Reason #0: Using the correct version of OPIM with particular version of AutoPIPE
Reason #1: Test using an AutoPIPE example model
Reason #2: Model's filename length is too long
Reason #3: Possible different filename and/or location
Reason #4: Program launching a 2nd executable
Reason #5: User Security features need to be enabled
Reason #6: Alert dialog.. not in recognized file format
Reason #7: Iso extractor path name is missing
Reason #8: No piping visible in the applications window
Reason #9: Must be using AutoPIPE Advance or AutoPIPE Nuclear license
Reason #10: Network traffic or non asci character file path
Reason #11: Incomplete components
Reason #12: Overlapping pipe
Reason #13: Carriage return in Line Number
Reason #14: Registry access was disabled for standard users
Reason #15: User SIF entered at Bend Midpoints
If the above does not resolve the issue, suggest to file a Bentley Service Request and attach the following information:
a. Files:
i. AutoPIPE APC file
ii. AutoPIPE *.isl
ii. AutoPIPE *.APISO
iv. zip file of the following folder:
C:\ProgramData\Bentley\AutoPIPE CONNECT [version]\isoextractor
b. Screen shots of Stress Isometric settings used, and errors that appear
c. Confirm numbered version of OPIM installed, use BLT, select Product Status tab, take screen shot showing OPIM version and AutoPIPE version
d. Exact steps repeat or screen recording