When I run an analysis with AutoPIPE V8i 09.06.00.15 with JSME S NC1-PPC Piping Code and edition = 2008, the following appear when I reviewing the results:
---------------------------Warning---------------------------W831-11: Seismic level includes cases not analyzed---------------------------OK---------------------------
---------------------------Note---------------------------
Seismic case number exceeds the number of defined Seismic load cases.---------------------------OK---------------------------
However, it does not appear when using year = 2005. Why is that and how to avoid?
In addition, when reviewing the code combinations,
CODE COMPLIANCE COMBINATIONS<Description>Combination Category Method Case/Combination----------------------- ----------- -------- ---------------------
**i*Szy{1} CSC Primary Abs sum *Pres
**B*Szy{1} CSC Pri+Occ Abs sum *Pres
where ** indicates that the combination includes unanalyzed load case(s)
See the following WIKI page: W831-11: Seismic level includes cases not analyzed
JSME S NC1-PPC Piping Code Calculation
Bentley AutoPIPE