You are currently reviewing an older revision of this page.
The support at this location (ex. AB03), is a V-stop support, with the following settings:
Why when enabling the Non-linear analysis setting Ignore Friction E does the support have horizontal loadings, Zaxis: 254, Xaxis: 98?
AutoPIPE is correctly calculating the loads on the support.
Again, do not concern yourself with the individual load cases (ex. Gr, P1, E1), only consider operating conditions (ex. GRT1P1E1) in your analysis review. One should only consider individual cases when trying to understand they contribute to an operating condition results.
In this example, the individual loads case are added correctly to calculate the operating condition:
Again, why are there horizontal seismic loads on the support; 254 and -98?
AutoPIPE's analysis will release all friction loads that occurred before all analyzed seismic events when Ignore Friction E feature is enabled / turned on. In order to accomplish this, AutoPIPE will calculate the total friction force for all individual load cases as defined by the analysis load sequence (see Analysis Summary) to the specific seismic event. Then the software will apply an equal and opposite force value to essentially release the load on the support when calculating the operating condition.
Example:
Bentley AutoPIPE