>Revision 2 posted to AutoPIPE Wiki by JamieP on 8/24/2020 2:27:48 PM&lt;br /&gt;
&lt;p style="margin-left:30px;"&gt;.to represent inner vessel supports? ..Outer Vessel stairs and platforms ? ... Pipe supports, etc..&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="background-color:#008000;color:#ffffff;font-size:150%;"&gt;&lt;strong&gt;&lt;span style="text-decoration:underline;"&gt;&lt;span style="font-size:x-large;"&gt;Answer:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="color:#008000;"&gt;Yes, there various local load options available whereby a concentrated local load (not a pure point load) can be applied via a narrow nozzle (2&amp;rdquo;) and applying radial loads (inward or outward).&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:120px;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-41/8838.4.png"&gt;&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-wikis-components-files/00-00-00-00-41/pastedimage1598278567559v1.png" /&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="color:#008000;"&gt;In main menu, selections from various local load methods (eg. PD5500, EN, WRC etc.) are made available. Here eg. WRC is being applied.&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:120px;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-41/7343.5.png"&gt;&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-wikis-components-files/00-00-00-00-41/pastedimage1598278567562v2.png" /&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="color:#008000;"&gt;If the inner vessel is structurally supported on the top from the outer vessel, it is simulated by applying an equivalent load on the nozzle (N1) radially inward eg. -10,000 daN.&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:120px;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-41/2262.6.png"&gt;&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-wikis-components-files/00-00-00-00-41/pastedimage1598278567563v3.png" /&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AutoPIPE Vessel, FAQ, heat exchanger&lt;/div&gt;
</description></item><item><title>05. Can point loads or distributed loads be applied to the shells or heads?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51096/08-can-point-loads-or-distributed-loads-be-applied-to-the-shells-or-heads/revision/1</link><pubDate>Mon, 24 Aug 2020 14:16:02 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:dfbf5e78-4d35-4d13-b696-349273365353</guid><dc:creator>JamieP</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51096/08-can-point-loads-or-distributed-loads-be-applied-to-the-shells-or-heads#comments</comments><description>Revision 1 posted to AutoPIPE Wiki by JamieP on 8/24/2020 2:16:02 PM&lt;br /&gt;
&lt;p style="margin-left:30px;"&gt;.to represent inner vessel supports? ..Outer Vessel stairs and platforms ? ... Pipe supports, etc..&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="background-color:#008000;color:#ffffff;font-size:150%;"&gt;&lt;strong&gt;&lt;span style="text-decoration:underline;"&gt;&lt;span style="font-size:x-large;"&gt;Answer:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="color:#008000;"&gt;Yes, there various local load options available whereby a concentrated local load (not a pure point load) can be applied via a narrow nozzle (2&amp;rdquo;) and applying radial loads (inward or outward).&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:120px;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-41/8838.4.png"&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-wikis-components-files/00-00-00-00-41/pastedimage1598278567559v1.png" alt=" " /&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="color:#008000;"&gt;In main menu, selections from various local load methods (eg. PD5500, EN, WRC etc.) are made available. Here eg. WRC is being applied.&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:120px;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-41/7343.5.png"&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-wikis-components-files/00-00-00-00-41/pastedimage1598278567562v2.png" alt=" " /&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="color:#008000;"&gt;If the inner vessel is structurally supported on the top from the outer vessel, it is simulated by applying an equivalent load on the nozzle (N1) radially inward eg. -10,000 daN.&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:120px;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-41/2262.6.png"&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-wikis-components-files/00-00-00-00-41/pastedimage1598278567563v3.png" alt=" " /&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AutoPIPE Vessel, FAQ, heat exchanger&lt;/div&gt;